TASI TA813B+ Applications: 10 Jobs You Can Use It For Malaysia
TASI TA813B+ Applications: 10 Jobs You Can Use It For Malaysia
What can you actually use the TASI TA813B+ True RMS Digital Clamp Meter for?
A modern clamp meter is no longer used only to check basic AC current.
For technicians working with motors, pumps, VFDs, HVAC systems, compressors, batteries, DC power supplies, automation and factory equipment, different measurement functions may be required throughout the same working day.
The TASI TA813B+ combines functions including:
True RMS
AC Current
DC Current
AC/DC Voltage
Inrush Current
VFD Voltage
Frequency / Duty Cycle
Resistance
Capacitance
Temperature
Continuity / Diode
High / Low Impedance Voltage
NCV
Live / Neutral Identification
Relative Value
DC Zero Adjustment
Inductance
Auto Ranging
LED Flashlight
Here are 10 practical applications where an AC/DC clamp meter such as the TA813B+ can support electrical and industrial maintenance work in Malaysia.
1. Three-Phase Motor Current Measurement
One of the most common clamp-meter applications is checking motor current.
For a three-phase motor, technicians can measure the appropriate phase conductors individually:
L1 → Measure
L2 → Measure
L3 → Measure
Record the results:
PhaseCurrentL1RecordL2RecordL3Record
The readings can then be compared with:
Previous measurements
Motor information
Equipment load
Operating conditions
VFD frequency where applicable
A difference between phase-current readings should be investigated rather than automatically treated as proof of motor failure.
2. Pump Electrical Troubleshooting
A pump should be considered as a complete system:
Power Supply → Starter / VFD → Motor → Coupling → Pump → Process
The TA813B+ can support electrical checks such as:
Motor current
Voltage
Frequency
Inrush
VFD-related measurements
But current alone cannot tell you whether the root cause is electrical, mechanical or process-related.
For more complete troubleshooting, combine electrical measurements with:
Vibration
Temperature
Speed
Process Information
3. VFD Motor Maintenance
Variable Frequency Drives are common in:
Factories
Pumps
HVAC systems
AHUs
Cooling towers
Compressors
Fans
Process machinery
A simplified system is:
Power Supply → VFD → Motor → Mechanical Load
For VFD-related maintenance, useful functions can include:
True RMS
Current
Frequency
VFD voltage
The TA813B+ provides these functions for broader troubleshooting.
Always consider the measurement point, meter specifications and VFD manufacturer's procedures.
4. Motor Inrush Current Testing
When a motor has a startup problem, normal running current may not tell the complete story.
Consider:
Motor Starts → Inrush Current
Motor Runs → Running Current
The TA813B+ includes an Inrush Current function.
This can be useful when investigating startup behaviour in applications such as:
Pumps
Compressors
Fans
Motors
HVAC equipment
However, startup characteristics depend on the starting method.
A VFD-controlled motor should not automatically be interpreted in the same way as a direct-on-line motor.
5. HVAC Electrical Troubleshooting
HVAC systems contain many electrical loads.
Examples include:
Compressors
Condenser fans
AHU fans
FCU systems
Chilled-water pumps
Cooling-tower fans
VFDs
Electrical control panels
A technician may use the TA813B+ for general electrical measurements around suitable HVAC equipment.
For example:
Complaint: Compressor Does Not Start
↓
Check Electrical Supply
↓
Investigate Startup Condition
↓
Check Running Current if Operating
↓
Compare with Equipment Information
Current is useful evidence, but refrigeration-system problems cannot be diagnosed from electrical current alone.
6. Air Compressor Maintenance
Air compressors combine electrical and mechanical systems.
Possible maintenance measurements include:
Startup current
Running current
Voltage
VFD frequency
Temperature
Vibration
Suppose compressor current gradually increases.
Before concluding that the motor is defective, investigate:
Electrical Condition
Compressor Load
Mechanical Condition
Operating Pressure / Process
Temperature
A clamp meter becomes more valuable when its measurements are combined with other maintenance information.
7. Battery and DC System Testing
One major advantage of the TA813B+ over an AC-only clamp meter is DC current measurement.
This makes it relevant to applications such as:
Battery systems
DC power supplies
Industrial control systems
Automation
Inverter systems
Other suitable DC circuits
Before measuring DC current:
Select DC Current
↓
Keep Clamp Clear
↓
Perform DC Zero Adjustment
↓
Clamp Appropriate Individual Conductor
↓
Measure
Do not clamp positive and negative conductors together when the objective is to measure normal circuit current.
Their magnetic fields can oppose each other and produce a very low reading.
8. Solar and Inverter Troubleshooting
A simplified solar power path is:
PV Modules → DC Circuit → Inverter → AC Circuit → Load
This means technicians may encounter both:
DC
and
AC
within the same overall system.
An AC/DC clamp meter can therefore provide additional flexibility for general troubleshooting.
The TA813B+ can support suitable AC/DC electrical measurements within its specifications.
However, it does not replace specialized solar instruments required for tasks such as:
PV insulation testing
I-V curve testing
Irradiance measurement
Dedicated commissioning tests
Use instruments according to the actual solar test requirement.
9. Industrial Automation and DC Control Panels
Modern factory machinery frequently combines AC and DC systems.
For example:
AC Supply
↓
DC Power Supply
↓
PLC
↓
Sensors / Relays / Controllers
The maintenance technician may need to work on both sides of the system.
This is where an AC/DC clamp meter can provide greater flexibility than an AC-only model.
Possible measurements can include:
AC voltage
DC voltage
AC current
DC current
Frequency
Resistance
Continuity
The actual test method depends on the circuit and equipment.
10. Factory Preventive Maintenance
The TA813B+ can also become part of a preventive-maintenance program.
Instead of using the meter only after equipment fails:
Measure While Healthy
↓
Record Baseline
↓
Repeat Measurement
↓
Compare Trend
↓
Investigate Change
For example:
EquipmentCurrentFrequencyVibrationTemperaturePump 01RecordRecordRecordRecordCompressor 01RecordRecordRecordRecordAHU Fan 01RecordRecordRecordRecordProcess Motor 01RecordRecordRecordRecord
Historical data can provide more context than an isolated measurement.
Bonus Application: Ghost Voltage Investigation
Unexpected voltage can sometimes appear because of capacitive coupling or other circuit conditions.
The TA813B+ provides High / Low Impedance voltage measurement.
Low-Z can help technicians investigate suspected ghost or phantom voltage.
However:
Never assume unexpected voltage is harmless.
Unexpected voltage should be treated seriously until properly investigated using appropriate electrical-safety procedures.
Bonus Application: NCV Screening
The TA813B+ also provides NCV — Non-Contact Voltage detection.
This can be useful as a preliminary indication that AC voltage may be present.
However:
NCV ≠ Proof of Safe Isolation
NCV should not be used as the sole method for proving that a conductor or circuit is safe to touch.
Follow proper electrical verification procedures.
Why AC/DC Current Matters
Consider three technicians.
Technician A
Works mainly with conventional AC motors.
An AC clamp meter may cover many routine measurements.
Technician B
Works with:
Motors
VFDs
Pumps
HVAC
Functions such as True RMS, Inrush and VFD-related measurement become more relevant.
Technician C
Works with:
Motors
Batteries
DC power supplies
Automation
Inverters
Solar systems
An AC/DC clamp meter becomes considerably more flexible.
This is where the TA813B+ fits particularly well.
TASI TA813A+ vs TA813B+
Within the TA813 series, application should determine the choice.
Function / ApplicationTA813A+TA813B+AC CurrentYesYesTrue RMSYesYesInrush CurrentYesYesVFD VoltageYesYesAC/DC VoltageYesYesDC Current—YesDC Zero Adjustment—YesRelative Value—YesInductance—Yes
If the technician mainly needs AC current measurement, the TA813A+ may already cover the requirement.
If the work includes DC current and broader mixed AC/DC applications, the TA813B+ provides additional capability.
TA813B+ Is Not a Dedicated Leakage Current Clamp
Another important distinction:
General Clamp Meter ≠ Leakage Current Clamp
The TA813B+ is primarily positioned for general electrical current and troubleshooting applications.
If the requirement is to measure very small leakage or residual currents, select an instrument specifically designed with the necessary range, resolution and sensitivity.
Similarly:
Leakage Current Clamp
and
Insulation Resistance Tester
perform different tests.
Choose the instrument according to the actual measurement objective.
TA813B+ + Vibration Meter
For rotating equipment:
Clamp Meter
→ Electrical load
Vibration Meter
→ Mechanical vibration
This combination is particularly useful for:
Motors
Pumps
Compressors
Fans
Cooling towers
Production machinery
MTM Precision vibration meter options include:
Landtek VM6310
Landtek VM6360
Landtek VM6380
Wintact WT63A / WT63B
Benetech GM63B
Smart Sensor AR63B
TA813B+ + Thermal Camera
Add thermal inspection for:
Electrical panels
Breakers
Terminals
Contactors
VFD cabinets
Motors
Bearings
Now the maintenance team can compare:
Current
Vibration
Temperature
This provides much better context than one measurement alone.
TA813B+ + Tachometer
A tachometer adds:
Rotational Speed
This is especially useful for VFD-controlled:
Pumps
Fans
Motors
Process equipment
A useful condition-monitoring record can therefore contain:
Current + Frequency + Speed + Vibration + Temperature
Who Should Consider the TASI TA813B+?
The TA813B+ is particularly relevant to:
Electricians
Factory maintenance technicians
Facility maintenance teams
HVAC technicians
Motor service technicians
Pump maintenance technicians
Automation technicians
Electrical contractors
M&E contractors
Industrial service companies
It is especially useful where technicians encounter a combination of AC and DC electrical systems.
A Practical Factory Toolkit
Instead of looking for one instrument that does everything, build a toolkit according to the problem.
TASI TA813B+ Clamp Meter
→ Electrical current / voltage / frequency
Vibration Meter
→ Mechanical condition
Thermal Camera
→ Temperature patterns
Tachometer
→ Speed
Insulation Resistance Tester
→ Insulation resistance
Leakage Current Clamp
→ Small residual / leakage current
Different instruments answer different questions.
Important Electrical Safety
The TA813B+ is specified for CAT III 1000V applications according to the manufacturer's series information, but the instrument's rating does not replace safe working procedures.
Before measurement, always verify:
Correct measurement mode
Instrument condition
Jaw condition
Test lead condition
Voltage/current limits
Measurement category
PPE requirements
Site procedures
Equipment manufacturer instructions
Measurements on energized industrial systems should only be performed by appropriately trained personnel.
VFD, battery and solar systems can also contain hazardous stored energy even when certain equipment has been switched off.
TASI TA813B+ True RMS AC/DC Clamp Meter Malaysia
The TASI TA813B+ True RMS Digital Clamp Meter can support a wide range of electrical and industrial maintenance applications including:
Motor
Pump
VFD
HVAC
Air Compressor
Battery
DC Power Supply
Solar / Inverter
Automation
Factory Preventive Maintenance
For customers who are not sure whether they need the TA813A+ or TA813B+, MTM Precision can help compare the required functions according to the actual application.
MTM Precision Sdn Bhd
Showroom & Service Centre
No 29-1 & 2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Supporting electrical, factory, HVAC and industrial maintenance customers throughout Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.
27 Sep 2026