How to Measure Corroded Metal Thickness Malaysia
How to Measure Corroded Metal Thickness Malaysia
How can you determine how much metal remains after years of corrosion?
Looking at rust can tell you that corrosion exists, but it cannot reliably tell you the remaining material thickness.
For suitable metal components, an ultrasonic thickness gauge such as the UNI-T UT345A can be used to measure thickness from one accessible side without cutting the component.
This makes ultrasonic thickness measurement useful for pipes, tanks, steel plates, industrial equipment and maintenance applications in Malaysia.
Why Visual Inspection Is Not Enough
Consider two steel pipes.
The first has obvious external rust.
The second looks relatively clean externally.
Which pipe has the thinner remaining wall?
You cannot reliably answer that question based on appearance alone.
External appearance and remaining wall thickness are different measurements.
Ultrasonic thickness testing provides quantitative thickness data at selected locations.
What Does an Ultrasonic Thickness Gauge Measure?
An ultrasonic thickness gauge measures the distance between the accessible test surface and the opposite material boundary under suitable conditions.
The probe sends an ultrasonic pulse into the material.
The pulse travels through the material, reflects from the back wall and returns to the probe.
The instrument calculates thickness using:
Ultrasonic travel time + Material sound velocity
This allows suitable components to be measured from one side.
UNI-T UT345A for Corroded Metal
The UNI-T UT345A Ultrasonic Thickness Gauge has a specified measurement range of approximately:
1.00–300.00 mm
with adjustable sound velocity of approximately:
1000–9999 m/s.
It can be considered for suitable thickness-measurement applications involving:
Metal pipes
Steel plates
Storage tanks
Fabricated components
Industrial equipment
Selected machinery components
Actual suitability depends on material, geometry, surface condition and inspection requirements.
Step 1: Identify the Material
Before measuring, determine what material you are testing.
Ultrasonic thickness calculation depends on sound velocity.
Using the wrong sound velocity can produce an incorrect thickness even if the number on the display appears stable.
Do not simply adjust the setting until the displayed value looks reasonable.
Step 2: Inspect the Corroded Surface
Look closely at the measurement area.
Check for:
Loose rust
Heavy scale
Pitting
Flaking coating
Dirt
Severe roughness
A heavily corroded surface can make probe contact difficult.
The condition of the surface should therefore be considered before accepting any reading.
Step 3: Prepare the Measurement Location
Loose corrosion products may need to be removed appropriately so that the probe can make suitable contact with the test surface.
The objective is to create a usable measurement surface without unnecessarily removing sound base material.
For critical inspections, follow the applicable surface-preparation and measurement procedure.
Step 4: Configure and Verify the UT345A
Set the instrument appropriately for the material.
Before relying on measurements, follow the manufacturer's recommended calibration or verification procedure.
This helps confirm that the instrument, probe and settings are functioning appropriately.
Step 5: Apply Ultrasonic Couplant
Suitable ultrasonic couplant is normally applied between the probe and metal surface.
This helps create an acoustic path:
Probe → Couplant → Metal → Back-Wall Echo → Probe
Without good coupling, the UT345A may show:
No reading
Unstable reading
Intermittent reading
Poor repeatability
Step 6: Take the Measurement
Place the probe correctly on the prepared measurement location.
Wait for the reading to stabilise.
Do not immediately record the first number that appears.
For example:
6.02 mm → 6.01 mm → 6.02 mm
is very different from:
6.0 mm → 4.3 mm → 7.1 mm → No Reading
A rapidly changing value should be investigated before it is recorded.
Step 7: Remove the Probe and Repeat
Repeatability is important.
For example:
Measurement 1: 5.82 mm
Measurement 2: 5.81 mm
Measurement 3: 5.83 mm
This provides more confidence than one isolated reading, assuming the instrument has been correctly configured and verified.
Step 8: Measure Around the Corroded Area
Do not measure only the centre of the visible rust.
Corrosion can be uneven.
For example:
Point A: 6.1 mm
Point B: 5.9 mm
Point C: 4.8 mm
Point D: 6.0 mm
Point C is noticeably lower.
Verify the result and measure surrounding locations according to the inspection procedure.
Why Multiple Measurement Points Matter
Imagine a large corroded steel plate.
One location may still be close to its original thickness while another area has experienced significant material loss.
A measurement grid can help organise readings.
Location1234AA1A2A3A4BB1B2B3B4CC1C2C3C4
The actual spacing and number of measurements should be selected according to the component and inspection objective.
Measuring Corroded Pipe Thickness
Pipes introduce additional challenges because the surface is curved.
When checking a corroded pipe:
Identify the material.
Select the measurement locations.
Check the surface.
Prepare the area appropriately.
Apply couplant.
Position the probe correctly.
Obtain a stable reading.
Repeat the measurement.
Check surrounding locations.
Record the point for future comparison.
Do not assume one measurement represents the entire circumference of the pipe.
Check Different Positions Around the Pipe
Where appropriate, measurements can be taken around the pipe circumference.
For example:
12 o'clock: 6.0 mm
3 o'clock: 5.8 mm
6 o'clock: 5.0 mm
9 o'clock: 5.9 mm
This example shows why checking only the top of the pipe could miss a thinner location.
Measurement locations should follow the applicable inspection plan.
Measuring Corroded Tanks
Storage tanks can also develop localised wall loss.
Instead of one random measurement, establish repeatable measurement points or grids.
This allows maintenance teams to compare measurements over time.
For example:
2026: 7.8 mm
2027: 7.5 mm
2028: 7.2 mm
Assuming comparable measurement procedures were used, the history indicates a change in measured thickness.
What About Deep Pitting?
Severe pitting can make ultrasonic thickness measurement more challenging.
A probe may not sit consistently on a heavily irregular surface.
If readings fluctuate significantly:
Check surface preparation
Check couplant
Reposition the probe
Repeat the measurement
Check nearby points
For critical or complex corrosion, more specialised NDT methods or qualified inspection personnel may be required.
Can You Measure Through Rust?
The answer depends on the condition of the surface.
Do not assume that an ultrasonic thickness gauge can simply measure accurately through any amount of rust or scale.
Loose corrosion products and severe roughness can interfere with probe coupling.
Appropriate surface preparation is often important for reliable measurement.
Can You Measure Through Paint?
Paint and other coatings require consideration.
Depending on the coating, instrument and measurement technique, the coating may influence the result.
Do not automatically assume:
Displayed reading = remaining base-metal thickness
when measuring through an unknown coating.
For important measurements, follow the manufacturer's instructions and applicable inspection procedure.
Corrosion Thickness vs Coating Thickness
These are different measurements.
Question:
How much steel remains?
Use a suitable ultrasonic thickness gauge, such as the UNI-T UT345A.
Question:
How thick is the paint or protective coating?
Use a suitable coating thickness gauge, such as an appropriate UNI-T UT343-series instrument.
For corrosion-control programmes, both measurements may be useful.
Example: Factory Cooling Water Pipe
Suppose a factory maintenance team notices external corrosion on a cooling-water pipe.
They measure:
CW-01: 6.0 mm
CW-02: 5.8 mm
CW-03: 4.9 mm
The lower reading at CW-03 is verified and recorded.
During the next inspection, the team returns to the same point.
This is more useful than taking random measurements at different locations every year.
Example: Palm Oil Mill
A palm oil mill may have extensive process and utility piping.
UT345A can be considered for suitable wall-thickness measurements during maintenance activities.
Combined with good asset identification and repeatable measurement locations, the instrument can support a more structured preventive-maintenance programme.
Example: HVAC and Chilled Water
Insulated chilled-water pipes may experience deterioration that is not immediately visible.
Where inspection procedures provide suitable access to the metal surface, ultrasonic thickness measurement can provide additional information about remaining wall thickness.
The UT345A should not be assumed to measure directly through every insulation or cladding system.
Example: Marine Maintenance
Marine steel components can be exposed to aggressive environments.
Ultrasonic thickness measurement can be useful for selected maintenance checks on suitable:
Steel plates
Pipes
Tanks
Fabricated components
Official or classification-related inspections may require specific equipment, procedures and qualified personnel.
Does a Low Thickness Reading Mean the Equipment Is Unsafe?
Not automatically.
An ultrasonic thickness gauge provides measurement data.
Whether the measured thickness is acceptable can depend on:
Original thickness
Material
Equipment design
Geometry
Pressure
Temperature
Corrosion allowance
Service conditions
Applicable codes and standards
Therefore:
UT345A → Measures thickness
Engineering / inspection assessment → Determines significance
For safety-critical equipment, use appropriately qualified personnel and applicable procedures.
UT345A Does Not Identify the Cause of Corrosion
The instrument tells you the measured material thickness.
It does not tell you whether corrosion was caused by:
Water chemistry
Chemical exposure
Moisture
Flow conditions
Environmental exposure
Corrosion under insulation
Another deterioration mechanism
Finding the root cause may require additional inspection, testing and engineering analysis.
Build a Corrosion Monitoring Record
A useful record might include:
Asset: Process Pipe PP-02
Location: Pump Room
Point: UT-04
Material: Carbon Steel
Instrument: UNI-T UT345A
Thickness: 5.3 mm
Surface: Prepared
Date: Inspection date
Condition: Corrosion observed
Remarks: Reading repeated
Over time, these records become more valuable than isolated measurements.
UNI-T UT345A Troubleshooting
If you cannot obtain a stable reading on corroded metal, check:
Is the material suitable?
Is the surface too rough?
Is loose rust present?
Is suitable couplant being used?
Is the probe positioned correctly?
Is the sound velocity correct?
Is pipe curvature affecting contact?
Has the instrument been verified?
Can the reading be repeated?
If possible, test the UT345A on a suitable reference material.
If the instrument works correctly on the reference but not on the corroded component, the difficulty may be related to the application or surface condition.
Is UNI-T UT345A Suitable for Your Corrosion Inspection?
Send MTM Precision:
Photo of the corroded area
Material type
Approximate expected thickness
Pipe diameter if applicable
Surface condition
Whether paint or coating is present
Measurement objective
We can help assess whether the UNI-T UT345A Ultrasonic Thickness Gauge is suitable for the intended measurement application.
UNI-T UT345A Ultrasonic Thickness Gauge Malaysia
MTM Precision Sdn Bhd supplies UNI-T UT345A Ultrasonic Thickness Gauge for suitable material-thickness measurement and industrial maintenance applications in Malaysia.
Applications may include:
Corroded metal thickness measurement
Pipe wall-thickness measurement
Storage-tank inspection
Steel-plate measurement
Cooling-water pipe monitoring
Factory preventive maintenance
Selected marine maintenance applications
MTM Precision Sdn Bhd
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Contact MTM Precision for UNI-T UT345A Ultrasonic Thickness Gauge Malaysia, corroded metal thickness measurement, pipe-wall inspection and industrial corrosion-monitoring applications.
22 Sep 2026