Combustible gas leaks often begin at small points such as pipe joints, valves, fittings, connectors and equipment connections.
The leak may not always be obvious during a normal visual inspection. For maintenance technicians, a portable combustible gas detector such as the TASI TA702A or TA702B can help screen an area and trace a suspected leak source.
Where Should You Check for Gas Leaks?
When inspecting a gas piping system, technicians can pay particular attention to locations such as:
Pipe joints
Valves
Flanges
Regulators
Flexible hose connections
Gas fittings
Equipment connections
Areas where previous maintenance was performed
These are common points where leakage may need to be investigated.
Start by Screening the Surrounding Area
Do not immediately place the detector at only one suspected point.
A practical approach is to begin by checking the surrounding area and then gradually move the probe toward individual joints, valves and fittings.
This can help identify where the detector response becomes stronger.
The TASI TA702 Series uses a flexible probe, making it easier to inspect around equipment and locations that may be difficult to reach directly.
Using TA702A for Leak Locating
The TASI TA702A is particularly useful for technicians whose main objective is to locate a suspected combustible gas leak.
One useful feature is its:
High / Medium / Low sensitivity adjustment
A technician can start with higher sensitivity when searching a wider area.
As the detector responds and the suspected area becomes smaller, the sensitivity can be adjusted to help narrow down the possible source.
This makes TA702A suitable for practical troubleshooting around:
Pipe → Joint → Valve → Connection → Suspected Leak Point
Instead of checking an entire installation manually, the detector helps the technician concentrate on areas producing a stronger response.
When Is TA702B More Suitable?
The TASI TA702B is useful when the technician wants additional information during the inspection.
TA702B provides ppm / LEL indication, together with ambient temperature and concentration trend information.
This can be useful when comparing detector responses at different inspection points.
For example:
Point A – Pipe connection
Point B – Valve
Point C – Regulator
Point D – Equipment connection
If the detector response increases when approaching a particular area, the technician can investigate that location more closely.
Flexible Probe Helps Reach Difficult Areas
Gas pipe installations are not always easily accessible.
Connections may be located:
Behind machinery
Below equipment
Inside cabinets
Between pipes
Near walls
Around valves
In poorly illuminated areas
The TA702 Series combines a flexible extension probe and LED illumination, helping the operator position the sensing area closer to difficult inspection points.
This is especially practical for maintenance technicians working around machinery and building services.
Applications in Malaysia
Portable combustible gas leak detection can be relevant to many maintenance environments in Malaysia, including:
Factory Maintenance
Technicians can inspect applicable gas piping, valves and equipment connections during troubleshooting or preventive maintenance.
Hotel & Restaurant Maintenance
Gas-related installations around commercial kitchens may require periodic inspection according to the facility's maintenance and safety procedures.
Building & Facility Management
Facility teams can use portable leak detection equipment when investigating suspected combustible gas leakage around relevant installations.
Industrial Maintenance
Maintenance contractors can carry a portable detector for troubleshooting gas piping and connected equipment where the instrument is suitable for the application.
TA702A or TA702B for Pipe Leak Detection?
The choice depends on what the technician needs.
TA702A
Suitable when the main objective is straightforward leak searching and locating, with three sensitivity levels helping to narrow down the suspected source.
TA702B
Suitable when the operator also wants ppm/LEL indication and additional concentration information during inspection.
For many maintenance applications, the question is not simply which model is more advanced.
The better question is:
Do you only need to locate the leak, or do you also need additional concentration indication?
Important Safety Consideration
A handheld combustible gas leak detector should be used according to the manufacturer's instructions and the applicable workplace safety procedure.
Do not rely on a portable leak detector as the only safety measure in a potentially hazardous atmosphere.
Applications involving confined-space entry, personal exposure monitoring, continuous area monitoring or safety-critical atmospheric testing may require appropriately specified and certified gas monitoring equipment.
Looking for a Combustible Gas Leak Detector in Malaysia?
MTM Precision supplies portable testing and measuring instruments for maintenance, industrial inspection, facility management and troubleshooting applications.
For TASI TA702A / TA702B selection, tell us:
1. What gas do you need to detect?
2. Where will you use the detector?
3. Do you need leak locating only or ppm/LEL indication?
We can help you compare the suitable model for your application.
MTM Precision Sdn Bhd
Showroom & Service Centre
No 29-1 & 2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor.
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Serving customers throughout Malaysia, Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.
27 Sep 2026