How to Perform a Basic Workplace EMF Survey with TENMARS TM-290 Malaysia
How to Perform a Basic Workplace EMF Survey with TENMARS TM-290 Malaysia
A workplace can contain many different electromagnetic field sources.
Electrical panels, motors, transformers, UPS systems, computers, Wi-Fi access points and communication equipment may all contribute to the electromagnetic environment.
However, these sources do not necessarily produce the same type of field.
A basic workplace EMF survey should therefore begin by identifying the equipment and selecting the appropriate measurement mode.
The TENMARS TM-290 Multi-Field EMF Meter combines:
50/60 Hz 3-axis magnetic-field measurement
50/60 Hz electric-field measurement
50 MHz to 10 GHz RF field measurement
This makes it suitable for general EMF investigation across workplaces containing both electrical and wireless equipment.
Step 1: Define the Purpose of the Survey
Before switching on the meter, decide what you are trying to investigate.
For example:
Are you checking an electrical panel?
Are you investigating a transformer or motor?
Are you checking a normal employee working position?
Are you investigating RF fields around wireless equipment?
Are you comparing several areas within a building?
A clear objective helps determine which measurement mode and locations should be used.
Step 2: Identify Possible EMF Sources
Walk through the workplace and identify relevant equipment.
Possible low-frequency electrical sources include:
Electrical panels
Distribution boards
Transformers
Motors
Pumps
Compressors
Generators
UPS systems
Power supplies
Electrical cabling
Industrial machinery
Possible RF sources may include:
Wi-Fi access points
Wireless communication equipment
RF transmitting equipment
Other compatible wireless devices
This initial equipment list can be used to create the measurement route.
Step 3: Select the Correct Measurement Mode
The TENMARS TM-290 provides three major measurement functions.
Magnetic Field
Frequency:
50/60 Hz
Ranges:
or:
2 / 20 / 200 uT
The meter provides X, Y and Z three-axis measurement.
Electric Field
Frequency:
50/60 Hz
Range:
50 V/m to 2000 V/m
RF Field
Frequency:
50 MHz to 10 GHz
Measurement range:
0.2 uW/m2 to 554.6 mW/m2
Choose the measurement mode according to the source being investigated.
Step 4: Establish Measurement Points
Avoid walking randomly around the workplace looking only for the highest displayed number.
Instead, establish defined measurement locations.
For an electrical panel, for example:
Point A: Near the panel
Point B: 0.5 m away
Point C: 1 m away
Point D: Normal technician working position
For an office:
Point A: Electrical distribution area
Point B: Normal workstation
Point C: Near wireless access point
Point D: Meeting room
Point E: General office reference location
Defined measurement points make the survey easier to repeat.
Step 5: Record the Distance
Distance is important when documenting EMF measurements.
A reading taken directly beside a machine cannot automatically be compared with one taken several metres away.
Record the approximate distance between the meter and the source whenever possible.
For example:
Location: Panel A
Distance: 1 m
Measurement: Magnetic Field
Reading: XX uT
This provides useful context.
Step 6: Record the Equipment Condition
Equipment operating conditions may affect measurements.
For example:
Motor running or stopped
Pump operating or idle
UPS under load
Production machine operating
Electrical system under normal load
If measurements will be repeated later, similar operating conditions can improve comparison.
Step 7: Check Normal Working Positions
Do not measure only directly beside equipment.
A workplace survey may also include positions where employees or technicians normally spend time.
Examples include:
Operator station
Maintenance position
Office workstation
Control room desk
Server aisle
Electrical panel working position
A measurement taken close to a source answers a different question from one taken at the normal working position.
Both may provide useful information.
Step 8: Use 3-Axis Measurement for Magnetic Fields
The TM-290 provides X, Y and Z three-axis magnetic-field measurement.
This is useful because magnetic fields have direction.
A single-axis instrument can produce different readings depending on its orientation relative to the field.
Three-axis measurement allows the TM-290 to measure field components along multiple axes and provide an aggregated result.
This can make general workplace surveys more convenient.
Step 9: Treat RF Separately
RF measurements should be treated separately from 50/60 Hz magnetic and electric-field measurements.
For RF investigation, first confirm that the source frequency falls within the TM-290's:
50 MHz to 10 GHz
frequency range.
RF readings may vary according to:
Distance
Transmitter activity
Antenna characteristics
Building layout
Walls and obstacles
Reflections
Other RF sources
Take measurements at defined positions rather than relying on one reading.
Step 10: Record the Correct Unit
Do not record only a number.
For example:
Reading = 15
does not provide enough information.
Instead, record:
15 mG
15 uT
15 V/m
or:
15 uW/m2
depending on the measurement mode.
Magnetic, electric and RF measurements should not be directly compared as though they represent the same physical quantity.
Example: Factory EMF Survey
A simple factory survey route could include:
1. Main Electrical Panel
Check 50/60 Hz magnetic and electric fields.
2. Transformer Area
Check magnetic-field readings at selected distances.
3. Motor and Pump Area
Record magnetic-field measurements at defined locations.
4. Operator Position
Take measurements where personnel normally work.
5. Wireless Equipment
Use RF measurement where the source frequency falls within the TM-290 specification.
This provides a structured survey rather than a collection of unrelated readings.
Example: Office EMF Survey
An office survey might include:
Electrical Distribution Area
Check low-frequency fields.
Workstations
Record measurements at normal working positions.
Wi-Fi Access Points
Check RF field strength at defined locations.
Meeting Rooms
Compare RF measurements with other areas.
Reference Location
Use a consistent location for comparison.
Example: Data Centre Workplace Survey
A data centre survey may include:
UPS area
Power distribution area
Server aisles
Network equipment area
Wireless equipment
Technician working positions
The TM-290's multi-field capability is useful because both electrical and RF sources may exist within the same facility.
A Simple EMF Survey Record
A useful record format is:
Location: Electrical Panel A
Equipment: Main Distribution Panel
Measurement Mode: Magnetic Field
Reading: XX uT
Distance: 1 m
Equipment Condition: Normal Operation
Measurement Position: Front of Panel
For RF:
Location: Office Area A
Equipment: Wireless Access Point
Measurement Mode: RF Field
Reading: XX uW/m2
Distance: 2 m
Equipment Condition: Operating
This makes future comparisons easier.
Basic Survey vs Formal Compliance Assessment
A basic EMF survey and a formal occupational exposure assessment are not necessarily the same thing.
Formal compliance work may require:
Specific measurement procedures
Appropriate calibrated instruments
Defined measurement locations
Exposure duration assessment
Measurement uncertainty consideration
Applicable occupational exposure limits
Formal documentation
If the measurement is required for regulatory or occupational compliance, follow the relevant standard and measurement procedure.
TENMARS TM-290 for Workplace EMF Survey Malaysia
The TENMARS TM-290 provides:
3-Axis Magnetic Field: 50/60 Hz
Electric Field: 50/60 Hz
RF Field: 50 MHz to 10 GHz
This combination makes it useful for general workplace EMF investigation in factories, offices, electrical rooms, commercial buildings, data centres and other locations containing different electromagnetic sources.
For TENMARS TM-290 quotation, stock availability or technical enquiries in Malaysia, contact:
MTM Precision Sdn Bhd
Puchong Showroom & Service Centre
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Serving customers throughout Malaysia, including Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.
20 Sep 2026