What Can TENMARS TM-290 Measure? Magnetic Field, Electric Field & RF Explained Malaysia

What Can TENMARS TM-290 Measure? Magnetic Field, Electric Field & RF Explained Malaysia

 

When customers look for an EMF meter in Malaysia, one common misunderstanding is that every EMF meter measures the same thing.

 

In reality, electromagnetic fields can involve different frequency ranges and different measurement parameters.

 

The TENMARS TM-290 Multi-Field EMF Meter is designed to measure three major categories:

 

Low-frequency magnetic field

 

Low-frequency electric field

 

RF electromagnetic field

 

Understanding the difference between these measurements can help users choose the correct instrument and interpret measurements more appropriately.

 

1. What Is Magnetic Field Measurement?

 

Electrical equipment operating from AC power can produce low-frequency magnetic fields.

 

The TENMARS TM-290 measures low-frequency magnetic fields at 50/60 Hz, which corresponds to common mains power frequencies.

 

Its magnetic-field ranges are:

 

20 / 200 / 2000 mG

 

or

 

2 / 20 / 200 µT

 

The TM-290 uses three-axis X, Y and Z measurement.

 

This is useful because magnetic-field readings can vary depending on the direction and orientation of the field.

 

Instead of relying only on a single measurement axis, users can check the X, Y and Z components as well as the combined reading.

 

Where Might You Check Magnetic Fields?

 

Typical locations include:

 

Electrical panels

 

Distribution equipment

 

Transformers

 

Motors

 

Pumps

 

Industrial machines

 

Power supplies

 

Electrical rooms

 

Building electrical installations

 

For example, a maintenance technician may take measurements at several distances from an electrical panel to observe how the magnetic-field reading changes.

 

2. What Is Electric Field Measurement?

 

Electric fields are another component associated with electrical installations and energized equipment.

 

The TENMARS TM-290 measures low-frequency electric fields at 50/60 Hz.

 

Measurement range:

 

50 V/m to 2000 V/m

 

Electric-field measurement may be useful when investigating areas around:

 

Electrical wiring

 

Powered equipment

 

Electrical installations

 

Electrical distribution areas

 

Office electrical equipment

 

Industrial equipment

 

Magnetic field and electric field are related electromagnetic phenomena, but they are not interchangeable measurements.

 

This is why having both functions in one instrument can be useful during an EMF investigation.

 

3. What Is RF Measurement?

 

RF stands for Radio Frequency.

 

Unlike the 50/60 Hz measurements used for the TM-290's low-frequency electric and magnetic field functions, RF measurements involve much higher frequencies.

 

The TENMARS TM-290 covers an RF frequency range of:

 

50 MHz to 10 GHz

 

Its RF measurement range is:

 

0.2 µW/m² to 554.6 mW/m²

 

The meter provides several selectable RF units, including:

 

µW/m²

 

mW/m²

 

µW/cm²

 

mV/m

 

V/m

 

mA/m

 

dBm

 

This function can be used for general RF field investigation around compatible sources within the meter's specified frequency range.

 

What Types of RF Sources Can Be Investigated?

 

Depending on the operating frequency of the source, RF investigation may include areas around:

 

Wi-Fi equipment

 

Wireless access points

 

Communication equipment

 

RF transmitters

 

Wireless devices

 

Commercial communication installations

 

Selected telecommunication environments

 

Always confirm that the frequency being investigated falls within the instrument's 50 MHz–10 GHz RF measurement range.

 

Magnetic Field vs Electric Field vs RF

 

The easiest way to understand the TM-290 is to consider the source you are investigating.

 

Electrical power equipment

 

You may be interested in the 50/60 Hz magnetic and electric fields.

 

Wireless or communication equipment

 

You may be more interested in the RF field.

 

Unknown EMF source

 

You may need to investigate more than one field type before understanding where the reading is coming from.

 

This is where a multi-field instrument can be particularly convenient.

 

Why a 3-in-1 EMF Meter Can Be Useful

 

Suppose you enter an equipment room containing:

 

Electrical distribution panels

 

UPS equipment

 

Power cables

 

Network equipment

 

Wireless communication devices

 

There may be several potential electromagnetic sources in the same environment.

 

Using an instrument that measures only magnetic fields will not provide RF measurement.

 

Similarly, an RF-only meter does not replace a low-frequency magnetic-field meter.

 

The TENMARS TM-290 combines all three measurement functions in one handheld meter:

 

Magnetic Field + Electric Field + RF

 

This makes it useful for preliminary investigation and general field checking where multiple EMF sources may be present.

 

Example: Checking an Office

 

In an office, a user may want to investigate several locations.

 

For example:

 

Near electrical equipment

Check low-frequency magnetic and electric fields.

 

Near an electrical distribution panel

Check 50/60 Hz magnetic-field levels at different distances.

 

Near Wi-Fi equipment

Use the RF measurement function where the source frequency falls within the meter's specified RF range.

 

At a workstation

Compare readings at different locations rather than relying on only one measurement point.

 

This approach provides more useful information than taking a single reading without identifying the type of field being measured.

 

Example: Checking a Factory

 

Factories can contain many electrical and electronic systems.

 

Possible investigation points include:

 

Motors

 

Control panels

 

Distribution boards

 

Electrical rooms

 

Production machinery

 

Wireless communication equipment

 

The TM-290 allows technicians to switch between the appropriate measurement functions according to the source being investigated.

 

Example: Data Centre EMF Investigation

 

A data centre can contain both power infrastructure and communication equipment.

 

Potential investigation areas may include:

 

Electrical distribution areas

 

UPS systems

 

Power equipment

 

Server areas

 

Network infrastructure

 

Wireless equipment

 

The TM-290 can therefore be used as a portable instrument for general EMF investigation across different types of sources.

 

It is important, however, to understand what parameter is being measured rather than treating every displayed value as the same type of EMF reading.

 

Why Measurement Units Matter

 

Different EMF parameters use different units.

 

For example:

 

Magnetic field: mG or µT

Electric field: V/m

RF field: may be displayed in units such as µW/m², mW/m² or V/m

 

These units represent different physical quantities.

 

Therefore, a value shown in µT should not be directly compared numerically with a value shown in V/m or mW/m².

 

Understanding the measurement mode and unit is essential when recording or interpreting results.

 

TENMARS TM-290 for EMF Investigation in Malaysia

 

The TENMARS TM-290 is especially useful when users need more than a basic single-function EMF meter.

 

Its three measurement capabilities cover:

 

50/60 Hz Magnetic Field

50/60 Hz Electric Field

50 MHz–10 GHz RF Field

 

This combination makes the instrument suitable for general EMF investigation in factories, offices, commercial buildings, electrical facilities, data centres and other environments where different electromagnetic sources may be present.

 

For TENMARS TM-290 availability, quotation or technical enquiries in Malaysia, contact:

 

MTM Precision Sdn Bhd

Puchong Showroom & Service Centre

 

Tel: 03-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com

Website: www.mtmpre.com.my

 

Serving customers throughout Malaysia, including Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.


 

20 Sep 2026