Biological nitrogen removal systems depend on microorganisms to convert ammonia into nitrogen gas through several biological processes.

 

The treatment system may appear to be operating normally while ammonia, nitrite or nitrate levels are already moving outside the desired range. For this reason, checking only pH or dissolved oxygen is not enough.

 

Wastewater treatment plants in Malaysia should monitor a combination of process, water-quality and operating parameters to understand what is happening inside the system.

 

How Biological Nitrogen Removal Works

 

A conventional biological nitrogen removal process normally includes two main stages.

 

Nitrification

 

Under aerobic conditions, microorganisms convert:

 

Ammonia → Nitrite → Nitrate

 

This process requires sufficient dissolved oxygen and is sensitive to pH, temperature, alkalinity and toxic substances.

 

Denitrification

 

Under low-oxygen or anoxic conditions, other microorganisms convert nitrate into nitrogen gas.

 

This process requires:

 

Low dissolved oxygen

 

An available carbon source

 

Suitable pH and temperature

 

Adequate contact time

 

Stable mixing

 

More advanced processes, including partial nitritation and Anammox, use different biological pathways. However, they still require careful monitoring of nitrogen species, dissolved oxygen, temperature and process stability.

 

1. Dissolved Oxygen

 

Dissolved oxygen, or DO, is one of the most important control parameters.

 

In the aerobic zone, insufficient DO can slow nitrification and cause ammonia to remain in the treated water.

 

Excessive aeration can:

 

Increase electricity consumption

 

Carry oxygen into an anoxic zone

 

Reduce denitrification performance

 

Make process control less efficient

 

The correct DO target depends on the treatment design, loading, temperature and biological process. Operators should not assume that one universal setting is suitable for every plant.

 

Practical Measurement Points

 

DO should be checked:

 

Near the beginning of the aeration tank

 

In the middle of the aerobic zone

 

Near the end of the aeration tank

 

Inside the anoxic zone

 

During high- and low-loading periods

 

One measurement at the tank surface may not represent conditions throughout the basin.

 

2. pH

 

Nitrification consumes alkalinity and can cause pH to fall.

 

When pH becomes unsuitable, biological activity may slow even when aeration appears normal.

 

pH monitoring helps operators identify:

 

Loss of alkalinity

 

Acidic or alkaline influent

 

Chemical dosing problems

 

Process imbalance

 

Conditions that may inhibit microorganisms

 

A pH reading should always be interpreted together with alkalinity, temperature and nitrogen results.

 

3. Temperature

 

Biological reaction rates change with temperature.

 

Lower temperatures generally slow microbial activity, while excessive temperature or sudden temperature changes may disturb the biological population.

 

In Malaysia, wastewater may remain relatively warm, but temperature still varies because of:

 

Industrial discharge

 

Weather and rainfall

 

Tank exposure

 

Production schedules

 

Cooling-water discharge

 

Changes between day and night

 

Temperature should be recorded together with DO because oxygen solubility and biological oxygen demand are temperature-dependent.

 

4. Ammonia or Ammonium

 

Ammonia measurement shows whether nitrogen entering the system is being successfully converted.

 

Rising ammonia at the outlet of the aerobic zone may indicate:

 

Insufficient dissolved oxygen

 

Excessive nitrogen loading

 

Inadequate sludge age

 

Unfavourable pH

 

Low alkalinity

 

Temperature changes

 

Toxic or inhibitory influent

 

Loss of active nitrifying microorganisms

 

Influent and effluent ammonia results should be compared. A single final-effluent result cannot show where the process began to fail.

 

5. Nitrite

 

Nitrite is an intermediate product between ammonia and nitrate.

 

An increase in nitrite may indicate that ammonia oxidation and nitrite oxidation are no longer balanced.

 

Possible causes include:

 

Changes in dissolved oxygen

 

Sudden loading variations

 

pH or temperature disturbance

 

Inhibition of nitrite-oxidising bacteria

 

An unstable partial-nitritation process

 

Nitrite is particularly important in systems designed to maintain partial nitritation or support Anammox treatment.

 

6. Nitrate

 

Nitrate helps show whether nitrification has occurred and whether denitrification is removing the oxidised nitrogen.

 

High nitrate after the anoxic stage may be associated with:

 

Insufficient carbon source

 

Excess dissolved oxygen

 

Poor internal recirculation

 

Inadequate mixing

 

Short retention time

 

Low biological activity

 

Nitrate should be interpreted together with ammonia and nitrite. Measuring nitrate alone does not show the complete nitrogen-conversion pathway.

 

7. Oxidation-Reduction Potential

 

Oxidation-reduction potential, or ORP, can provide useful information about the oxidation or reduction conditions inside a biological treatment zone.

 

ORP trending may help operators observe transitions between:

 

Aerobic conditions

 

Anoxic conditions

 

Anaerobic conditions

 

It can support process control, but it should not be treated as a direct replacement for DO, ammonia, nitrite or nitrate testing.

 

Electrode cleanliness, installation location and wastewater composition can affect ORP readings.

 

8. Alkalinity

 

Nitrification consumes alkalinity. If the available alkalinity becomes too low, the pH can fall and nitrification performance may deteriorate.

 

Alkalinity measurement is useful when:

 

pH is gradually decreasing

 

Ammonia removal becomes unstable

 

Chemical dosing is used

 

Influent composition changes

 

Industrial wastewater enters the system

 

pH shows the current acid-base condition, while alkalinity indicates the water’s capacity to resist further pH change. They are related but not interchangeable.

 

9. Mixed Liquor Suspended Solids

 

Mixed liquor suspended solids, commonly called MLSS, represents the suspended biomass and solids inside an activated-sludge process.

 

MLSS monitoring helps evaluate whether the system has:

 

Too little biomass

 

Excessive solids accumulation

 

Sludge wasting problems

 

Solids loss

 

Changes in treatment loading

 

A high MLSS result does not automatically mean that the biological population is healthy. The solids may include inactive biomass or non-biological material.

 

10. Sludge Settleability

 

Sludge-volume and settling tests help identify whether the biomass can be separated from treated water.

 

Poor settling may cause:

 

High suspended solids in the final effluent

 

Biomass loss

 

Reduced sludge age

 

Deteriorating nitrification

 

Clarifier problems

 

Settling results should be assessed together with MLSS, sludge age, microscopic observations and clarifier operation.

 

11. Flow and Hydraulic Loading

 

Flow measurement provides the context needed to interpret all concentration results.

 

The same ammonia concentration can represent very different total nitrogen loads at different flow rates.

 

Flow changes may be caused by:

 

Production schedules

 

Heavy rainfall

 

Infiltration

 

Cleaning operations

 

Batch discharge

 

Pump or valve problems

 

Where possible, treatment performance should be evaluated using both concentration and mass loading.

 

12. Carbon Source and Organic Loading

 

Denitrification requires an appropriate electron donor, usually an available biodegradable carbon source.

 

When carbon is insufficient, nitrate may remain high even when the anoxic tank appears to be operating normally.

 

Useful supporting parameters may include:

 

COD

 

BOD

 

TOC

 

Carbon dosing rate

 

Influent composition

 

Adding too much external carbon can increase cost and create new effluent-quality problems. Dosing should therefore be supported by process data.

 

Recommended Monitoring Combination

 

A practical biological nitrogen-removal monitoring programme should include:

 

Frequent Field or Online Measurements

 

Dissolved oxygen

 

pH

 

Temperature

 

ORP

 

Flow

 

Routine Process Tests

 

Ammonia

 

Nitrite

 

Nitrate

 

Alkalinity

 

MLSS

 

Suspended solids

 

Sludge settleability

 

Supporting Operational Records

 

Aeration setting

 

Internal recirculation rate

 

Return and waste sludge rates

 

Chemical or carbon dosing

 

Tank retention time

 

Production and influent changes

 

The most useful information comes from comparing these measurements as a trend rather than judging the process from one isolated reading.

 

Portable Meter or Online Sensor?

 

Portable instruments are useful for:

 

Checking several locations

 

Verifying an online sensor

 

Investigating process problems

 

Conducting maintenance checks

 

Comparing different tanks

 

Online sensors are more suitable for:

 

Continuous monitoring

 

Automatic alarms

 

Process control

 

Aeration adjustment

 

Long-term trending

 

Many facilities require both. An online instrument identifies changes continuously, while a portable meter helps confirm whether the change is genuine and locate the affected area.

 

Common Troubleshooting Examples

 

High Effluent Ammonia

 

Check:

 

DO distribution

 

pH and alkalinity

 

Temperature

 

Influent ammonia loading

 

Sludge age

 

Toxic influent

 

Biomass loss

 

High Nitrite

 

Check:

 

DO stability

 

pH and temperature

 

Sudden load changes

 

Inhibition

 

Balance between ammonia- and nitrite-oxidising organisms

 

High Nitrate After the Anoxic Zone

 

Check:

 

Carbon availability

 

Anoxic-zone DO

 

Mixing

 

Internal recirculation

 

Retention time

 

Nitrate loading

 

Unstable Readings

 

Check:

 

Probe cleanliness

 

Calibration status

 

Temperature compensation

 

Sample location

 

Air bubbles around the sensor

 

Cable and connector condition

 

Comparison against a second instrument or laboratory result

 

Water-Quality Instruments from MTM Precision

 

MTM Precision supplies portable and laboratory water-quality instruments for wastewater treatment, process troubleshooting and routine field measurements in Malaysia.

 

Relevant categories include:

 

Dissolved-oxygen meters

 

Portable and benchtop pH meters

 

ORP meters

 

EC and TDS meters

 

Turbidity meters

 

Suspended-solids meters

 

Temperature meters

 

Multi-parameter water-quality instruments

 

Calibration buffers and standard solutions

 

Available instruments include the QiWei 70A dissolved-oxygen meter, QiWei PH220W portable pH meter, PHS-25 benchtop pH meter, WGZ-1B turbidity meter and PAL-401 suspended-solids meter.

 

Instrument selection should be based on the required parameter, measurement range, sample condition, field environment and calibration requirements.

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd. (744811-A)

 

Tel: 03-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my

Website: www.mtmpre.com.my

 

Visit our Puchong Showroom & Service Centre for water-quality instrument selection, demonstration and technical support.

 

Operating hours: Monday to Friday, 9:00 AM–6:00 PM.


 

20 Sep 2026