UNI-T UT345A vs Benetech GM100+ Ultrasonic Thickness Gauge Malaysia
UNI-T UT345A vs Benetech GM100+ Ultrasonic Thickness Gauge Malaysia
If you are looking for an ultrasonic thickness gauge in Malaysia, you may come across models such as the UNI-T UT345A and Benetech GM100+.
Both are associated with ultrasonic material-thickness measurement, but choosing a thickness gauge should not be based only on price or measurement range.
The more important question is:
Which instrument is suitable for the material and application you actually need to measure?
This guide explains what Malaysian industrial users should consider before choosing between UNI-T UT345A, Benetech GM100+ or another ultrasonic thickness gauge.
What Is an Ultrasonic Thickness Gauge Used For?
An ultrasonic thickness gauge is useful when you need to determine material thickness but can access only one side of the component.
Typical applications include:
Pipe-wall thickness
Corrosion monitoring
Steel plates
Storage tanks
Fabricated metal components
Factory maintenance
HVAC piping
Cooling-water systems
Selected marine-maintenance applications
Instead of cutting the component, ultrasonic energy is transmitted into the material and the returning echo is used to calculate thickness.
UNI-T UT345A Overview
The UNI-T UT345A is a portable ultrasonic thickness gauge.
Key published specifications include:
Measurement range: 1.00–300.00 mm
Sound velocity: 1000–9999 m/s
Display: 2.4-inch LCD
Data storage: 300 groups
Measurement modes: Single and continuous measurement
Additional functions: Alarm, sound-velocity measurement and auto calibration
Charging: Type-C
The instrument is designed for suitable material-thickness and corrosion-monitoring applications.
What About Benetech GM100+?
The Benetech GM100+ is another model customers may encounter when searching for a portable ultrasonic thickness gauge.
However, specifications can vary between models, versions and seller listings.
Before comparing it directly with the UT345A, confirm the exact GM100+ specification from the supplier or current manufacturer documentation.
Important parameters to verify include:
Measurement range
Resolution
Accuracy
Minimum pipe diameter
Sound-velocity range
Probe specification
Material selection
Data-storage capability
Calibration method
Standard accessories
Do not select an instrument based only on a marketplace title.
UT345A vs GM100+: Start with the Application
Instead of asking:
“Which one is better?”
start with:
“What do I need to measure?”
For example:
Application A – Carbon Steel Pipe
Provide:
Pipe material
Diameter
Expected wall thickness
Surface condition
Then compare which instrument and probe configuration are suitable.
Application B – Storage Tank
Consider:
Tank material
Expected wall thickness
Surface coating
Corrosion condition
Required measurement records
Application C – Steel Plate
Consider:
Material
Thickness range
Surface condition
Whether the plate is installed
The correct choice can depend on the application rather than the brand alone.
Measurement Range
The UNI-T UT345A has a published measurement range of:
1.00–300.00 mm
This sounds broad, but maximum range should not be the only buying criterion.
Suppose your normal work involves:
4–10 mm steel pipe walls
Whether a meter can theoretically measure hundreds of millimetres is much less important than whether it performs appropriately on your actual pipes.
Minimum Pipe Capability Matters
Pipe measurement can be more demanding than measuring a large flat plate.
UNI-T publishes a lower pipe measurement specification of approximately:
Φ20 × 3 mm for steel
for the UT345A.
This is useful information for customers planning to measure smaller pipes.
When comparing with another thickness gauge, check the manufacturer's equivalent pipe specification rather than comparing only maximum thickness range.
Data Storage
The UT345A provides storage for 300 groups of data.
Stored information can support users who need to take multiple measurements during maintenance work.
This can be useful for:
Pipe inspection routes
Tank measurement points
Factory maintenance rounds
Corrosion monitoring
Multiple asset checks
If you only take occasional measurements, storage may be less important.
If you perform repeated inspection rounds, it can become more useful.
Single and Continuous Measurement
The UT345A supports both:
Single measurement
and
Continuous measurement
Different users may prefer different measurement workflows depending on the component and inspection procedure.
For maintenance departments checking multiple locations, these functions can improve practical usability.
Type-C Charging
The UT345A uses a built-in lithium battery and Type-C charging.
For users who regularly carry instruments around a factory or site, rechargeable operation can be convenient.
However, battery type should still be considered a secondary buying factor.
Measurement suitability comes first.
Sound Velocity Adjustment
The UT345A provides an adjustable sound-velocity range of approximately:
1000–9999 m/s
This matters because ultrasonic thickness measurement depends on the velocity of sound through the test material.
If the wrong velocity is used, the displayed thickness can be wrong even when the reading appears stable.
When comparing UT345A and GM100+, check how each instrument handles material selection and sound-velocity adjustment.
Accuracy Should Be Compared Carefully
Do not compare accuracy specifications without reading how each manufacturer defines them.
For the UT345A, UNI-T publishes different accuracy specifications depending on measured thickness.
When comparing another model, check:
Measurement conditions
Thickness range
Resolution
Accuracy formula
Probe used
Reference material
Two specifications may look similar on a marketplace listing while being defined differently.
UT345A for Pipe Corrosion Monitoring
For MTM Precision customers, one of the most practical reasons to purchase an ultrasonic thickness gauge is pipe-wall monitoring.
A maintenance team can establish locations such as:
UT-01 – Pump discharge
UT-02 – Pipe elbow
UT-03 – Cooling-water line
UT-04 – Tank outlet
Measurements can then be repeated during future maintenance periods.
This provides much more useful information than randomly checking different locations every time.
Example
Suppose a pipe gives:
UT-01: 6.2 mm
UT-02: 6.1 mm
UT-03: 5.2 mm
UT-04: 6.2 mm
The lower UT-03 result should be verified.
Check:
Couplant
Surface
Probe position
Sound velocity
Instrument verification
Measurement repeatability
If the lower value remains repeatable, it can be investigated according to the applicable inspection procedure.
Both Instruments Still Need Correct Technique
Buying a more expensive meter does not eliminate the need for proper measurement technique.
Ultrasonic thickness measurement can be affected by:
Surface condition
Loose rust
Scale
Pitting
Pipe curvature
Couplant
Probe contact
Material
Sound velocity
Calibration or verification
Therefore, user technique can be just as important as the instrument specification.
Don't Confuse Ultrasonic Thickness with Coating Thickness
Neither instrument should be purchased simply because you need “a thickness meter”.
First determine what thickness you want to measure.
Material Thickness
Examples:
Steel pipe wall
Tank wall
Steel plate
Use a suitable ultrasonic thickness gauge.
Coating Thickness
Examples:
Paint
Protective coating
Surface finishing
Use a suitable coating thickness gauge, such as an appropriate UNI-T UT343-series model.
These are different measurement technologies.
UT345A vs GM100+: Which One Should You Buy?
Do not choose based only on:
Brand
or:
Lowest price
Compare the actual requirement.
Consider:
Material
Expected thickness
Pipe diameter
Surface condition
Measurement range
Probe suitability
Accuracy requirement
Data-storage requirement
Measurement frequency
Documentation requirement
Local technical support
Budget
For a general industrial-maintenance customer, the best choice is the instrument whose specifications and probe configuration match the actual application.
When UT345A Is Particularly Attractive
The UT345A deserves consideration when the customer values features such as:
1.00–300.00 mm published measurement range
Adjustable sound velocity
300-group data storage
Single and continuous measurement
Auto calibration
Rechargeable battery
Type-C charging
Portable industrial use
Its published lower pipe measurement specification is also useful when evaluating pipe applications.
When Should You Consider Another Instrument?
Another model may be more appropriate if:
Your material is outside UT345A capability
Your pipe geometry is unsuitable
You require a specialised probe
You need specialised high-temperature measurement
Your job specification requires particular equipment
You need ultrasonic flaw detection rather than thickness measurement
You need a different measurement technique
MTM Precision prefers to check the application before recommending a model.
What Information Should You Send MTM?
If you are deciding between UNI-T UT345A and Benetech GM100+, send:
Material:
Carbon steel / stainless steel / aluminium / other
Application:
Pipe / tank / plate / machinery
Expected thickness:
Example: 5–8 mm
Pipe diameter:
If applicable
Surface:
Clean / painted / rusty / heavily corroded
Usage:
Occasional / routine maintenance / inspection
Quantity:
Number of units required
A photo of the actual component is even better.
Our Selection Approach
For MTM Precision, the question is not simply:
“UT345A or GM100+?”
It is:
“Which instrument is suitable for this customer's measurement?”
If a lower-cost instrument already meets the actual requirement, there may be no reason to overspecify.
If the application requires functions or capabilities beyond a basic instrument, price alone should not determine the purchase.
UNI-T UT345A vs Benetech GM100+ Malaysia
MTM Precision Sdn Bhd supplies industrial measuring instruments for pipe-wall measurement, corrosion monitoring and factory-maintenance applications in Malaysia.
Contact us with your application details if you need help comparing ultrasonic thickness gauges.
MTM Precision Sdn Bhd
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
For UNI-T UT345A vs Benetech GM100+ Malaysia, send MTM Precision your material, expected thickness, pipe diameter and application photo so we can help check which ultrasonic thickness gauge is more suitable.
22 Sep 2026