What Can TENMARS TM-290 Measure? Magnetic Field, Electric Field & RF Explained Malaysia
What Can TENMARS TM-290 Measure? Magnetic Field, Electric Field & RF Explained Malaysia
When customers look for an EMF meter in Malaysia, one common misunderstanding is that every EMF meter measures the same thing.
In reality, electromagnetic fields can involve different frequency ranges and different measurement parameters.
The TENMARS TM-290 Multi-Field EMF Meter is designed to measure three major categories:
Low-frequency magnetic field
Low-frequency electric field
RF electromagnetic field
Understanding the difference between these measurements can help users choose the correct instrument and interpret measurements more appropriately.
1. What Is Magnetic Field Measurement?
Electrical equipment operating from AC power can produce low-frequency magnetic fields.
The TENMARS TM-290 measures low-frequency magnetic fields at 50/60 Hz, which corresponds to common mains power frequencies.
Its magnetic-field ranges are:
or
2 / 20 / 200 µT
The TM-290 uses three-axis X, Y and Z measurement.
This is useful because magnetic-field readings can vary depending on the direction and orientation of the field.
Instead of relying only on a single measurement axis, users can check the X, Y and Z components as well as the combined reading.
Where Might You Check Magnetic Fields?
Typical locations include:
Electrical panels
Distribution equipment
Transformers
Motors
Pumps
Industrial machines
Power supplies
Electrical rooms
Building electrical installations
For example, a maintenance technician may take measurements at several distances from an electrical panel to observe how the magnetic-field reading changes.
2. What Is Electric Field Measurement?
Electric fields are another component associated with electrical installations and energized equipment.
The TENMARS TM-290 measures low-frequency electric fields at 50/60 Hz.
Measurement range:
50 V/m to 2000 V/m
Electric-field measurement may be useful when investigating areas around:
Electrical wiring
Powered equipment
Electrical installations
Electrical distribution areas
Office electrical equipment
Industrial equipment
Magnetic field and electric field are related electromagnetic phenomena, but they are not interchangeable measurements.
This is why having both functions in one instrument can be useful during an EMF investigation.
3. What Is RF Measurement?
RF stands for Radio Frequency.
Unlike the 50/60 Hz measurements used for the TM-290's low-frequency electric and magnetic field functions, RF measurements involve much higher frequencies.
The TENMARS TM-290 covers an RF frequency range of:
50 MHz to 10 GHz
Its RF measurement range is:
0.2 µW/m² to 554.6 mW/m²
The meter provides several selectable RF units, including:
µW/m²
mW/m²
µW/cm²
mV/m
V/m
mA/m
dBm
This function can be used for general RF field investigation around compatible sources within the meter's specified frequency range.
What Types of RF Sources Can Be Investigated?
Depending on the operating frequency of the source, RF investigation may include areas around:
Wi-Fi equipment
Wireless access points
Communication equipment
RF transmitters
Wireless devices
Commercial communication installations
Selected telecommunication environments
Always confirm that the frequency being investigated falls within the instrument's 50 MHz–10 GHz RF measurement range.
Magnetic Field vs Electric Field vs RF
The easiest way to understand the TM-290 is to consider the source you are investigating.
Electrical power equipment
You may be interested in the 50/60 Hz magnetic and electric fields.
Wireless or communication equipment
You may be more interested in the RF field.
Unknown EMF source
You may need to investigate more than one field type before understanding where the reading is coming from.
This is where a multi-field instrument can be particularly convenient.
Why a 3-in-1 EMF Meter Can Be Useful
Suppose you enter an equipment room containing:
Electrical distribution panels
UPS equipment
Power cables
Network equipment
Wireless communication devices
There may be several potential electromagnetic sources in the same environment.
Using an instrument that measures only magnetic fields will not provide RF measurement.
Similarly, an RF-only meter does not replace a low-frequency magnetic-field meter.
The TENMARS TM-290 combines all three measurement functions in one handheld meter:
Magnetic Field + Electric Field + RF
This makes it useful for preliminary investigation and general field checking where multiple EMF sources may be present.
Example: Checking an Office
In an office, a user may want to investigate several locations.
For example:
Near electrical equipment
Check low-frequency magnetic and electric fields.
Near an electrical distribution panel
Check 50/60 Hz magnetic-field levels at different distances.
Near Wi-Fi equipment
Use the RF measurement function where the source frequency falls within the meter's specified RF range.
At a workstation
Compare readings at different locations rather than relying on only one measurement point.
This approach provides more useful information than taking a single reading without identifying the type of field being measured.
Example: Checking a Factory
Factories can contain many electrical and electronic systems.
Possible investigation points include:
Motors
Control panels
Distribution boards
Electrical rooms
Production machinery
Wireless communication equipment
The TM-290 allows technicians to switch between the appropriate measurement functions according to the source being investigated.
Example: Data Centre EMF Investigation
A data centre can contain both power infrastructure and communication equipment.
Potential investigation areas may include:
Electrical distribution areas
UPS systems
Power equipment
Server areas
Network infrastructure
Wireless equipment
The TM-290 can therefore be used as a portable instrument for general EMF investigation across different types of sources.
It is important, however, to understand what parameter is being measured rather than treating every displayed value as the same type of EMF reading.
Why Measurement Units Matter
Different EMF parameters use different units.
For example:
Magnetic field: mG or µT
Electric field: V/m
RF field: may be displayed in units such as µW/m², mW/m² or V/m
These units represent different physical quantities.
Therefore, a value shown in µT should not be directly compared numerically with a value shown in V/m or mW/m².
Understanding the measurement mode and unit is essential when recording or interpreting results.
TENMARS TM-290 for EMF Investigation in Malaysia
The TENMARS TM-290 is especially useful when users need more than a basic single-function EMF meter.
Its three measurement capabilities cover:
50/60 Hz Magnetic Field
50/60 Hz Electric Field
50 MHz–10 GHz RF Field
This combination makes the instrument suitable for general EMF investigation in factories, offices, commercial buildings, electrical facilities, data centres and other environments where different electromagnetic sources may be present.
For TENMARS TM-290 availability, quotation or technical enquiries in Malaysia, contact:
MTM Precision Sdn Bhd
Puchong Showroom & Service Centre
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Serving customers throughout Malaysia, including Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.
20 Sep 2026