How to Use Relative and Absolute Angle Modes on UNI-T LM320E Malaysia
How to Use Relative and Absolute Angle Modes on UNI-T LM320E Malaysia
Content
Published: 4 October 2026
The UNI-T LM320E Digital Angle Meter supports both absolute and relative angle measurement.
Absolute mode shows the instrument’s angle according to its normal reference.
Relative mode allows the user to set the current position as a temporary zero and measure the difference from that position.
These two modes are useful for different jobs.
Using the wrong mode can produce a reading that appears correct but does not answer the actual measurement requirement.
What Is Absolute Angle Measurement?
Absolute-angle mode shows the orientation of the LM320E according to its standard internal reference.
It is normally used when the customer wants to determine:
Whether a surface is horizontal
Whether a component is vertical
The actual angle of a bracket
The slope of a pipe
The inclination of a machine frame
Whether an installation matches a stated angle
The value can be displayed in:
Degrees
Percentage
mm/m
in/ft
The selected unit should match the drawing, specification or inspection procedure.
When Should You Use Absolute Mode?
Use absolute mode when:
A drawing states a required angle
A pipe must have a specific percentage slope
A machine base must be checked for level
A frame must be installed vertically
An inspection record needs the actual angle
The result must be compared with a numerical tolerance
For example, if a drawing requires a bracket angle of 30°, absolute mode should be used to check whether the bracket reaches the specified value.
What Is Relative Angle Measurement?
Relative mode allows the user to choose a current position and treat it as zero.
After the relative reference is set, the LM320E displays the difference between that reference and another position.
This is useful when the user wants to:
Compare two surfaces
Copy an existing angle
Match repeated components
Measure deviation from a selected reference
Work from a surface that is not horizontal
The relative result does not necessarily show the actual angle from the horizontal.
It shows the difference from the selected reference.
Simple Relative-Angle Example
Assume an existing bracket is installed at 25°.
The user wants to install another bracket at the same angle.
A possible method is:
Place the LM320E on the approved bracket.
Confirm that the instrument is stable.
Set the current position as the relative zero.
Move the meter to the new bracket.
Adjust the bracket until the relative reading approaches zero.
Tighten the bracket.
Recheck the result.
A relative reading near zero means that the two measured surfaces are at approximately the same angle.
It does not mean that both surfaces are horizontally level.
Why Relative Zero Does Not Mean Horizontal
This is one of the most important points when using relative mode.
If the LM320E is placed on a surface inclined at 20° and that position is set as zero, the display will show a relative value of zero.
The surface is still physically inclined at 20°.
The instrument is only showing that there is no difference from the selected reference.
Before accepting the measurement, confirm whether the requirement is:
Zero relative difference
Zero absolute angle
A specific absolute angle
These are not the same conditions.
Using Relative Mode to Copy an Existing Angle
Relative mode can help copy the angle of:
A fabricated bracket
An inclined shelf
A machine support
A steel frame
A pipe support
A cabinet panel
An existing structure
The original component must first be confirmed as the correct reference.
If the original angle is wrong, copying it will reproduce the same error.
How to Copy an Angle
A general procedure is:
Clean the original reference surface.
Place the LM320E in a repeatable direction.
Allow the reading to stabilise.
Confirm that the original component is approved.
Activate relative mode.
Move the meter to the new component.
Use the same measurement direction.
Adjust until the relative difference is acceptable.
Tighten the component.
Recheck in both relative and absolute modes if required.
The acceptance tolerance should come from the drawing or inspection procedure.
Using Relative Mode for Repeated Brackets
Relative mode is useful when several brackets must match one approved bracket.
Possible applications include:
Pipe supports
Cable-tray supports
Shelf brackets
Machine guards
Steel-frame members
Solar-panel supports
Fabricated mounting plates
A practical process is:
Select one approved master bracket
Mark its measurement point
Set it as the relative reference
Measure each new bracket at the same point
Maintain the same instrument direction
Record the deviation
Adjust each bracket
Recheck after tightening
Do not keep resetting zero on every new bracket.
Doing so can cause the reference to drift from one component to the next.
Use one confirmed reference whenever possible.
Using Relative Mode for Machinery Components
Maintenance teams may use relative mode to compare:
Two machine frames
Opposite support members
Parallel guards
Adjustable plates
Repeated mounting brackets
Inclined covers
The result can show whether one component differs from the selected reference.
However, relative mode does not measure:
Shaft offset
Coupling alignment
Pulley alignment
Machine-centre position
Soft foot
Distance between components
Specialised machinery-alignment tools may still be required.
Using Relative Mode for Pipe Installation
Relative mode may help compare the slope of several pipe sections or supports.
For example:
A correctly installed section can be used as the reference.
The LM320E can then be moved to the next section.
The relative result shows how much the new section differs from the reference.
Before using this method, confirm:
The original pipe section is correct
The instrument can sit securely
The measurement direction is consistent
The pipe diameter is suitable
The required slope direction is maintained
A zero relative difference does not prove that the overall pipe run has the correct elevation.
Long-distance elevation should be checked separately where necessary.
Using Relative Mode on a Non-Level Reference
Some installations must follow an existing inclined surface.
Examples include:
An inclined roof structure
A sloping machine frame
An existing ramp
A fabricated support
A drainage structure
A special architectural feature
Relative mode allows the existing surface to become the working reference.
The user can then compare new components with it without manually calculating the absolute angle each time.
The existing surface should be inspected and approved before it is used as the reference.
Using Absolute Mode for Level Checking
Absolute mode is more appropriate when checking whether a surface is level.
A basic method is:
Clean the surface.
Place the LM320E securely.
Confirm that absolute mode is selected.
Select the required unit.
Allow the reading to stabilise.
Record the result.
Rotate the instrument if the procedure requires a reversal check.
Repeat the measurement.
Compare with the permitted tolerance.
Do not activate relative zero on the same surface and then claim that the surface is level.
Relative zero only removes the displayed difference from the selected position.
Using Absolute Mode for Pipe Slope
If a pipe drawing requires a 2% slope, select absolute measurement and percentage mode.
The instrument should then show the pipe’s actual slope according to the LM320E reference.
Also confirm:
The direction of fall
The measurement orientation
The pipe contact condition
Several positions along the pipe
The total elevation change
The reading after supports are tightened
Do not set the existing pipe as relative zero if the purpose is to confirm the actual 2% requirement.
Can You Use Relative Mode with Different Units?
Relative-angle differences may be viewed using the supported units.
These include:
Degrees
Percentage
mm/m
in/ft
Use the unit stated in the job requirement.
Do not compare one component in degrees and another in percentage without performing the correct conversion.
Every recorded value should include its unit.
How to Avoid Losing the Reference
A relative reference may be lost or changed when:
The mode is reset
The instrument is switched off
A control is pressed accidentally
The operator establishes a new zero
The battery runs out
Another person changes the setting
For important work:
Record the original absolute angle
Mark the reference location
Confirm relative zero before each comparison
Recheck the master reference regularly
Return to the original reference if the results appear unusual
Do not rely only on memory during a long installation.
Why Measurement Direction Must Remain the Same
Relative comparison is most reliable when the LM320E is positioned consistently.
Changing the direction can introduce differences caused by:
Surface shape
Contact position
Instrument orientation
Component curvature
Local irregularities
Mark:
The measurement point
The forward direction
The contact side
The required unit
This makes it easier for another operator to reproduce the measurement.
Do Not Create a Chain of References
A chain of references occurs when:
Bracket 1 is used to set bracket 2
Bracket 2 is then used to set bracket 3
Bracket 3 is used to set bracket 4
Small differences can accumulate through the series.
A better method is to compare every bracket with the same approved master reference.
This reduces cumulative error and keeps the installation linked to one known position.
Recheck After Tightening
A component may move when fasteners are tightened.
After adjustment:
Tighten the component according to the required procedure
Place the LM320E at the same marked position
Check the relative difference again
Check the absolute angle where necessary
Record the final result
If the value changes, investigate:
Bracket movement
Surface contact
Bolt sequence
Support deformation
Incorrect shimming
Instrument positioning
The setting is not complete until the final tightened position has been verified.
Common Absolute-Mode Mistakes
Common mistakes include:
Selecting the wrong unit
Measuring from an unsuitable surface
Checking only one direction
Ignoring the direction of slope
Recording a value without its unit
Comparing the result with an incorrect tolerance
Assuming displayed resolution equals accuracy
Using a local reading to represent a long structure
Confirm the entire measurement method, not only the number on the display.
Common Relative-Mode Mistakes
Common mistakes include:
Setting zero on an unapproved surface
Assuming relative zero means horizontally level
Changing the measurement direction
Resetting zero for every component
Failing to record the original angle
Using an unstable reference surface
Forgetting that relative mode is active
Accepting a matching angle in the wrong slope direction
Not rechecking after tightening
A stable relative reading is only useful when the original reference and measurement method are valid.
How to Confirm Which Mode Is Active
Before every important measurement:
Check the display indicator
Return the meter to the master reference
Confirm whether it shows the expected absolute or relative value
Verify the selected unit
Repeat the setup if the mode is uncertain
If the result does not make sense, stop and confirm the mode before adjusting the component.
Changing the installation based on an incorrect mode can create additional work.
Absolute Mode or Relative Mode Selection Guide
Use absolute mode for:
Checking horizontal level
Checking vertical position
Measuring actual pipe slope
Following a specified angle
Recording an inspection value
Comparing with a numerical tolerance
Use relative mode for:
Copying an existing angle
Matching repeated brackets
Comparing two components
Measuring deviation from a master reference
Following an approved inclined surface
Checking whether surfaces are parallel in angle
Some jobs require both modes.
Absolute mode confirms the master angle.
Relative mode helps reproduce it across additional components.
When Is the LM320E Not Suitable?
Another instrument or method may be required when:
The tolerance is tighter than the LM320E accuracy
The reference surface is very small
The component is strongly curved
Precision machinery alignment is required
Long-distance elevation must be transferred
The work requires surveying control
A certified measurement method is specified
The LM320E has a stated angle accuracy of ±0.2°.
Compare this specification with the job tolerance before using either absolute or relative mode for acceptance.
Who Can Benefit from Both Measurement Modes?
Absolute and relative modes may be useful for:
Machinery installers
Mechanical contractors
Steel fabricators
Pipe installers
Cabinet installers
Building maintenance teams
Renovation contractors
Quality-control personnel
Technical training centres
General industrial users
Customers in Selangor, Kuala Lumpur, Johor and Penang should identify whether they need the actual angle or only the difference between surfaces before beginning measurement.
For application advice, send MTM Precision a clear photo of the reference surface, component and required angle or tolerance.
MTM Precision Sdn Bhd
Showroom & Service Centre: No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
04 Oct 2026