UNI-T UT343E for Zinc Chrome and Metal Plating Thickness Inspection Malaysia

UNI-T UT343E for Zinc Chrome and Metal Plating Thickness Inspection Malaysia

Content

Published: 1 October 2026

The UNI-T UT343E Coating Thickness Gauge can support non-destructive thickness inspection of suitable conductive coatings, including zinc, chromium and tin, on compatible metal substrates.

It provides a 0–2000μm range, automatic or manual substrate identification, Bluetooth data transfer and storage for up to 3300 readings. These functions are useful for metal-finishing factories, incoming quality control and plated-component inspection in Malaysia.

Why Measure Metal Plating Thickness?

A metal coating may be applied to improve:

  • Corrosion resistance
  • Surface durability
  • Electrical performance
  • Appearance
  • Wear resistance
  • Product service life

If the coating is too thin, the component may not receive the intended protection. Excessive coating can increase processing cost or affect component dimensions and fit.

Thickness inspection helps manufacturers compare production results with the approved product specification.

Suitable Coating and Substrate Combination

A coating thickness gauge works according to the physical properties of both the coating and the base metal.

Before selecting the UT343E, identify:

  1. The coating material
  2. The substrate material
  3. The expected thickness
  4. The component shape and size
  5. The required accuracy
  6. Whether inspection records are required

Do not choose a gauge based only on the name of the coating. For example, a zinc coating on steel and a coating on aluminium may require different measurement principles.

The actual coating-and-substrate combination should be confirmed before purchase.

Ferrous and Non-Ferrous Substrate Detection

The UT343E supports measurements on:

  • Ferrous substrates: Steel, iron and other magnetic metals
  • Non-ferrous substrates: Aluminium, copper, zinc and other non-magnetic metals

The instrument can identify the substrate automatically or allow the operator to select the required mode manually.

Manual selection can be useful when repeatedly inspecting the same type of component.

Applications for Zinc-Coated Components

Zinc coatings are commonly used to protect steel components against corrosion.

Potential inspection applications include:

  • Plated fasteners
  • Steel brackets
  • Automotive components
  • Fabricated metal parts
  • Electrical hardware
  • Machinery components
  • Construction fittings
  • Outdoor metal products

The operator should measure several points because plating thickness may vary across edges, recesses, threads and complex shapes.

Very small fasteners or narrow curved surfaces may not provide enough flat area for reliable probe contact.

Applications for Chromium and Tin Coatings

Chromium and tin coatings are used in different manufacturing and finishing processes.

Possible applications include:

  • Decorative metal components
  • Machinery parts
  • Automotive fittings
  • Electrical components
  • Plated production samples
  • Incoming plated materials
  • Surface-treatment quality control

Compatibility depends on the coating, substrate and thickness range. A reference sample with a known coating thickness is recommended when evaluating the instrument for a specific plating process.

0–2000μm Measuring Range

The UT343E provides:

  • Measuring range: 0–2000μm
  • Resolution: 0.1μm from 0–99.9μm
  • Resolution: 1μm from 100–2000μm
  • Accuracy: ±(2%H + 2μm)
  • Units: μm and mil

The expected plating thickness must be compared with the instrument’s stated accuracy and resolution.

For extremely thin or highly specialised electroplating measurements, a different instrument or laboratory method may be required.

How to Check a Plated Component

Before starting an inspection:

  1. Confirm the coating and substrate materials.
  2. Clean the component and probe tip.
  3. Check the instrument using a suitable reference plate.
  4. Position the probe perpendicular to the surface.
  5. Take several readings at different locations.
  6. Review the minimum, maximum and average values.
  7. Compare the results with the approved specification.

Use the same measurement positions when comparing different production batches.

Inspect More Than One Location

Plating thickness may vary because of:

  • Component geometry
  • Current distribution during electroplating
  • Distance from the electrode
  • Edges and recessed areas
  • Surface preparation
  • Bath condition
  • Processing time
  • Part positioning

A single reading cannot represent the complete component.

The inspection plan should include flat areas, edges, recessed sections and other locations important to the product’s performance.

Bluetooth and Data Storage

The UT343E supports a mobile application through Bluetooth and can store up to 3300 readings.

These functions help quality-control teams:

  • Record results from multiple components
  • Compare different inspection points
  • Review maximum, minimum and average values
  • Organise readings by batch
  • Reduce manual data recording
  • Transfer results for further reporting

USB communication and PC software are also available for data analysis.

Set Upper and Lower Thickness Limits

The operator can set upper and lower measurement limits based on the approved plating specification.

The LED and audio alarm help indicate whether a reading is within the selected range.

This is useful for production sampling, but the limit values must come from the drawing, customer requirement, internal specification or approved reference sample.

The instrument does not determine the correct coating thickness automatically.

Important Measurement Limitations

The UT343E may not be suitable when:

  • The coating-and-substrate combination is incompatible
  • The component is too small for proper probe contact
  • The surface is strongly curved or rough
  • The coating is thinner than the practical capability required
  • The substrate is plastic, glass, wood or composite
  • A laboratory-certified measurement method is specified
  • The application requires elemental or material-composition analysis

For critical plating applications, verify the proposed measurement method against the applicable technical specification before relying on production readings.

Who Should Use the UT343E?

The UNI-T UT343E may be suitable for:

  • Electroplating factories
  • Metal-finishing companies
  • Automotive component manufacturers
  • Fastener suppliers
  • Incoming quality-control departments
  • Metal fabrication companies
  • Production inspection teams
  • Coating contractors

Manufacturers in Selangor, Kuala Lumpur, Johor and Penang can use it for suitable plated-component checks and digital measurement records.

For assistance evaluating the UT343E for zinc, chromium, tin or other coating applications, send MTM Precision the coating material, substrate material, expected thickness and component photo.