UNI-T UT366A Digital Manometer Buying Guide for HVAC Technicians Malaysia
A digital manometer is used to measure low air or gas pressure in HVAC, ventilation and industrial systems. Before selecting an instrument, buyers should consider the required pressure range, measurement type, pressure units and whether airflow testing is needed.
The UNI-T UT366A is suitable for technicians who need a portable instrument for gauge pressure, differential pressure and optional duct air-velocity measurement.
What Can the UT366A Measure?
The UT366A can measure pressure through its two connection ports.
Its main measurement modes include:
-
Positive gauge pressure
-
Negative gauge pressure
-
Differential pressure
-
Independent P1 pressure
-
Independent P2 pressure
-
Air velocity with an optional Pitot tube
This allows one instrument to support several HVAC inspection tasks instead of being limited to a single application.
Check the Required Pressure Range
The UT366A has a pressure measurement range of ±15.00 kPa.
Equivalent selectable ranges include:
-
±150.0 mbar
-
±0.150 bar
-
±2.175 psi
-
±112.5 mmHg
-
±60.29 inH₂O
-
±1,531 mmH₂O
-
±150.0 hPa
The specified accuracy is ±0.5% full scale at 25°C.
Before purchasing, check the expected minimum and maximum pressure of the equipment. The instrument’s range should cover the application without being unnecessarily high for very small pressure changes.
Consider the Type of Measurement
Choose the UT366A when your work requires one or more of the following measurements.
AHU Filter Pressure Drop
Connect one hose before the filter and the other after the filter. The pressure difference helps technicians monitor increasing airflow resistance as the filter becomes loaded.
Duct Static Pressure
The instrument can be connected to an appropriate static-pressure test point to check pressure inside supply, return or exhaust ducts.
Fan Pressure Testing
P1 and P2 can be used to compare pressure at different points around a fan or ventilation component.
Room Differential Pressure
The UT366A can help compare pressure between two rooms or areas when suitable pressure connections are available.
Duct Air Velocity
With the optional Pitot tube, the UT366A can measure air velocity inside a duct in m/s or fpm.
Select the Correct Pressure Unit
Different HVAC specifications may use different units. The UT366A supports:
-
kPa
-
mbar
-
bar
-
psi
-
mmHg
-
inH₂O
-
inHg
-
oz/in²
-
kg/cm²
-
ftH₂O
-
mmH₂O
-
hPa
-
m/s and fpm with the airflow configuration
Its unit-memory function helps retain the selected unit for repeated work.
Do You Need the Optional Pitot Tube?
The standard UT366A package includes a pressure hose, but the Pitot tube is an optional accessory.
Add the Pitot tube when the intended work includes:
-
Internal duct air-velocity measurement
-
Airflow testing through a small duct access hole
-
HVAC testing and commissioning
-
Industrial ventilation assessment
-
Air-volume calculations based on average velocity and duct area
The compatible Pitot tube is made from 304 stainless steel and measures approximately 350 mm long with an 8 mm diameter.
If the main requirement is only filter pressure drop or duct pressure, the Pitot tube may not be necessary.
UT366A or a Standard Anemometer?
The UT366A is the better choice when pressure measurement is important.
Choose the UT366A for:
-
Filter pressure drop
-
Differential pressure
-
Static duct pressure
-
Positive and negative pressure
-
Air velocity inside a duct with a Pitot tube
Choose a vane or hot-wire anemometer when the main requirement is:
-
Quick airflow checks at grilles
-
Open-outlet measurements
-
Direct fan airflow testing
-
Simple environmental air-velocity measurement
Some HVAC technicians use both instruments because they are designed for different measurement points.
Useful Functions for Field Work
The UT366A includes several functions that support inspection work:
-
MAX for the highest recorded value
-
MIN for the lowest recorded value
-
AVG for average measurement
-
HOLD for retaining a displayed reading
-
White display backlight
-
Automatic power-off
-
Low-battery indication
-
Positive and negative pressure LED indicators
-
Magnetic hook for convenient positioning
The instrument is powered by three AAA batteries and has a compact body for carrying between service locations.
Important Questions Before Ordering
Before buying the UT366A, confirm:
-
What pressure range must be measured?
-
Is gauge pressure or differential pressure required?
-
Which pressure unit is used in the equipment specification?
-
Will the instrument be used inside ducts?
-
Is a Pitot tube required?
-
Is the main task pressure testing or grille airflow testing?
-
Does the application require a calibration certificate?
Providing this information helps the supplier recommend the correct configuration.
Who Should Choose the UT366A?
The UNI-T UT366A is suitable for:
-
HVAC service technicians
-
Air-conditioning contractors
-
Facility-management teams
-
Testing and commissioning contractors
-
Factory maintenance departments
-
Cleanroom technicians
-
Data-centre maintenance teams
-
Industrial ventilation specialists
It can support maintenance work in factories, commercial buildings, hospitals, laboratories and data centres across Malaysia.
Get the Correct UT366A Configuration
For assistance selecting the UNI-T UT366A Digital Manometer, WhatsApp MTM Precision with your expected pressure range, measurement location and whether duct air-velocity testing is required.
MTM Precision Sdn Bhd
Showroom & Service Centre:
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
30 Sep 2026