How to Use UNI-T LM320E for Pipe Slope and Drainage Installation Malaysia
How to Use UNI-T LM320E for Pipe Slope and Drainage Installation Malaysia
Content
Published: 4 October 2026
The UNI-T LM320E Digital Angle Meter can assist with checking pipe slope, drainage fall and supporting-bracket angles.
It can display the measured inclination in:
Degrees
Percentage
mm/m
in/ft
This allows Malaysian contractors to work with the unit stated in the project drawing or installation specification.
The LM320E also has two laser reference lines and magnetic mounting at the bottom and rear.
However, the instrument must sit securely on a suitable reference surface.
It may not provide a reliable result when placed directly on a small or strongly curved pipe.
Why Is Pipe Slope Important?
A pipe may require a specific slope to support:
Water flow
Waste discharge
Condensate drainage
Gravity-fed movement
Air release
System emptying
Maintenance drainage
Insufficient slope may contribute to:
Standing water
Slow drainage
Sediment buildup
Blockage
Backflow
Poor system performance
An excessive slope may also be unsuitable for certain systems.
The correct slope must come from the approved drawing, engineering specification or manufacturer’s installation instructions.
What Does Percentage Slope Mean?
Percentage slope describes the vertical rise or fall compared with the horizontal distance.
The basic relationship is:
Percentage slope = Vertical change ÷ Horizontal distance × 100
For example, a 2% slope means:
20 mm of fall over 1 metre
40 mm of fall over 2 metres
100 mm of fall over 5 metres
The LM320E can display the slope directly in percentage mode.
The installer must still confirm the intended direction of fall.
What Does mm/m Mean?
The mm/m unit describes the vertical change in millimetres over one metre of horizontal distance.
Examples include:
5 mm/m means 5 mm of fall over 1 metre
10 mm/m means 10 mm of fall over 1 metre
20 mm/m means 20 mm of fall over 1 metre
30 mm/m means 30 mm of fall over 1 metre
A value of 10 mm/m equals a 1% slope.
A value of 20 mm/m equals a 2% slope.
This unit can be convenient when pipe drawings or installation teams work with metric dimensions.
Degrees vs Percentage for Pipe Slope
Degrees and percentage are not the same.
For example:
1° is approximately 1.75%
2° is approximately 3.49%
3° is approximately 5.24%
An instruction requiring a 2% slope does not mean that the pipe should be installed at 2°.
A 2% slope is approximately 1.15°.
Using the wrong unit can create a substantial installation error over a long pipe run.
Always confirm the unit symbol on the LM320E display.
Can the LM320E Be Placed Directly on a Pipe?
The LM320E may be placed directly on a pipe only when it can sit securely and consistently.
Suitability depends on:
Pipe diameter
Surface curvature
Pipe material
Contact area
Surface condition
Instrument orientation
Magnetic attraction
Required accuracy
A large pipe may provide a more stable contact area than a small pipe.
Small-diameter pipes can cause the instrument to rock or shift.
A number on the display does not guarantee that the contact condition is suitable.
Why Are Small Pipes Difficult to Measure?
A small pipe provides a narrow, curved contact area.
This may cause:
Instrument rocking
Side-to-side movement
Incorrect orientation
Unstable readings
Poor repeatability
Changes from small positioning differences
The LM320E should be aligned with the direction of the pipe.
If it sits at an angle across the pipe, the displayed result may not represent the true longitudinal slope.
Using a Pipe Support as the Reference
When direct pipe contact is unsuitable, the slope may be checked from a suitable flat support or bracket.
Possible reference surfaces include:
A flat pipe saddle
A verified support bracket
A mounting rail
An approved reference plate
A suitable installation fixture
The support must accurately represent the intended pipe slope.
Do not assume that every bracket is parallel to the pipe.
Confirm the relationship between the support and pipe before accepting the result.
Using a Temporary Reference Plate
A suitable flat reference plate may help the LM320E sit more securely on a curved pipe.
The plate or fixture should:
Sit consistently on the pipe
Follow the pipe’s longitudinal direction
Prevent rocking
Provide a flat surface
Remain stable during measurement
Avoid damaging the pipe coating
The fixture itself must be verified.
An incorrectly positioned plate can produce a stable but incorrect reading.
Using the Magnetic Base
The LM320E has magnetic mounting surfaces at the bottom and rear.
The magnet may help on suitable ferrous-steel pipes or brackets.
Before using magnetic mounting:
Confirm that the pipe material attracts the magnet
Clean the pipe surface
Remove metal particles from the LM320E
Check the strength of attachment
Make sure the instrument cannot slide
Keep away from moving equipment
Magnetic mounting may be weak or ineffective on:
Plastic pipes
Copper pipes
Aluminium pipes
Some stainless-steel pipes
Heavily coated steel pipes
Insulated pipes
A different supporting method may be required for these materials.
How to Check Pipe Slope with the LM320E
A general checking procedure is:
Confirm the required slope and unit.
Identify the high and low points.
Clean the measurement surface.
Select a suitable pipe, support or reference-plate position.
Align the LM320E with the pipe direction.
Select percentage, mm/m or the required unit.
Allow the reading to stabilise.
Record the result and direction of fall.
Repeat at several positions.
Recheck after tightening the supports.
The actual work procedure should follow the project requirements and site-safety rules.
Why Must the Instrument Follow the Pipe Direction?
The LM320E should normally be aligned with the longitudinal direction of the pipe when checking its slope.
If the instrument is angled sideways, it may measure a combination of:
Pipe slope
Side tilt
Surface curvature
Instrument misalignment
Marking the pipe direction or using a guide can improve repeatability.
Use the same orientation for every measurement along the pipe run.
Checking the Direction of Fall
A correct numerical value is not enough.
The pipe must also fall in the required direction.
Before installation, identify:
The starting point
The discharge point
The high point
The low point
The intended flow direction
After adjustment, verify that the elevation reduces toward the correct destination.
A pipe sloping at 2% in the wrong direction is still incorrectly installed.
Using the Laser Lines
The two laser lines can provide a visible reference beyond the LM320E.
They may assist with:
Positioning the next pipe bracket
Extending the direction of a slope
Marking a support location
Comparing nearby installation points
Following an inclined reference
The laser lines do not independently measure the pipe slope.
The LM320E must first be positioned correctly and show the required angle.
Bright light, long distances and uneven target surfaces may reduce laser visibility.
Can the Laser Set Every Pipe Support?
The laser may assist with initial positioning, but each support should still be measured.
Individual supports may differ because of:
Wall unevenness
Fabrication tolerances
Mounting-hole movement
Bracket deformation
Fastener tightening
Incorrect shimming
Do not install every support based only on one projected line without confirming the final pipe position.
Checking a Long Pipe Run
A correct reading at one point does not prove that the entire pipe run has a consistent slope.
Long pipes may contain:
Local sagging
High points
Low points
Uneven support spacing
Joint movement
Pipe deflection
Different slopes between sections
Take measurements at several positions.
Also compare the total elevation difference between the beginning and end of the pipe run.
Long-distance elevation checking may require surveying or laser-levelling equipment.
Example: Checking a 2% Drainage Slope
Assume a drainage pipe requires a 2% fall.
The required change is:
20 mm over 1 metre
40 mm over 2 metres
60 mm over 3 metres
100 mm over 5 metres
The installer can select percentage mode and adjust the pipe toward 2%.
The final inspection should also confirm:
Correct fall direction
Stable support positions
No local high points
No pipe sagging
Correct total elevation difference
No movement after tightening
The LM320E reading should form part of the inspection, not the only check.
Example: Checking a Condensate Drain
A condensate drain may require continuous fall toward the discharge point.
Potential problems include:
A flat section
A local upward slope
Pipe sagging
Incorrect support height
Movement near a joint
Use the LM320E at several sections rather than checking only near the equipment.
Confirm the required slope from the equipment manufacturer or project specification.
Do not apply a general drainage slope without checking the system requirement.
Checking Pipe Brackets Before Pipe Installation
The LM320E can be used to compare pipe-support or bracket angles before the pipe is installed.
A possible method is:
Install the first approved bracket.
Confirm its angle.
Establish the reference.
Use the laser line for preliminary positioning.
Install the next bracket.
Measure each bracket individually.
Correct any difference.
Recheck after tightening.
The bracket angle alone does not establish the final pipe elevation.
Support height and spacing must also be correct.
Recheck After Tightening
Pipe position may change when:
Clamps are tightened
Brackets are secured
Pipe joints are connected
Insulation is added
Supports carry the full pipe weight
The system is filled
Take a final measurement after the installation reaches its normal supported condition.
If the pipe will carry liquid, consider whether its deflection changes when filled.
The engineering or installation team should determine the appropriate inspection condition.
Surface Coatings and Insulation
Paint, protective coatings and insulation can affect how the LM320E sits on a pipe.
Possible issues include:
Soft insulation compressing
Uneven coating buildup
Raised pipe labels
Welded seams
Damaged paint
Protective wrapping
Surface contamination
Do not press the instrument into soft insulation and assume the reading represents the pipe.
Where necessary, measure from an approved support or accessible reference surface.
Common Pipe-Slope Measurement Mistakes
Common mistakes include:
Confusing degrees with percentage
Placing the meter across the pipe
Measuring from a strongly curved surface
Ignoring the direction of fall
Using only one measurement point
Assuming every bracket matches the pipe slope
Failing to recheck after tightening
Measuring over a weld seam
Using an unstable temporary plate
Relying only on the laser line
Ignoring sagging between supports
Recording a number without its unit
A repeatable reading requires a stable position and clearly defined measurement method.
Why Can the Reading Change Along the Pipe?
Different readings along a pipe may indicate:
Changing slope
Pipe sagging
Uneven supports
Local deformation
Poor instrument contact
Surface curvature differences
Incorrect measurement direction
Joint movement
Repeat the measurements using the same orientation.
If the differences remain, inspect the pipe installation rather than averaging all results immediately.
When Is the LM320E Not Sufficient?
Another instrument or method may be required when:
The pipe is too small for stable contact
The permitted tolerance is very tight
Elevation must be transferred over a long distance
The pipe is inaccessible
The system requires surveying control
The installation is underground
The pipe is hidden by insulation
A certified inspection is required
The project specifies another measurement method
Possible alternatives include:
A line laser
A rotary laser
An automatic level
A total station
A digital level
A verified slope fixture
Specialised pipe-installation equipment
Instrument selection should follow the working distance and required accuracy.
Who Can Use the LM320E for Pipe Work?
The LM320E may be useful for:
Plumbing contractors
Mechanical contractors
HVAC installers
Drainage contractors
Factory maintenance teams
Pipe fabricators
Building-services contractors
Facility-management teams
Renovation contractors
Technical training centres
Contractors in Selangor, Kuala Lumpur, Johor and Penang should confirm the pipe diameter, required slope and measurement tolerance before selecting the LM320E.
For application advice, send MTM Precision a clear photo showing the pipe, diameter, required slope and available measurement surface.
MTM Precision Sdn Bhd
Showroom & Service Centre: No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
04 Oct 2026