UNI-T UT345A vs Benetech GM100+ Ultrasonic Thickness Gauge Malaysia

UNI-T UT345A vs Benetech GM100+ Ultrasonic Thickness Gauge Malaysia

 

If you are looking for an ultrasonic thickness gauge in Malaysia, you may come across models such as the UNI-T UT345A and Benetech GM100+.

 

Both are associated with ultrasonic material-thickness measurement, but choosing a thickness gauge should not be based only on price or measurement range.

 

The more important question is:

 

Which instrument is suitable for the material and application you actually need to measure?

 

This guide explains what Malaysian industrial users should consider before choosing between UNI-T UT345A, Benetech GM100+ or another ultrasonic thickness gauge.

 

What Is an Ultrasonic Thickness Gauge Used For?

 

An ultrasonic thickness gauge is useful when you need to determine material thickness but can access only one side of the component.

 

Typical applications include:

 

Pipe-wall thickness

 

Corrosion monitoring

 

Steel plates

 

Storage tanks

 

Fabricated metal components

 

Factory maintenance

 

HVAC piping

 

Cooling-water systems

 

Selected marine-maintenance applications

 

Instead of cutting the component, ultrasonic energy is transmitted into the material and the returning echo is used to calculate thickness.

 

UNI-T UT345A Overview

 

The UNI-T UT345A is a portable ultrasonic thickness gauge.

 

Key published specifications include:

 

Measurement range: 1.00–300.00 mm

 

Sound velocity: 1000–9999 m/s

 

Display: 2.4-inch LCD

 

Data storage: 300 groups

 

Measurement modes: Single and continuous measurement

 

Additional functions: Alarm, sound-velocity measurement and auto calibration

 

Charging: Type-C

 

The instrument is designed for suitable material-thickness and corrosion-monitoring applications.

 

What About Benetech GM100+?

 

The Benetech GM100+ is another model customers may encounter when searching for a portable ultrasonic thickness gauge.

 

However, specifications can vary between models, versions and seller listings.

 

Before comparing it directly with the UT345A, confirm the exact GM100+ specification from the supplier or current manufacturer documentation.

 

Important parameters to verify include:

 

Measurement range

 

Resolution

 

Accuracy

 

Minimum pipe diameter

 

Sound-velocity range

 

Probe specification

 

Material selection

 

Data-storage capability

 

Calibration method

 

Standard accessories

 

Do not select an instrument based only on a marketplace title.

 

UT345A vs GM100+: Start with the Application

 

Instead of asking:

 

“Which one is better?”

 

start with:

 

“What do I need to measure?”

 

For example:

 

Application A – Carbon Steel Pipe

 

Provide:

 

Pipe material

 

Diameter

 

Expected wall thickness

 

Surface condition

 

Then compare which instrument and probe configuration are suitable.

 

Application B – Storage Tank

 

Consider:

 

Tank material

 

Expected wall thickness

 

Surface coating

 

Corrosion condition

 

Required measurement records

 

Application C – Steel Plate

 

Consider:

 

Material

 

Thickness range

 

Surface condition

 

Whether the plate is installed

 

The correct choice can depend on the application rather than the brand alone.

 

Measurement Range

 

The UNI-T UT345A has a published measurement range of:

 

1.00–300.00 mm

 

This sounds broad, but maximum range should not be the only buying criterion.

 

Suppose your normal work involves:

 

4–10 mm steel pipe walls

 

Whether a meter can theoretically measure hundreds of millimetres is much less important than whether it performs appropriately on your actual pipes.

 

Minimum Pipe Capability Matters

 

Pipe measurement can be more demanding than measuring a large flat plate.

 

UNI-T publishes a lower pipe measurement specification of approximately:

 

Φ20 × 3 mm for steel

 

for the UT345A.

 

This is useful information for customers planning to measure smaller pipes.

 

When comparing with another thickness gauge, check the manufacturer's equivalent pipe specification rather than comparing only maximum thickness range.

 

Data Storage

 

The UT345A provides storage for 300 groups of data.

 

Stored information can support users who need to take multiple measurements during maintenance work.

 

This can be useful for:

 

Pipe inspection routes

 

Tank measurement points

 

Factory maintenance rounds

 

Corrosion monitoring

 

Multiple asset checks

 

If you only take occasional measurements, storage may be less important.

 

If you perform repeated inspection rounds, it can become more useful.

 

Single and Continuous Measurement

 

The UT345A supports both:

 

Single measurement

 

and

 

Continuous measurement

 

Different users may prefer different measurement workflows depending on the component and inspection procedure.

 

For maintenance departments checking multiple locations, these functions can improve practical usability.

 

Type-C Charging

 

The UT345A uses a built-in lithium battery and Type-C charging.

 

For users who regularly carry instruments around a factory or site, rechargeable operation can be convenient.

 

However, battery type should still be considered a secondary buying factor.

 

Measurement suitability comes first.

 

Sound Velocity Adjustment

 

The UT345A provides an adjustable sound-velocity range of approximately:

 

1000–9999 m/s

 

This matters because ultrasonic thickness measurement depends on the velocity of sound through the test material.

 

If the wrong velocity is used, the displayed thickness can be wrong even when the reading appears stable.

 

When comparing UT345A and GM100+, check how each instrument handles material selection and sound-velocity adjustment.

 

Accuracy Should Be Compared Carefully

 

Do not compare accuracy specifications without reading how each manufacturer defines them.

 

For the UT345A, UNI-T publishes different accuracy specifications depending on measured thickness.

 

When comparing another model, check:

 

Measurement conditions

 

Thickness range

 

Resolution

 

Accuracy formula

 

Probe used

 

Reference material

 

Two specifications may look similar on a marketplace listing while being defined differently.

 

UT345A for Pipe Corrosion Monitoring

 

For MTM Precision customers, one of the most practical reasons to purchase an ultrasonic thickness gauge is pipe-wall monitoring.

 

A maintenance team can establish locations such as:

 

UT-01 – Pump discharge

 

UT-02 – Pipe elbow

 

UT-03 – Cooling-water line

 

UT-04 – Tank outlet

 

Measurements can then be repeated during future maintenance periods.

 

This provides much more useful information than randomly checking different locations every time.

 

Example

 

Suppose a pipe gives:

 

UT-01: 6.2 mm

 

UT-02: 6.1 mm

 

UT-03: 5.2 mm

 

UT-04: 6.2 mm

 

The lower UT-03 result should be verified.

 

Check:

 

Couplant

 

Surface

 

Probe position

 

Sound velocity

 

Instrument verification

 

Measurement repeatability

 

If the lower value remains repeatable, it can be investigated according to the applicable inspection procedure.

 

Both Instruments Still Need Correct Technique

 

Buying a more expensive meter does not eliminate the need for proper measurement technique.

 

Ultrasonic thickness measurement can be affected by:

 

Surface condition

 

Loose rust

 

Scale

 

Pitting

 

Pipe curvature

 

Couplant

 

Probe contact

 

Material

 

Sound velocity

 

Calibration or verification

 

Therefore, user technique can be just as important as the instrument specification.

 

Don't Confuse Ultrasonic Thickness with Coating Thickness

 

Neither instrument should be purchased simply because you need “a thickness meter”.

 

First determine what thickness you want to measure.

 

Material Thickness

 

Examples:

 

Steel pipe wall

 

Tank wall

 

Steel plate

 

Use a suitable ultrasonic thickness gauge.

 

Coating Thickness

 

Examples:

 

Paint

 

Protective coating

 

Surface finishing

 

Use a suitable coating thickness gauge, such as an appropriate UNI-T UT343-series model.

 

These are different measurement technologies.

 

UT345A vs GM100+: Which One Should You Buy?

 

Do not choose based only on:

 

Brand

 

or:

 

Lowest price

 

Compare the actual requirement.

 

Consider:

 

Material

 

Expected thickness

 

Pipe diameter

 

Surface condition

 

Measurement range

 

Probe suitability

 

Accuracy requirement

 

Data-storage requirement

 

Measurement frequency

 

Documentation requirement

 

Local technical support

 

Budget

 

For a general industrial-maintenance customer, the best choice is the instrument whose specifications and probe configuration match the actual application.

 

When UT345A Is Particularly Attractive

 

The UT345A deserves consideration when the customer values features such as:

 

1.00–300.00 mm published measurement range

 

Adjustable sound velocity

 

300-group data storage

 

Single and continuous measurement

 

Auto calibration

 

Rechargeable battery

 

Type-C charging

 

Portable industrial use

 

Its published lower pipe measurement specification is also useful when evaluating pipe applications.

 

When Should You Consider Another Instrument?

 

Another model may be more appropriate if:

 

Your material is outside UT345A capability

 

Your pipe geometry is unsuitable

 

You require a specialised probe

 

You need specialised high-temperature measurement

 

Your job specification requires particular equipment

 

You need ultrasonic flaw detection rather than thickness measurement

 

You need a different measurement technique

 

MTM Precision prefers to check the application before recommending a model.

 

What Information Should You Send MTM?

 

If you are deciding between UNI-T UT345A and Benetech GM100+, send:

 

Material:

Carbon steel / stainless steel / aluminium / other

 

Application:

Pipe / tank / plate / machinery

 

Expected thickness:

Example: 5–8 mm

 

Pipe diameter:

If applicable

 

Surface:

Clean / painted / rusty / heavily corroded

 

Usage:

Occasional / routine maintenance / inspection

 

Quantity:

Number of units required

 

A photo of the actual component is even better.

 

Our Selection Approach

 

For MTM Precision, the question is not simply:

 

“UT345A or GM100+?”

 

It is:

 

“Which instrument is suitable for this customer's measurement?”

 

If a lower-cost instrument already meets the actual requirement, there may be no reason to overspecify.

 

If the application requires functions or capabilities beyond a basic instrument, price alone should not determine the purchase.

 

UNI-T UT345A vs Benetech GM100+ Malaysia

 

MTM Precision Sdn Bhd supplies industrial measuring instruments for pipe-wall measurement, corrosion monitoring and factory-maintenance applications in Malaysia.

 

Contact us with your application details if you need help comparing ultrasonic thickness gauges.

 

MTM Precision Sdn Bhd

 

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Tel: 03-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com

Website: www.mtmpre.com.my

 

For UNI-T UT345A vs Benetech GM100+ Malaysia, send MTM Precision your material, expected thickness, pipe diameter and application photo so we can help check which ultrasonic thickness gauge is more suitable.


 

22 Sep 2026