Best Places to Measure PM2.5 Inside a Home, School or Office Malaysia
Best Places to Measure PM2.5 Inside a Home, School or Office Malaysia
Content
A PM2.5 monitor can show the concentration of fine airborne particles inside a building, but the result depends heavily on where the instrument is placed.
A reading taken directly beside an air purifier, air-conditioning outlet, open window or kitchen may not represent the air that occupants normally breathe.
For meaningful indoor air-quality monitoring in Malaysia, the instrument should be positioned according to the measurement objective and used at several representative locations.
Why Measurement Location Matters
PM2.5 is not always distributed evenly throughout a building.
Particle concentrations can vary because of:
Outdoor haze entering through doors and windows
Air-conditioning and ventilation patterns
Air-purifier position
Cooking or smoking
Cleaning and renovation activities
Occupant movement
Room size and layout
Differences in building leakage
A single reading from one convenient corner may therefore give an incomplete picture of indoor air quality.
General Placement Guidelines
For a representative measurement:
Position the monitor near the normal breathing zone
Keep it away from direct sunlight
Avoid placing it directly on the floor
Do not block the sensor inlet
Keep it away from walls and enclosed corners
Avoid direct airflow from fans and air-conditioning outlets
Allow the reading to stabilise
Record the measurement location and time
For routine indoor checks, table or desk height is usually more representative than floor or ceiling level.
Best Places to Measure PM2.5 Inside a Home
Living Room
The living room is often the main occupied area and is a useful starting point.
Place the monitor:
Near the centre of the occupied area
At table height
Away from an air-conditioner or air purifier outlet
Away from direct cooking smoke
This reading provides a practical indication of the air normally experienced by family members.
Bedroom
Measure inside the bedroom because doors may remain closed for long periods and occupants spend several hours there while sleeping.
A suitable position is:
Near the bed but not directly beside the occupant’s face
Away from an open window
Away from the air-conditioner outlet
Away from an air purifier’s clean-air discharge
Compare the reading before sleeping, after several hours and in the morning.
Near Windows and External Doors
During haze, outdoor particles may enter through openings and gaps.
Take a comparison reading near:
Frequently opened doors
Windows facing roads
Balcony doors
Poorly sealed window frames
This location should not be used as the only reading for the entire home. It is an investigation point for identifying particle entry.
Kitchen and Dining Area
Cooking can generate high concentrations of fine particles, especially during frying, grilling or high-temperature cooking.
Measure:
Away from direct steam
At the dining or occupied area
Before, during and after cooking
With and without the exhaust system operating
Do not place the monitor directly above a stove because heat, oil mist and steam may affect the sensor or contaminate it.
Best Places to Measure PM2.5 Inside a School
Classroom Breathing Zone
Place the monitor within the occupied section of the classroom, approximately at seated breathing height.
Avoid positioning it:
Directly beside the teacher’s whiteboard
Near an open door
Directly under an air-conditioning outlet
Beside a window
Inside a cabinet or bookshelf
The objective is to measure the air experienced by students, not the cleanest or most polluted isolated point.
Near the Classroom Entrance
Doors may be opened frequently between lessons, allowing outdoor particles to enter.
A second measurement near the entrance can help determine whether traffic through the doorway is affecting the classroom.
Near Windows Facing Roads or Outdoor Activity
Schools near roads, construction work or open burning may experience local particle sources in addition to regional haze.
Compare readings near the window and in the centre of the classroom.
School Hall and Assembly Area
Large halls may have uneven air distribution. Measure at several locations rather than relying on one instrument placed near the entrance.
Important points include:
Main occupied area
Stage or activity area
Entrance
Areas near ventilation openings
Library and Computer Room
Enclosed rooms may have different ventilation and filtration conditions from regular classrooms.
These rooms should be checked separately, particularly when they remain closed and air-conditioned for long periods.
Best Places to Measure PM2.5 Inside an Office
Employee Work Area
Position the monitor within the occupied workspace at desk height.
Avoid placing it directly beside:
A desktop fan
An air purifier
A printer
An air-conditioning outlet
An open window
For an open-plan office, measurements should be taken in more than one zone.
Meeting Room
Meeting rooms may experience rapid changes when several people occupy a relatively small enclosed space.
PM2.5 should be considered together with ventilation-related parameters such as carbon dioxide, temperature and relative humidity.
Measure:
Before occupants enter
During the meeting
After the room is vacated
Reception and Main Entrance
Frequently opened doors can allow haze and road pollution to enter.
A reception-area measurement can help identify whether the entrance is a major particle pathway.
Compare it with a reading further inside the office.
Printing or Photocopy Area
Printers and office activities may contribute to local airborne particles and VOCs.
The monitor should be positioned near the occupied area rather than directly against the equipment exhaust.
Pantry
Cooking, toasting and heating food can temporarily increase particle readings.
If the office monitor frequently records sudden peaks, compare the timing with pantry activity.
Where Not to Place a PM2.5 Monitor
Avoid using the following locations for a representative room reading:
Directly in front of an air purifier
Under an air-conditioning outlet
Beside a fan
Directly beside an open window
Above a cooking stove
Next to a humidifier
Inside a cupboard
On the floor
Against a wall
In direct sunlight
Beside aerosol sprays or cleaning chemicals
These positions may produce unusually high or low readings that do not represent normal occupant exposure.
How Many Measurement Points Are Needed?
The required number depends on room size, layout and the purpose of the assessment.
For a small room, begin with:
One representative occupied location
One suspected particle-entry point
One location used to evaluate an air purifier or filtration system
For a large office, school hall or factory area, divide the space into zones and compare readings.
More measurement points may be needed when:
The room has several entrances
Airflow is uneven
Multiple air-conditioning units are operating
Occupants report problems only in certain areas
Outdoor pollution sources are located on one side of the building
How Long Should Each Measurement Take?
Allow the monitor to stabilise before recording the result.
For comparison work, use a consistent procedure at every location:
Same instrument
Similar stabilisation period
Same measurement height
Similar operating conditions
Recorded time and location
Trend measurements over several hours or days are more useful than isolated readings when evaluating haze entry, filtration or building operation.
Testing Air-Purifier Performance
To evaluate an air purifier:
Record the starting PM2.5 concentration.
Close doors and windows where practical.
Switch on the purifier.
Place the monitor in the occupied area.
Avoid placing it directly in the purifier’s outlet airflow.
Record the reading at consistent intervals.
Repeat the test in another part of the room.
A low reading directly beside the purifier does not prove that the whole room has reached the same condition.
Information to Record
Each measurement record should include:
Date and time
Room and exact location
PM2.5 reading
Outdoor API condition
Door and window status
Air-conditioning status
Air-purifier setting
Occupancy
Cooking, cleaning or renovation activity
Any unusual smell, smoke or visible dust
This information makes it easier to explain differences and recommend corrective action.
Selecting a PM2.5 Monitor
Consider the following before choosing an instrument:
PM2.5 measurement capability
PM10 measurement requirement
Real-time display
Data logging
Alarm function
Battery operating time
Portability
Additional CO2, HCHO or TVOC measurements
Temperature and humidity display
Intended household, commercial or professional use
Different applications require different combinations of parameters.
PM2.5 Monitors Available from MTM Precision
MTM Precision supplies Temtop air-quality instruments for haze checks and indoor monitoring in Malaysia.
Relevant models include:
Temtop P600
Temtop M10i
Temtop M10+
Temtop M100
Temtop S1 up
Temtop C1+
Temtop M2000 2nd Generation
Temtop LKC-1000S 2nd Generation
Available functions vary by model. Confirm whether you require PM2.5 only or additional measurements such as PM10, CO2, HCHO, TVOC, temperature and relative humidity.
Contact MTM Precision
MTM Precision Sdn. Bhd. (744811-A)
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my
Website: www.mtmpre.com.my
Visit our Puchong Showroom & Service Centre for product selection, demonstration and technical support.
Operating hours: Monday to Friday, 9:00 AM–6:00 PM.
20 Sep 2026