TASI TA813B+ Applications: 10 Jobs You Can Use It For Malaysia

TASI TA813B+ Applications: 10 Jobs You Can Use It For Malaysia

 

What can you actually use the TASI TA813B+ True RMS Digital Clamp Meter for?

 

A modern clamp meter is no longer used only to check basic AC current.

 

For technicians working with motors, pumps, VFDs, HVAC systems, compressors, batteries, DC power supplies, automation and factory equipment, different measurement functions may be required throughout the same working day.

 

The TASI TA813B+ combines functions including:

 

True RMS

 

AC Current

 

DC Current

 

AC/DC Voltage

 

Inrush Current

 

VFD Voltage

 

Frequency / Duty Cycle

 

Resistance

 

Capacitance

 

Temperature

 

Continuity / Diode

 

High / Low Impedance Voltage

 

NCV

 

Live / Neutral Identification

 

Relative Value

 

DC Zero Adjustment

 

Inductance

 

Auto Ranging

 

LED Flashlight

 

Here are 10 practical applications where an AC/DC clamp meter such as the TA813B+ can support electrical and industrial maintenance work in Malaysia.

 

1. Three-Phase Motor Current Measurement

 

One of the most common clamp-meter applications is checking motor current.

 

For a three-phase motor, technicians can measure the appropriate phase conductors individually:

 

L1 → Measure

 

L2 → Measure

 

L3 → Measure

 

Record the results:

 

PhaseCurrentL1RecordL2RecordL3Record

 

The readings can then be compared with:

 

Previous measurements

 

Motor information

 

Equipment load

 

Operating conditions

 

VFD frequency where applicable

 

A difference between phase-current readings should be investigated rather than automatically treated as proof of motor failure.

 

2. Pump Electrical Troubleshooting

 

A pump should be considered as a complete system:

 

Power Supply → Starter / VFD → Motor → Coupling → Pump → Process

 

The TA813B+ can support electrical checks such as:

 

Motor current

 

Voltage

 

Frequency

 

Inrush

 

VFD-related measurements

 

But current alone cannot tell you whether the root cause is electrical, mechanical or process-related.

 

For more complete troubleshooting, combine electrical measurements with:

 

Vibration

 

Temperature

 

Speed

 

Process Information

 

3. VFD Motor Maintenance

 

Variable Frequency Drives are common in:

 

Factories

 

Pumps

 

HVAC systems

 

AHUs

 

Cooling towers

 

Compressors

 

Fans

 

Process machinery

 

A simplified system is:

 

Power Supply → VFD → Motor → Mechanical Load

 

For VFD-related maintenance, useful functions can include:

 

True RMS

 

Current

 

Frequency

 

VFD voltage

 

The TA813B+ provides these functions for broader troubleshooting.

 

Always consider the measurement point, meter specifications and VFD manufacturer's procedures.

 

4. Motor Inrush Current Testing

 

When a motor has a startup problem, normal running current may not tell the complete story.

 

Consider:

 

Motor Starts → Inrush Current

 

Motor Runs → Running Current

 

The TA813B+ includes an Inrush Current function.

 

This can be useful when investigating startup behaviour in applications such as:

 

Pumps

 

Compressors

 

Fans

 

Motors

 

HVAC equipment

 

However, startup characteristics depend on the starting method.

 

A VFD-controlled motor should not automatically be interpreted in the same way as a direct-on-line motor.

 

5. HVAC Electrical Troubleshooting

 

HVAC systems contain many electrical loads.

 

Examples include:

 

Compressors

 

Condenser fans

 

AHU fans

 

FCU systems

 

Chilled-water pumps

 

Cooling-tower fans

 

VFDs

 

Electrical control panels

 

A technician may use the TA813B+ for general electrical measurements around suitable HVAC equipment.

 

For example:

 

Complaint: Compressor Does Not Start

 

↓

 

Check Electrical Supply

 

↓

 

Investigate Startup Condition

 

↓

 

Check Running Current if Operating

 

↓

 

Compare with Equipment Information

 

Current is useful evidence, but refrigeration-system problems cannot be diagnosed from electrical current alone.

 

6. Air Compressor Maintenance

 

Air compressors combine electrical and mechanical systems.

 

Possible maintenance measurements include:

 

Startup current

 

Running current

 

Voltage

 

VFD frequency

 

Temperature

 

Vibration

 

Suppose compressor current gradually increases.

 

Before concluding that the motor is defective, investigate:

 

Electrical Condition

 

Compressor Load

 

Mechanical Condition

 

Operating Pressure / Process

 

Temperature

 

A clamp meter becomes more valuable when its measurements are combined with other maintenance information.

 

7. Battery and DC System Testing

 

One major advantage of the TA813B+ over an AC-only clamp meter is DC current measurement.

 

This makes it relevant to applications such as:

 

Battery systems

 

DC power supplies

 

Industrial control systems

 

Automation

 

Inverter systems

 

Other suitable DC circuits

 

Before measuring DC current:

 

Select DC Current

 

↓

 

Keep Clamp Clear

 

↓

 

Perform DC Zero Adjustment

 

↓

 

Clamp Appropriate Individual Conductor

 

↓

 

Measure

 

Do not clamp positive and negative conductors together when the objective is to measure normal circuit current.

 

Their magnetic fields can oppose each other and produce a very low reading.

 

8. Solar and Inverter Troubleshooting

 

A simplified solar power path is:

 

PV Modules → DC Circuit → Inverter → AC Circuit → Load

 

This means technicians may encounter both:

 

DC

 

and

 

AC

 

within the same overall system.

 

An AC/DC clamp meter can therefore provide additional flexibility for general troubleshooting.

 

The TA813B+ can support suitable AC/DC electrical measurements within its specifications.

 

However, it does not replace specialized solar instruments required for tasks such as:

 

PV insulation testing

 

I-V curve testing

 

Irradiance measurement

 

Dedicated commissioning tests

 

Use instruments according to the actual solar test requirement.

 

9. Industrial Automation and DC Control Panels

 

Modern factory machinery frequently combines AC and DC systems.

 

For example:

 

AC Supply

 

↓

 

DC Power Supply

 

↓

 

PLC

 

↓

 

Sensors / Relays / Controllers

 

The maintenance technician may need to work on both sides of the system.

 

This is where an AC/DC clamp meter can provide greater flexibility than an AC-only model.

 

Possible measurements can include:

 

AC voltage

 

DC voltage

 

AC current

 

DC current

 

Frequency

 

Resistance

 

Continuity

 

The actual test method depends on the circuit and equipment.

 

10. Factory Preventive Maintenance

 

The TA813B+ can also become part of a preventive-maintenance program.

 

Instead of using the meter only after equipment fails:

 

Measure While Healthy

 

↓

 

Record Baseline

 

↓

 

Repeat Measurement

 

↓

 

Compare Trend

 

↓

 

Investigate Change

 

For example:

 

EquipmentCurrentFrequencyVibrationTemperaturePump 01RecordRecordRecordRecordCompressor 01RecordRecordRecordRecordAHU Fan 01RecordRecordRecordRecordProcess Motor 01RecordRecordRecordRecord

 

Historical data can provide more context than an isolated measurement.

 

Bonus Application: Ghost Voltage Investigation

 

Unexpected voltage can sometimes appear because of capacitive coupling or other circuit conditions.

 

The TA813B+ provides High / Low Impedance voltage measurement.

 

Low-Z can help technicians investigate suspected ghost or phantom voltage.

 

However:

 

Never assume unexpected voltage is harmless.

 

Unexpected voltage should be treated seriously until properly investigated using appropriate electrical-safety procedures.

 

Bonus Application: NCV Screening

 

The TA813B+ also provides NCV — Non-Contact Voltage detection.

 

This can be useful as a preliminary indication that AC voltage may be present.

 

However:

 

NCV ≠ Proof of Safe Isolation

 

NCV should not be used as the sole method for proving that a conductor or circuit is safe to touch.

 

Follow proper electrical verification procedures.

 

Why AC/DC Current Matters

 

Consider three technicians.

 

Technician A

 

Works mainly with conventional AC motors.

 

An AC clamp meter may cover many routine measurements.

 

Technician B

 

Works with:

 

Motors

 

VFDs

 

Pumps

 

HVAC

 

Functions such as True RMS, Inrush and VFD-related measurement become more relevant.

 

Technician C

 

Works with:

 

Motors

 

Batteries

 

DC power supplies

 

Automation

 

Inverters

 

Solar systems

 

An AC/DC clamp meter becomes considerably more flexible.

 

This is where the TA813B+ fits particularly well.

 

TASI TA813A+ vs TA813B+

 

Within the TA813 series, application should determine the choice.

 

Function / ApplicationTA813A+TA813B+AC CurrentYesYesTrue RMSYesYesInrush CurrentYesYesVFD VoltageYesYesAC/DC VoltageYesYesDC Current—YesDC Zero Adjustment—YesRelative Value—YesInductance—Yes

 

If the technician mainly needs AC current measurement, the TA813A+ may already cover the requirement.

 

If the work includes DC current and broader mixed AC/DC applications, the TA813B+ provides additional capability.

 

TA813B+ Is Not a Dedicated Leakage Current Clamp

 

Another important distinction:

 

General Clamp Meter ≠ Leakage Current Clamp

 

The TA813B+ is primarily positioned for general electrical current and troubleshooting applications.

 

If the requirement is to measure very small leakage or residual currents, select an instrument specifically designed with the necessary range, resolution and sensitivity.

 

Similarly:

 

Leakage Current Clamp

 

and

 

Insulation Resistance Tester

 

perform different tests.

 

Choose the instrument according to the actual measurement objective.

 

TA813B+ + Vibration Meter

 

For rotating equipment:

 

Clamp Meter

 

→ Electrical load

 

Vibration Meter

 

→ Mechanical vibration

 

This combination is particularly useful for:

 

Motors

 

Pumps

 

Compressors

 

Fans

 

Cooling towers

 

Production machinery

 

MTM Precision vibration meter options include:

 

Landtek VM6310

 

Landtek VM6360

 

Landtek VM6380

 

Wintact WT63A / WT63B

 

Benetech GM63B

 

Smart Sensor AR63B

 

TA813B+ + Thermal Camera

 

Add thermal inspection for:

 

Electrical panels

 

Breakers

 

Terminals

 

Contactors

 

VFD cabinets

 

Motors

 

Bearings

 

Now the maintenance team can compare:

 

Current

 

Vibration

 

Temperature

 

This provides much better context than one measurement alone.

 

TA813B+ + Tachometer

 

A tachometer adds:

 

Rotational Speed

 

This is especially useful for VFD-controlled:

 

Pumps

 

Fans

 

Motors

 

Process equipment

 

A useful condition-monitoring record can therefore contain:

 

Current + Frequency + Speed + Vibration + Temperature

 

Who Should Consider the TASI TA813B+?

 

The TA813B+ is particularly relevant to:

 

Electricians

 

Factory maintenance technicians

 

Facility maintenance teams

 

HVAC technicians

 

Motor service technicians

 

Pump maintenance technicians

 

Automation technicians

 

Electrical contractors

 

M&E contractors

 

Industrial service companies

 

It is especially useful where technicians encounter a combination of AC and DC electrical systems.

 

A Practical Factory Toolkit

 

Instead of looking for one instrument that does everything, build a toolkit according to the problem.

 

TASI TA813B+ Clamp Meter

 

→ Electrical current / voltage / frequency

 

Vibration Meter

 

→ Mechanical condition

 

Thermal Camera

 

→ Temperature patterns

 

Tachometer

 

→ Speed

 

Insulation Resistance Tester

 

→ Insulation resistance

 

Leakage Current Clamp

 

→ Small residual / leakage current

 

Different instruments answer different questions.

 

Important Electrical Safety

 

The TA813B+ is specified for CAT III 1000V applications according to the manufacturer's series information, but the instrument's rating does not replace safe working procedures.

 

Before measurement, always verify:

 

Correct measurement mode

 

Instrument condition

 

Jaw condition

 

Test lead condition

 

Voltage/current limits

 

Measurement category

 

PPE requirements

 

Site procedures

 

Equipment manufacturer instructions

 

Measurements on energized industrial systems should only be performed by appropriately trained personnel.

 

VFD, battery and solar systems can also contain hazardous stored energy even when certain equipment has been switched off.

 

TASI TA813B+ True RMS AC/DC Clamp Meter Malaysia

 

The TASI TA813B+ True RMS Digital Clamp Meter can support a wide range of electrical and industrial maintenance applications including:

 

Motor

 

Pump

 

VFD

 

HVAC

 

Air Compressor

 

Battery

 

DC Power Supply

 

Solar / Inverter

 

Automation

 

Factory Preventive Maintenance

 

For customers who are not sure whether they need the TA813A+ or TA813B+, MTM Precision can help compare the required functions according to the actual application.

 

MTM Precision Sdn Bhd

 

Showroom & Service Centre

No 29-1 & 2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Tel: 03-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com

Website: www.mtmpre.com.my

 

Supporting electrical, factory, HVAC and industrial maintenance customers throughout Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.


 

27 Sep 2026