UNI-T UT343E Coating Thickness Gauge Unstable or Inaccurate Readings Malaysia

UNI-T UT343E Coating Thickness Gauge Unstable or Inaccurate Readings Malaysia Content Published: 1 October 2026 If a UNI-T UT343E Coating Thickness Gauge produces unstable, unusually high or inconsistent readings, the problem may not necessarily indicate an instrument fault. Surface condition, substrate selection, probe position, component shape and reference checking can all affect the measurement. Perform several basic checks before deciding that the gauge requires inspection or calibration. Common UT343E Reading Problems Users may experience: Readings changing significantly at the same location Results that appear too high or too low Different results on similar components Incorrect ferrous or non-ferrous substrate identification No reading when the probe touches the surface Unstable readings near edges or corners Measurements that differ from another coating thickness gauge Readings outside the expected coating specification Record the substrate, coating type and measurement location before troubleshooting. Clean the Probe and Test Surface Dust, oil, moisture, metal particles or coating residue can prevent the probe from contacting the surface correctly. Before measuring: Wipe the test surface with a clean, soft cloth. Inspect the probe tip for contamination. Remove loose particles carefully. Ensure the surface is dry. Repeat the measurement at the same location. Do not use abrasive materials that may damage the probe or the coated surface. Check the Gauge with the Reference Plates The UT343E is supplied with ferrous and non-ferrous reference plates and standard coating films. Use these accessories to perform a basic operational check: Select the appropriate reference plate. Measure the uncoated plate. Place a known coating film on the plate. Measure the film several times. Compare the displayed result with the film value. A reference check confirms whether the instrument responds reasonably under controlled conditions. It is not the same as an accredited calibration. Confirm the Correct Substrate The UT343E measures coatings on: Ferrous metal: Steel, iron and other magnetic substrates Non-ferrous metal: Aluminium, copper, zinc and other non-magnetic substrates Incorrect substrate identification can cause unsuitable or inconsistent results. If automatic identification appears unstable, select the appropriate substrate mode manually and repeat the test. The instrument cannot measure coatings properly on plastic, wood, glass, rubber or composite surfaces without a compatible metal substrate. Keep the Probe Perpendicular The probe should be placed flat and perpendicular to the test surface. Tilting the instrument or touching the surface only with the edge of the probe may cause inconsistent results. Use a steady movement: Lower the probe vertically Allow the reading to complete Lift the probe away from the surface Reposition it for the next measurement Do not drag the probe across the coating. Avoid Edges, Corners and Curved Surfaces Measurements taken too close to an edge, corner, hole or strongly curved area may differ from readings on a flat central surface. When possible: Measure on a flat area Move away from edges and openings Use the same position for comparison Take several nearby readings Compare similar areas on equivalent components If the part is small or highly curved, confirm that its geometry is suitable for the probe. Check Whether the Coating Is Uneven The gauge may be working correctly even when readings vary. Actual coating thickness can change because of: Uneven spray application Multiple paint layers Repaired automotive panels Excess powder around corners Thin coating at edges Surface roughness Previous polishing or grinding Different production batches Measure several points and review the minimum, maximum and average values before deciding that the instrument is inaccurate. Compare Instruments Carefully Two coating thickness gauges may not display identical readings if they use different: Accuracy specifications Probe designs Reference settings Substrate modes Measurement positions Calibration conditions To make a meaningful comparison, use the same reference plate, coating film, substrate mode and measurement location. A small difference within the instruments’ stated accuracy does not automatically indicate a fault. Restart and Recheck the UT343E If the display or measurement response appears abnormal: Switch off the instrument. Check that the battery has sufficient charge. Restart the UT343E. Clean the probe and reference plate. Repeat the reference check. Test both ferrous and non-ferrous plates separately. Do not open the instrument or attempt to adjust the probe internally. Checking, Calibration and Repair Are Different A functional check uses reference plates and coating films to confirm that the gauge responds normally. A calibration compares the instrument’s results against traceable reference standards and records the measurement error under controlled conditions. A repair is required only when inspection identifies a defective probe, damaged electronics, unstable connection or another hardware problem. If the instrument fails repeated reference checks, professional inspection may be necessary before calibration. When Should the UT343E Be Inspected? Arrange further inspection if: The instrument repeatedly fails its reference check Readings remain unstable on clean, flat reference plates The probe does not detect ferrous or non-ferrous substrates Results are consistently outside the expected tolerance The probe has been dropped or physically damaged The display shows an error or does not respond The instrument was exposed to water, chemicals or severe impact Reliable results cannot be obtained after restarting Avoid using questionable readings for product acceptance or rejection until the gauge has been checked. UT343E Support in Malaysia Factories, automotive workshops and coating inspectors in Selangor, Kuala Lumpur, Johor and Penang can contact MTM Precision for assistance with coating thickness gauge selection and initial troubleshooting. WhatsApp a clear photo of the UNI-T UT343E, its model label, reference-check result and visible symptom for an initial assessment. MTM Precision Sdn Bhd Showroom & Service Centre: No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia Tel: 03-8080 7172 WhatsApp: +6016-660 7346 Email: mtmpre@yahoo.com Website: www.mtmpre.com.my

01 Oct 2026