Motor Current Increasing Over Time: What Should Maintenance Check Malaysia
Motor Current Increasing Over Time: What Should Maintenance Check Malaysia
Your maintenance records show:
Month 1 → 7.1 A
Month 2 → 7.2 A
Month 3 → 7.5 A
Month 4 → 8.2 A
The motor is still running, but the current is gradually increasing.
What should maintenance check?
The first mistake is to immediately conclude:
“The motor is failing.”
Increasing motor current can be related to the electrical system, motor, mechanical load, driven equipment, VFD settings or process condition.
A better approach is to investigate the complete system:
Power Supply → VFD / Starter → Motor → Coupling → Machine → Process
A clamp meter such as the TASI TA813B+ True RMS Digital Clamp Meter can provide electrical data, but the current reading should be interpreted together with operating conditions and other maintenance measurements.
First Question: Are You Comparing the Same Operating Condition?
Before investigating the equipment, verify the data.
Suppose:
Last Month: 6.5 A
Today: 8.0 A
That looks like a significant increase.
But perhaps:
Last Month → VFD 35 Hz
Today → VFD 50 Hz
The operating conditions are different.
Therefore, before comparing current trends, check:
VFD frequency
Motor speed
Production load
Pump flow
Valve position
Compressor loading
Process condition
Equipment operating mode
Always try to compare:
Similar Condition ↔ Similar Condition
Check L1, L2 and L3
For a three-phase motor, do not record only one phase.
Measure the appropriate phase conductors individually.
Record:
PhasePreviousCurrentL1RecordRecordL2RecordRecordL3RecordRecord
Then ask:
Are all three currents increasing?
or:
Is only one phase significantly different?
These observations can guide the next stage of investigation.
If All Three Phases Increase
If the currents increase together under comparable operating conditions, investigate the complete load.
Possible areas can include:
Increased mechanical load
Process changes
Pump condition
Compressor loading
Fan loading
Motor condition
Electrical supply
VFD operation
Do not automatically assume the motor is the cause.
If One Phase Is Different
If one phase differs significantly from the others, investigate further.
Possible areas can include:
Supply condition
Electrical connections
Starter / contactor
VFD
Motor
Measurement method
Use the motor, drive and electrical-system manufacturer's specifications when evaluating the results.
A clamp meter can identify that a difference exists; it does not automatically identify the root cause.
Check Supply Voltage
Current should not be interpreted independently of the electrical supply.
If the motor's operating condition has changed, check whether the relevant supply conditions have also changed.
Depending on the system and measurement point, technicians may need to investigate:
Voltage
Phase conditions
Connections
Drive input
Drive output
Protection equipment
Use appropriate instruments and procedures for the actual installation.
Check the VFD
For VFD-driven motors, record the operating frequency.
A useful maintenance record may contain:
ParameterBaselineCurrentVFD FrequencyRecordRecordL1 CurrentRecordRecordL2 CurrentRecordRecordL3 CurrentRecordRecordMotor SpeedRecordRecordVibrationRecordRecordTemperatureRecordRecord
If the frequency has changed, the current may also change.
Do not compare VFD equipment without considering operating frequency.
Read the VFD Fault History
If the drive has been producing alarms or trips, review:
Current fault code
Previous fault history
Operating parameters
Manufacturer documentation
Do not replace a VFD simply because motor current has increased.
Use the drive's diagnostic information together with physical measurements.
Check the Mechanical Load
The motor exists to drive something.
That “something” can change.
Examples include:
Pump
Fan
Compressor
Conveyor
Mixer
Production machine
If the mechanical load increases, the motor may require more electrical power.
Therefore:
Higher Motor Current
can sometimes be a symptom of:
Higher Mechanical / Process Load
rather than an electrical fault.
Example: Water Pump
Consider:
VFD → Motor → Coupling → Pump → Process
Motor current has increased from the historical baseline.
Check:
VFD Frequency
↓
Motor Current
↓
Motor / Coupling
↓
Pump Condition
↓
Valve / Flow / Process Condition
The problem may not be inside the motor.
Example: Pump Current and Vibration Both Increase
Suppose:
Current ↑
and
Vibration ↑
This provides more information than current alone.
The maintenance team should investigate the complete motor-pump system.
Possible areas may include:
Mechanical loading
Alignment
Bearing condition
Pump condition
Process changes
Further testing is required before identifying the actual cause.
Example: Current Increases but Vibration Is Stable
Now suppose:
Current ↑
but
Vibration remains close to baseline
Do not ignore the change.
Investigate:
Electrical conditions
Process load
VFD frequency
Supply
Production condition
Motor loading
The stable vibration reading is useful evidence, but it does not rule out every mechanical or electrical problem.
Example: Vibration Increases but Current Is Stable
Another condition is:
Current Stable
Vibration ↑
This may shift attention toward mechanical condition.
Possible investigation areas can include:
Bearings
Alignment
Imbalance
Looseness
Driven equipment
Again, vibration analysis should be interpreted according to the machine and measurement method.
Add Temperature to the Investigation
Temperature can provide another useful data point.
For example:
Current ↑
Vibration ↑
Temperature ↑
This combination deserves closer attention.
A thermal camera can help inspect temperature patterns around:
Electrical connections
Breakers
Terminals
Motor body
Bearings
VFD cabinet
Do not diagnose a fault from temperature alone.
Compare against load, baseline and equipment condition.
Check Motor Speed
For VFD-controlled equipment, motor speed can change.
A tachometer can provide additional confirmation.
Record:
VFD Frequency
Motor Speed
Current
This helps determine whether measurements are being compared under similar operating conditions.
Example: Air Compressor
An air compressor shows increasing current over several inspections.
Before assuming motor failure, consider:
Compressor loading
Operating pressure
Running condition
VFD frequency if applicable
Mechanical condition
Cooling
Vibration
Temperature
The compressor is a system, not just a motor.
Example: AHU Fan
Suppose an AHU fan motor current increases.
Check:
VFD frequency
Fan speed
Filter condition
Airflow conditions
Mechanical condition
Vibration
Electrical measurements
Changes in system resistance and operating conditions can affect fan load.
Example: Cooling Tower Fan
For cooling-tower fans, compare measurements under similar conditions.
Record:
Frequency
Speed
Current
Vibration
Temperature
This makes the historical data much more useful.
Check Connections
Electrical connections should also be included in maintenance inspection.
Depending on the installation, technicians may inspect:
Terminals
Contactors
Breakers
Cable connections
Motor terminals
VFD connections
Thermal inspection can complement electrical measurements when looking for abnormal heating patterns.
All energized-panel work should follow site electrical-safety procedures.
What About Inrush Current?
If the problem occurs during motor startup rather than normal running, investigate startup behaviour separately.
For conventional motor starting:
Startup → Inrush Current
Running → Running Current
The TA813B+ includes an Inrush Current function.
However, a VFD-controlled motor does not necessarily have the same startup behaviour as a direct-on-line motor.
Always identify the starting method before interpreting startup current.
Do Not Increase the Breaker Size Just Because Current Is High
If a motor starts tripping protection, simply installing a larger breaker is not a proper troubleshooting method.
Protection devices are selected according to electrical-system design, equipment requirements and applicable standards.
First determine:
Why has the operating condition changed?
Protection changes should only be made by appropriately qualified personnel after proper assessment.
Build a Trend, Not Just a Reading
A useful motor history may look like:
MonthFrequencyL1L2L3VibrationTemperatureJanRecordRecordRecordRecordRecordRecordFebRecordRecordRecordRecordRecordRecordMarRecordRecordRecordRecordRecordRecordAprRecordRecordRecordRecordRecordRecord
The trend can help maintenance teams identify when equipment begins moving away from its established baseline.
Current Trend + Vibration Trend
This is particularly useful for rotating equipment.
Current Stable / Vibration Stable
Continue monitoring according to the maintenance plan.
Current Increasing / Vibration Stable
Investigate electrical, load and process conditions.
Current Stable / Vibration Increasing
Investigate mechanical condition.
Current Increasing / Vibration Increasing
Investigate the complete electrical and mechanical system.
These are troubleshooting directions—not final diagnoses.
Current Trend + Thermal Trend
Electrical data can also be combined with thermal inspection.
For example:
Motor Current Increasing
Terminal Temperature Increasing
may justify closer inspection of the electrical system.
Meanwhile:
Motor Current Increasing
Bearing Area Temperature Increasing
may point the maintenance investigation in another direction.
Additional testing is required before concluding the root cause.
Use Multiple Instruments
For motor and pump troubleshooting:
TASI TA813B+ Clamp Meter
→ Current / voltage / frequency / electrical condition
Vibration Meter
→ Mechanical vibration
Thermal Camera
→ Temperature patterns
Tachometer
→ Rotational speed
The objective is to correlate information.
Useful Vibration Meter Options
MTM Precision also supplies vibration meters suitable for general rotating-equipment maintenance, including:
Landtek VM6310
Landtek VM6360
Landtek VM6380
Wintact WT63A / WT63B
Benetech GM63B
Smart Sensor AR63B
These instruments can complement clamp-meter measurements when monitoring motors, pumps, fans and compressors.
Why TA813B+ for Motor Troubleshooting?
The TASI TA813B+ provides:
True RMS
AC Current
DC Current
Inrush Current
VFD Voltage
Frequency
AC/DC Voltage
DC Zero Adjustment
High/Low-Z
Relative Value
Inductance
Temperature
Resistance
Continuity
NCV
For motor maintenance, functions such as current, True RMS, Inrush, frequency and VFD voltage are particularly relevant.
Motor Current Increasing: A Practical Workflow
When current begins increasing:
Confirm Measurement
↓
Compare Same Operating Condition
↓
Measure L1 / L2 / L3
↓
Check Frequency / Speed
↓
Review Supply / VFD
↓
Check Mechanical Load
↓
Measure Vibration
↓
Check Temperature
↓
Review Process Condition
↓
Compare Historical Trend
↓
Investigate Root Cause
This is more reliable than replacing the motor based on one current reading.
Important Electrical Safety
Motor-current measurements often involve energized industrial equipment.
Only appropriately trained personnel should perform these measurements.
Always follow:
Site electrical procedures
PPE requirements
Meter CAT ratings
Instrument voltage/current limits
Lockout/tagout requirements
VFD manufacturer procedures
Equipment manufacturer instructions
Do not open, adjust or work inside energized equipment merely to obtain a measurement unless the procedure is authorized and can be performed safely.
Motor and Pump Troubleshooting Instruments Malaysia
Is your motor, pump, compressor, AHU or cooling-tower fan current increasing over time?
MTM Precision can support maintenance teams with instruments for:
Electrical Measurement
→ TASI TA813B+ Clamp Meter
Mechanical Condition
→ Vibration Meter
Temperature Inspection
→ Thermal Camera
Speed Measurement
→ Tachometer
Combining electrical and mechanical data can provide better maintenance information than relying on a single measurement.
MTM Precision Sdn Bhd
Showroom & Service Centre
No 29-1 & 2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Supporting factory, facility and industrial maintenance customers throughout Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.
27 Sep 2026