How to Find Which Fiber Core Has a Problem with NOYAFA NF-9816 Malaysia

How to Find Which Fiber Core Has a Problem with NOYAFA NF-9816 Malaysia

A multi-core fiber cable may contain several individual optical fibers inside the same cable.

When a network problem occurs, the entire cable does not necessarily need to be damaged.

Sometimes only one or several fiber cores have a problem while the remaining cores continue operating normally.

The NOYAFA NF-9816 Multi-Function OTDR Pro can support technicians when checking multi-core fiber installations and identifying which fiber requires further investigation.

This is useful for fiber networks in:

  • Factories

  • CCTV systems

  • Commercial buildings

  • Data centres

  • Industrial sites

  • Campus networks

  • Building-to-building connections

What Is Multi-Core Fiber?

In practical field terminology, a multi-core fiber cable contains multiple individual fiber strands within one cable construction.

For example, a cable may contain:

4 cores

6 cores

12 cores

24 cores

or more, depending on the installation.

Different cores may be assigned to different services.

One fiber cable could support:

  • CCTV

  • Building network

  • Access control

  • Industrial communication

  • Spare fiber

  • Future expansion

This makes correct fiber identification important.

One Cable Does Not Mean One Fiber Result

Suppose a 12-core fiber cable connects two factory buildings.

Core 1 and Core 2 are used for the production network.

Core 3 and Core 4 support CCTV.

The remaining cores are reserved as spares.

If CCTV communication fails but the production network remains operational, it does not automatically mean the complete fiber cable is healthy or faulty.

The affected CCTV cores should be tested individually.

First Identify the Affected Service

Before connecting an OTDR, understand what has stopped working.

Ask:

  • Which equipment is offline?

  • Which building is affected?

  • Which switch uses the fiber?

  • Which fiber core is assigned to that service?

  • Are other services on the same cable still operating?

Good troubleshooting begins with network information.

Check the Fiber Schedule

A properly documented fiber installation should have a fiber schedule.

For example:

Core 1 — Building A to Building B Network

Core 2 — Building B to Building A Network

Core 3 — CCTV TX

Core 4 — CCTV RX

Core 5–12 — Spare

The actual arrangement depends on the network design.

The important point is to know which core should be tested.

What If the Fiber Is Poorly Labelled?

This is common in older installations.

Technicians may open a fiber distribution box and find incomplete or outdated labeling.

Do not randomly disconnect production fibers.

First review:

  • Old drawings

  • Patch panel labels

  • Switch connections

  • Splice records

  • Previous maintenance records

Fiber identification should be performed carefully, especially on live networks.

NOYAFA NF-9816 Multi-Core Test

The NF-9816 includes a Multi-Core Test function designed to support work involving multiple fiber cores.

This can help improve workflow when technicians need to test several fibers rather than repeatedly treating every core as an unrelated job.

It can be particularly useful during:

  • New installation

  • Commissioning

  • Fiber acceptance

  • Maintenance

  • Troubleshooting

  • Multi-core cable verification

Test Each Relevant Core

For a multi-core cable, technicians may need to test each required fiber core and record the result.

A simple record might look like:

Core 1 — Normal

Core 2 — Normal

Core 3 — Abnormal event at 680 m

Core 4 — Normal

Core 5 — Spare / Tested

Core 6 — Spare / Tested

This immediately narrows the investigation.

Instead of saying:

“The fiber cable has a problem.”

the technician can report:

“Core 3 shows an abnormal event approximately 680 metres from the test point.”

That is much more useful.

Use OTDR to Locate the Problem

The NF-9816 supports OTDR testing at:

1310 nm

and

1550 nm

for G.652 single-mode fiber.

Its specified dynamic range is:

1310 nm — 26 dB

1550 nm — 28 dB

OTDR testing can help determine:

  • Fiber length

  • Event locations

  • Unexpected loss

  • Fiber endpoint

  • Possible break location

This information can then be compared with the physical fiber route.

Example: One CCTV Fiber Core Fails

A factory has a 12-core fiber cable running approximately 1.5 km between the main security room and a warehouse.

The production network continues operating.

However, the warehouse CCTV system goes offline.

The technician identifies the fiber cores assigned to CCTV and tests them.

One core reaches approximately:

1.5 km

The other unexpectedly ends at:

870 m

This provides a strong clue that one CCTV fiber core may have been damaged while other fibers inside the same cable remain operational.

How Can Only One Fiber Core Be Damaged?

A cable can experience different types of damage.

Depending on the incident, not every fiber inside the cable will necessarily fail in exactly the same way.

Possible situations include:

  • Localized mechanical stress

  • Fiber bending

  • Poor individual splice

  • Individual fiber handling damage

  • Termination problem

  • Damage inside a splice enclosure

Therefore, do not assume that all cores must show the same result.

Compare Multiple Cores

Other fiber cores in the same cable can sometimes provide useful reference information.

Suppose:

Core 1 — 1,820 m

Core 2 — 1,818 m

Core 3 — 1,821 m

Core 4 — 1,050 m

If all four cores should reach the same destination, Core 4 clearly deserves investigation.

Comparing multiple cores can make abnormal results easier to recognize.

Compare Event Positions Across Cores

Suppose several fiber cores show unusual events at approximately the same distance.

For example:

Core 1 — High loss around 930 m

Core 2 — High loss around 935 m

Core 3 — High loss around 932 m

This pattern may suggest that technicians should investigate a common physical location around that section of the route.

Possible areas include:

  • Splice enclosure

  • Manhole

  • Cable tray

  • Building entry point

  • Damaged cable section

OTDR does not prove the physical cause, but the distance pattern provides a valuable clue.

One Core Abnormal at a Splice Enclosure

Now consider another situation.

Only Core 7 shows abnormal loss around 620 metres.

The other cores are normal.

The fiber drawing shows a splice enclosure near the corresponding route section.

This may suggest an individual splice or fiber-routing problem rather than damage to the entire cable.

Technicians can inspect that location first.

Use Event Map

The NF-9816 includes an Event Map function.

For technicians checking multiple cores, Event Map can make it easier to compare significant events.

For example:

Core 1

0 m → 510 m → 1,020 m → 1,520 m End

Core 2

0 m → 510 m → 1,020 m → 1,520 m End

Core 3

0 m → 510 m → 790 m End

Core 3 clearly behaves differently.

Test at 1310nm and 1550nm

Testing at both supported OTDR wavelengths can provide additional diagnostic information.

This is especially useful when investigating possible bending-related loss.

If one core behaves differently from the others, compare the measurements carefully and perform physical inspection where appropriate.

Check the Splice Tray

Multi-core cables often contain many fusion splices inside the same enclosure.

During installation or repair, one individual fiber may be:

  • Poorly spliced

  • Bent too tightly

  • Incorrectly routed

  • Mechanically stressed

The other cores may remain normal.

If OTDR distance corresponds with a known splice enclosure, inspect the affected core carefully.

Check Spare Fiber Cores

Spare cores can be valuable.

During installation or maintenance, testing spare cores can confirm whether they are available for future use.

A spare fiber should not simply be assumed to be good because it has never been used.

Testing and documenting spare cores can help avoid surprises during future network expansion.

Can You Move the Service to a Spare Core?

In some installations, a healthy spare core may provide an alternative path while a damaged core is repaired.

However, this should only be done according to the network design and site procedures.

Technicians should confirm:

  • Correct fiber identification

  • Correct termination

  • Optical performance

  • Network configuration

  • Documentation updates

Do not move services randomly between unlabeled fibers.

Use OPM to Check Optical Power

The NF-9816 also incorporates an Optical Power Meter with a specified range of:

-50 dBm to +26 dBm

Optical power measurement can complement OTDR testing.

For example:

Core A — Expected optical power

Core B — Significantly lower optical power

The next step may be OTDR testing to investigate where additional loss is occurring.

Remember:

OPM tells you how much optical power is present.

OTDR helps identify where events are located.

Use VFL for Accessible Fiber Identification

The NF-9816 incorporates a 650 nm Visual Fault Locator (VFL) with a specified output of approximately 10 mW.

For appropriate accessible fiber sections, VFL can assist with:

  • Fiber identification

  • Continuity checking

  • Certain visible faults

This can be useful when technicians are working with several fibers and need to confirm the correct core.

Do Not Disconnect Live Fiber Without Planning

Multi-core cables may carry critical services.

One core could support CCTV while another supports:

  • Production systems

  • Access control

  • Building management

  • Network infrastructure

Before disconnecting or testing live fiber, follow site procedures and confirm which services may be affected.

Create a Core-by-Core Test Record

For important multi-core installations, maintain a structured record.

For example:

Cable: Factory A to Warehouse B
Cable Type: 12-Core Single-Mode
Core 1: Network — Tested
Core 2: Network — Tested
Core 3: CCTV — Tested
Core 4: CCTV — Tested
Core 5: Spare — Tested
Core 6: Spare — Tested

Include OTDR traces and test dates where required.

Multi-Core Fiber Commissioning

During a new installation, do not only test the active fibers.

Depending on the project requirement, it may be useful to verify all specified cores before handover.

This creates a baseline for:

  • Active fibers

  • Backup fibers

  • Spare fibers

When future expansion occurs, technicians already have information about the original cable condition.

Multi-Core Fiber Troubleshooting Workflow

A practical workflow is:

Identify Affected Service → Check Fiber Schedule → Identify Core → Clean Connection → Test Optical Power → OTDR Test → Compare Other Cores → Check Event Distance → Match Route → Inspect Physical Location → Repair → Retest → Update Records

This is much more efficient than treating the entire cable as one unknown problem.

NOYAFA NF-9816 for Multi-Core Fiber Testing Malaysia

Looking for an OTDR for multi-core fiber testing, fiber core fault location, factory networks, CCTV fiber, building backbone, data centre or fiber commissioning in Malaysia?

Contact MTM Precision Sdn Bhd for enquiries about the NOYAFA NF-9816 and other fiber optic testing instruments.

MTM Precision Sdn Bhd

Showroom & Service Centre:
No 29-1 & 2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.

Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my

Enquiries are welcome from Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Perlis, Kelantan, Terengganu, Sabah and Sarawak.

27 Sep 2026