A PM2.5 monitor can show the concentration of fine airborne particles inside a building, but the result depends heavily on where the instrument is placed.

 

A reading taken directly beside an air purifier, air-conditioning outlet, open window or kitchen may not represent the air that occupants normally breathe.

 

For meaningful indoor air-quality monitoring in Malaysia, the instrument should be positioned according to the measurement objective and used at several representative locations.

 

Why Measurement Location Matters

 

PM2.5 is not always distributed evenly throughout a building.

 

Particle concentrations can vary because of:

 

Outdoor haze entering through doors and windows

 

Air-conditioning and ventilation patterns

 

Air-purifier position

 

Cooking or smoking

 

Cleaning and renovation activities

 

Occupant movement

 

Room size and layout

 

Differences in building leakage

 

A single reading from one convenient corner may therefore give an incomplete picture of indoor air quality.

 

General Placement Guidelines

 

For a representative measurement:

 

Position the monitor near the normal breathing zone

 

Keep it away from direct sunlight

 

Avoid placing it directly on the floor

 

Do not block the sensor inlet

 

Keep it away from walls and enclosed corners

 

Avoid direct airflow from fans and air-conditioning outlets

 

Allow the reading to stabilise

 

Record the measurement location and time

 

For routine indoor checks, table or desk height is usually more representative than floor or ceiling level.

 

Best Places to Measure PM2.5 Inside a Home

 

Living Room

 

The living room is often the main occupied area and is a useful starting point.

 

Place the monitor:

 

Near the centre of the occupied area

 

At table height

 

Away from an air-conditioner or air purifier outlet

 

Away from direct cooking smoke

 

This reading provides a practical indication of the air normally experienced by family members.

 

Bedroom

 

Measure inside the bedroom because doors may remain closed for long periods and occupants spend several hours there while sleeping.

 

A suitable position is:

 

Near the bed but not directly beside the occupant’s face

 

Away from an open window

 

Away from the air-conditioner outlet

 

Away from an air purifier’s clean-air discharge

 

Compare the reading before sleeping, after several hours and in the morning.

 

Near Windows and External Doors

 

During haze, outdoor particles may enter through openings and gaps.

 

Take a comparison reading near:

 

Frequently opened doors

 

Windows facing roads

 

Balcony doors

 

Poorly sealed window frames

 

This location should not be used as the only reading for the entire home. It is an investigation point for identifying particle entry.

 

Kitchen and Dining Area

 

Cooking can generate high concentrations of fine particles, especially during frying, grilling or high-temperature cooking.

 

Measure:

 

Away from direct steam

 

At the dining or occupied area

 

Before, during and after cooking

 

With and without the exhaust system operating

 

Do not place the monitor directly above a stove because heat, oil mist and steam may affect the sensor or contaminate it.

 

Best Places to Measure PM2.5 Inside a School

 

Classroom Breathing Zone

 

Place the monitor within the occupied section of the classroom, approximately at seated breathing height.

 

Avoid positioning it:

 

Directly beside the teacher’s whiteboard

 

Near an open door

 

Directly under an air-conditioning outlet

 

Beside a window

 

Inside a cabinet or bookshelf

 

The objective is to measure the air experienced by students, not the cleanest or most polluted isolated point.

 

Near the Classroom Entrance

 

Doors may be opened frequently between lessons, allowing outdoor particles to enter.

 

A second measurement near the entrance can help determine whether traffic through the doorway is affecting the classroom.

 

Near Windows Facing Roads or Outdoor Activity

 

Schools near roads, construction work or open burning may experience local particle sources in addition to regional haze.

 

Compare readings near the window and in the centre of the classroom.

 

School Hall and Assembly Area

 

Large halls may have uneven air distribution. Measure at several locations rather than relying on one instrument placed near the entrance.

 

Important points include:

 

Main occupied area

 

Stage or activity area

 

Entrance

 

Areas near ventilation openings

 

Library and Computer Room

 

Enclosed rooms may have different ventilation and filtration conditions from regular classrooms.

 

These rooms should be checked separately, particularly when they remain closed and air-conditioned for long periods.

 

Best Places to Measure PM2.5 Inside an Office

 

Employee Work Area

 

Position the monitor within the occupied workspace at desk height.

 

Avoid placing it directly beside:

 

A desktop fan

 

An air purifier

 

A printer

 

An air-conditioning outlet

 

An open window

 

For an open-plan office, measurements should be taken in more than one zone.

 

Meeting Room

 

Meeting rooms may experience rapid changes when several people occupy a relatively small enclosed space.

 

PM2.5 should be considered together with ventilation-related parameters such as carbon dioxide, temperature and relative humidity.

 

Measure:

 

Before occupants enter

 

During the meeting

 

After the room is vacated

 

Reception and Main Entrance

 

Frequently opened doors can allow haze and road pollution to enter.

 

A reception-area measurement can help identify whether the entrance is a major particle pathway.

 

Compare it with a reading further inside the office.

 

Printing or Photocopy Area

 

Printers and office activities may contribute to local airborne particles and VOCs.

 

The monitor should be positioned near the occupied area rather than directly against the equipment exhaust.

 

Pantry

 

Cooking, toasting and heating food can temporarily increase particle readings.

 

If the office monitor frequently records sudden peaks, compare the timing with pantry activity.

 

Where Not to Place a PM2.5 Monitor

 

Avoid using the following locations for a representative room reading:

 

Directly in front of an air purifier

 

Under an air-conditioning outlet

 

Beside a fan

 

Directly beside an open window

 

Above a cooking stove

 

Next to a humidifier

 

Inside a cupboard

 

On the floor

 

Against a wall

 

In direct sunlight

 

Beside aerosol sprays or cleaning chemicals

 

These positions may produce unusually high or low readings that do not represent normal occupant exposure.

 

How Many Measurement Points Are Needed?

 

The required number depends on room size, layout and the purpose of the assessment.

 

For a small room, begin with:

 

One representative occupied location

 

One suspected particle-entry point

 

One location used to evaluate an air purifier or filtration system

 

For a large office, school hall or factory area, divide the space into zones and compare readings.

 

More measurement points may be needed when:

 

The room has several entrances

 

Airflow is uneven

 

Multiple air-conditioning units are operating

 

Occupants report problems only in certain areas

 

Outdoor pollution sources are located on one side of the building

 

How Long Should Each Measurement Take?

 

Allow the monitor to stabilise before recording the result.

 

For comparison work, use a consistent procedure at every location:

 

Same instrument

 

Similar stabilisation period

 

Same measurement height

 

Similar operating conditions

 

Recorded time and location

 

Trend measurements over several hours or days are more useful than isolated readings when evaluating haze entry, filtration or building operation.

 

Testing Air-Purifier Performance

 

To evaluate an air purifier:

 

Record the starting PM2.5 concentration.

 

Close doors and windows where practical.

 

Switch on the purifier.

 

Place the monitor in the occupied area.

 

Avoid placing it directly in the purifier’s outlet airflow.

 

Record the reading at consistent intervals.

 

Repeat the test in another part of the room.

 

A low reading directly beside the purifier does not prove that the whole room has reached the same condition.

 

Information to Record

 

Each measurement record should include:

 

Date and time

 

Room and exact location

 

PM2.5 reading

 

Outdoor API condition

 

Door and window status

 

Air-conditioning status

 

Air-purifier setting

 

Occupancy

 

Cooking, cleaning or renovation activity

 

Any unusual smell, smoke or visible dust

 

This information makes it easier to explain differences and recommend corrective action.

 

Selecting a PM2.5 Monitor

 

Consider the following before choosing an instrument:

 

PM2.5 measurement capability

 

PM10 measurement requirement

 

Real-time display

 

Data logging

 

Alarm function

 

Battery operating time

 

Portability

 

Additional CO2, HCHO or TVOC measurements

 

Temperature and humidity display

 

Intended household, commercial or professional use

 

Different applications require different combinations of parameters.

 

PM2.5 Monitors Available from MTM Precision

 

MTM Precision supplies Temtop air-quality instruments for haze checks and indoor monitoring in Malaysia.

 

Relevant models include:

 

Temtop P600

 

Temtop M10i

 

Temtop M10+

 

Temtop M100

 

Temtop S1 up

 

Temtop C1+

 

Temtop M2000 2nd Generation

 

Temtop LKC-1000S 2nd Generation

 

Available functions vary by model. Confirm whether you require PM2.5 only or additional measurements such as PM10, CO2, HCHO, TVOC, temperature and relative humidity.

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd. (744811-A)

 

Tel: 03-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my

Website: www.mtmpre.com.my

 

Visit our Puchong Showroom & Service Centre for product selection, demonstration and technical support.

 

Operating hours: Monday to Friday, 9:00 AM–6:00 PM.


 

20 Sep 2026