How to Check Fiber After Fusion Splicing with NOYAFA NF-9816 OTDR Malaysia
How to Check Fiber After Fusion Splicing with NOYAFA NF-9816 OTDR Malaysia
Completing a fusion splice does not automatically mean the fiber link is ready for service.
The fusion splicer may indicate that the splice has been completed successfully, but technicians may still need to verify the installed fiber link using appropriate test equipment.
The NOYAFA NF-9816 Multi-Function OTDR Pro can help technicians locate splice events, evaluate the fiber route and investigate abnormal loss after fiber fusion splicing.
For FTTH, CCTV, factory, building and data centre fiber projects in Malaysia, a useful workflow is:
Splice → Protect → Test → Verify → Document
Why Test After Fusion Splicing?
Fusion splicing joins two optical fibers together.
A good splice should introduce minimal additional loss, but problems can still occur because of:
-
Poor fiber preparation
-
Contaminated fiber
-
Incorrect cleaving
-
Fiber alignment issues
-
Mechanical stress
-
Fiber bending after splicing
-
Incorrect splice tray arrangement
Testing helps verify the condition of the completed link.
Fusion Splicer Estimate vs OTDR Measurement
A fusion splicer may display an estimated splice-loss value.
This is useful during the splicing process.
However, this estimate is not the same as independently testing the installed fiber link.
An OTDR measures the optical characteristics of the fiber route and can help identify events at different distances.
For important projects, technicians should follow the required project acceptance procedure rather than relying only on the splice machine's estimated result.
Step 1: Confirm the Fiber Core
Before testing, confirm which fiber has been spliced.
Record:
-
Cable identification
-
Fiber/core number
-
Origin
-
Destination
-
Splice enclosure
-
Splice number
Correct identification becomes especially important when working with multi-core fiber cables.
Step 2: Inspect and Clean Test Connections
Before connecting the OTDR, ensure the test connection is clean.
Contaminated connectors can introduce additional loss and reflection.
Use a proper workflow:
Inspect → Clean → Connect → Test
Do not confuse a dirty test connection with a poor fusion splice.
Step 3: Run Automatic OTDR
The NF-9816 provides Automatic OTDR mode.
This can provide a convenient initial overview of the fiber.
Technicians can review:
-
Fiber length
-
Event locations
-
Fiber endpoint
-
Event Map
If the splice position is known, compare the expected distance with the detected event.
Example: Checking a New Splice
Suppose two fiber sections have been joined inside a splice enclosure approximately 850 metres from the test point.
After fusion splicing, the OTDR identifies an event around:
852 metres
The distance is consistent with the known splice enclosure.
The technician can then examine the event and determine whether further investigation is required.
Step 4: Use Event Map
The NF-9816 includes an Event Map function.
A simplified link might appear as:
0 m — Start
420 m — Event
850 m — Splice Area
1,370 m — Event
1,920 m — End
The Event Map can make it easier to associate detected events with actual network components.
Always compare the instrument result with installation documentation.
Step 5: Test at 1310nm and 1550nm
The NF-9816 supports OTDR testing at:
1310 nm
and
1550 nm
for G.652 single-mode fiber.
Its specified dynamic range is:
1310 nm — 26 dB
1550 nm — 28 dB
Testing at both wavelengths can provide additional information about the fiber link.
This can also help distinguish certain bend-related problems from other events.
What Does a Fusion Splice Look Like on an OTDR?
A normal fusion splice is generally associated with a non-reflective loss event.
This differs from strongly reflective events that may be associated with certain connectors, mechanical interfaces or open fiber ends.
However, OTDR interpretation should consider:
-
Fiber characteristics
-
Test direction
-
Pulse width
-
Measurement conditions
-
Event spacing
Do not judge an entire fiber link from one number alone.
What Is a High Splice Loss?
There is no single universal splice-loss pass/fail limit that should be applied to every project.
Acceptance criteria may depend on:
-
Project specification
-
Customer requirements
-
Network design
-
Applicable standards
-
Fiber type
-
Testing procedure
Always compare the measurement against the requirements of the actual project.
Why Does OTDR Sometimes Show Negative Splice Loss?
Technicians may occasionally see a splice event that appears to have negative loss.
This is sometimes called a gainer.
It does not mean the splice is generating optical power.
Different backscatter characteristics between the two fiber sections can affect one-direction OTDR measurements.
This is one reason why splice-loss analysis may require measurements from both directions.
Bidirectional OTDR Testing
For more accurate splice-loss assessment, technicians may perform OTDR measurements from both ends when required by the testing procedure.
For example:
Building A → Building B
and
Building B → Building A
The two measurements can then be evaluated according to the required method.
This can reduce the influence of backscatter differences between fiber sections.
Example: Splice Looks Good from One Direction
A technician tests a newly completed splice from Building A.
The OTDR result appears unusually low.
Instead of immediately concluding that the splice is excellent, the technician tests from Building B.
The reverse-direction measurement gives a different result.
This does not necessarily mean the instrument is faulty.
Backscatter differences can influence one-direction splice measurements.
Proper bidirectional evaluation provides a better basis for assessment when required.
Step 6: Use Expert OTDR for Detailed Analysis
Automatic OTDR is useful for initial testing.
If the splice requires closer examination, the NF-9816 also provides Expert OTDR functionality.
Experienced technicians can adjust measurement parameters according to the fiber link and test objective.
This can be useful when:
-
Splices are close together
-
Events are difficult to separate
-
Fiber distance is unusual
-
Automatic results require further analysis
Pulse Width Matters
Pulse width affects OTDR performance.
Shorter pulses can help improve the ability to distinguish closely spaced events.
Longer pulses can provide more energy for longer-distance testing but may reduce the ability to separate nearby events.
Therefore, the correct setting depends on the fiber being tested.
Do Not Immediately Re-Splice Every Suspicious Event
If an OTDR indicates unusual loss near a splice location, investigate systematically.
Possible causes may include:
-
Poor fusion splice
-
Fiber bend inside the splice tray
-
Dirty connector elsewhere
-
Mechanical stress
-
Incorrect fiber routing
-
Nearby event affecting interpretation
Confirm the physical location before opening the splice enclosure.
Check Fiber Routing Inside the Splice Tray
A good fusion splice can still be followed by a fiber routing problem.
After splicing, fiber is normally arranged inside a splice tray.
If the fiber is bent too tightly or mechanically stressed, additional loss may occur.
This is why testing should be performed after the fiber has been properly arranged and protected.
Check the Fiber After Closing the Enclosure
Where practical, technicians may also verify the fiber after the splice enclosure has been properly assembled.
This helps confirm that final cable management has not introduced a new problem.
A fiber that tests well before final arrangement should still perform correctly after the job is completed.
Use Optical Power Measurement When Required
The NF-9816 also incorporates an Optical Power Meter (OPM) with a specified range of:
-50 dBm to +26 dBm
OTDR and optical power testing answer different questions.
OTDR: Where are events located?
OPM: What optical power is being measured?
Depending on the project, both measurements may be useful during commissioning.
Repair and Retest
If a splice does not meet the required acceptance criteria, corrective work may be necessary.
After re-splicing:
Run the OTDR test again.
Compare:
Before Repair
with
After Repair
Confirm that the suspicious event has improved.
Do not stop after physically completing the new splice.
Save the Final OTDR Trace
After the fiber passes the required test procedure, save or document the final result where applicable.
Useful information includes:
-
Fiber/core number
-
Origin and destination
-
Fiber length
-
Test wavelength
-
Splice locations
-
OTDR trace
-
Event Map
-
Test direction
-
Test date
-
Technician
These records can become the baseline for future maintenance.
Example: Factory Fiber Extension
A factory adds a new warehouse.
An existing fiber route is extended by fusion splicing a new cable section.
After splicing, OTDR testing identifies the new splice location.
The technician verifies the route and records the final trace.
Two years later, if the link develops a problem, maintenance teams can compare the new result with the original post-splicing baseline.
Example: CCTV Fiber Repair
An underground CCTV fiber is damaged during construction work.
The damaged section is repaired using fusion splicing.
After the repair:
1. Test from the control-room side
2. Confirm the repaired section
3. Test from the opposite side if required
4. Check optical performance
5. Confirm CCTV communication
6. Save the final result
The repair is not complete until the fiber link has been verified.
Example: FTTH Fiber Splicing
During FTTH installation, technicians may perform multiple fiber splices.
Testing can help confirm:
-
Fiber continuity
-
Correct endpoint
-
Unexpected events
-
Fiber distance
-
Splice condition
The exact acceptance method should follow the network operator or project requirements.
Fusion Splicer and OTDR Have Different Jobs
A fusion splicer and OTDR should not be viewed as competing instruments.
They perform different tasks.
Fusion Splicer
Joins optical fibers.
OTDR
Tests and analyzes the fiber link.
For installation and repair work, they can form part of the same workflow:
Locate Fault → Prepare Fiber → Fusion Splice → Protect Fiber → OTDR Test → Verify → Document
NOYAFA NF-9816 for Fiber Splicing Verification Malaysia
Looking for an OTDR for fusion splice checking, fiber installation, fiber repair, FTTH, CCTV, factory or data centre fiber testing in Malaysia?
Contact MTM Precision Sdn Bhd for enquiries about the NOYAFA NF-9816 and other fiber optic testing instruments.
MTM Precision Sdn Bhd
Showroom & Service Centre:
No 29-1 & 2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Enquiries are welcome from Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Perlis, Kelantan, Terengganu, Sabah and Sarawak.
27 Sep 2026