How to Use Relative and Absolute Angle Modes on UNI-T LM320E Malaysia

How to Use Relative and Absolute Angle Modes on UNI-T LM320E Malaysia

 

Content

 

Published: 4 October 2026

 

The UNI-T LM320E Digital Angle Meter supports both absolute and relative angle measurement.

 

Absolute mode shows the instrument’s angle according to its normal reference.

 

Relative mode allows the user to set the current position as a temporary zero and measure the difference from that position.

 

These two modes are useful for different jobs.

 

Using the wrong mode can produce a reading that appears correct but does not answer the actual measurement requirement.

 

What Is Absolute Angle Measurement?

 

Absolute-angle mode shows the orientation of the LM320E according to its standard internal reference.

 

It is normally used when the customer wants to determine:

 

Whether a surface is horizontal

 

Whether a component is vertical

 

The actual angle of a bracket

 

The slope of a pipe

 

The inclination of a machine frame

 

Whether an installation matches a stated angle

 

The value can be displayed in:

 

Degrees

 

Percentage

 

mm/m

 

in/ft

 

The selected unit should match the drawing, specification or inspection procedure.

 

When Should You Use Absolute Mode?

 

Use absolute mode when:

 

A drawing states a required angle

 

A pipe must have a specific percentage slope

 

A machine base must be checked for level

 

A frame must be installed vertically

 

An inspection record needs the actual angle

 

The result must be compared with a numerical tolerance

 

For example, if a drawing requires a bracket angle of 30°, absolute mode should be used to check whether the bracket reaches the specified value.

 

What Is Relative Angle Measurement?

 

Relative mode allows the user to choose a current position and treat it as zero.

 

After the relative reference is set, the LM320E displays the difference between that reference and another position.

 

This is useful when the user wants to:

 

Compare two surfaces

 

Copy an existing angle

 

Match repeated components

 

Measure deviation from a selected reference

 

Work from a surface that is not horizontal

 

The relative result does not necessarily show the actual angle from the horizontal.

 

It shows the difference from the selected reference.

 

Simple Relative-Angle Example

 

Assume an existing bracket is installed at 25°.

 

The user wants to install another bracket at the same angle.

 

A possible method is:

 

Place the LM320E on the approved bracket.

 

Confirm that the instrument is stable.

 

Set the current position as the relative zero.

 

Move the meter to the new bracket.

 

Adjust the bracket until the relative reading approaches zero.

 

Tighten the bracket.

 

Recheck the result.

 

A relative reading near zero means that the two measured surfaces are at approximately the same angle.

 

It does not mean that both surfaces are horizontally level.

 

Why Relative Zero Does Not Mean Horizontal

 

This is one of the most important points when using relative mode.

 

If the LM320E is placed on a surface inclined at 20° and that position is set as zero, the display will show a relative value of zero.

 

The surface is still physically inclined at 20°.

 

The instrument is only showing that there is no difference from the selected reference.

 

Before accepting the measurement, confirm whether the requirement is:

 

Zero relative difference

 

Zero absolute angle

 

A specific absolute angle

 

These are not the same conditions.

 

Using Relative Mode to Copy an Existing Angle

 

Relative mode can help copy the angle of:

 

A fabricated bracket

 

An inclined shelf

 

A machine support

 

A steel frame

 

A pipe support

 

A cabinet panel

 

An existing structure

 

The original component must first be confirmed as the correct reference.

 

If the original angle is wrong, copying it will reproduce the same error.

 

How to Copy an Angle

 

A general procedure is:

 

Clean the original reference surface.

 

Place the LM320E in a repeatable direction.

 

Allow the reading to stabilise.

 

Confirm that the original component is approved.

 

Activate relative mode.

 

Move the meter to the new component.

 

Use the same measurement direction.

 

Adjust until the relative difference is acceptable.

 

Tighten the component.

 

Recheck in both relative and absolute modes if required.

 

The acceptance tolerance should come from the drawing or inspection procedure.

 

Using Relative Mode for Repeated Brackets

 

Relative mode is useful when several brackets must match one approved bracket.

 

Possible applications include:

 

Pipe supports

 

Cable-tray supports

 

Shelf brackets

 

Machine guards

 

Steel-frame members

 

Solar-panel supports

 

Fabricated mounting plates

 

A practical process is:

 

Select one approved master bracket

 

Mark its measurement point

 

Set it as the relative reference

 

Measure each new bracket at the same point

 

Maintain the same instrument direction

 

Record the deviation

 

Adjust each bracket

 

Recheck after tightening

 

Do not keep resetting zero on every new bracket.

 

Doing so can cause the reference to drift from one component to the next.

 

Use one confirmed reference whenever possible.

 

Using Relative Mode for Machinery Components

 

Maintenance teams may use relative mode to compare:

 

Two machine frames

 

Opposite support members

 

Parallel guards

 

Adjustable plates

 

Repeated mounting brackets

 

Inclined covers

 

The result can show whether one component differs from the selected reference.

 

However, relative mode does not measure:

 

Shaft offset

 

Coupling alignment

 

Pulley alignment

 

Machine-centre position

 

Soft foot

 

Distance between components

 

Specialised machinery-alignment tools may still be required.

 

Using Relative Mode for Pipe Installation

 

Relative mode may help compare the slope of several pipe sections or supports.

 

For example:

 

A correctly installed section can be used as the reference.

 

The LM320E can then be moved to the next section.

 

The relative result shows how much the new section differs from the reference.

 

Before using this method, confirm:

 

The original pipe section is correct

 

The instrument can sit securely

 

The measurement direction is consistent

 

The pipe diameter is suitable

 

The required slope direction is maintained

 

A zero relative difference does not prove that the overall pipe run has the correct elevation.

 

Long-distance elevation should be checked separately where necessary.

 

Using Relative Mode on a Non-Level Reference

 

Some installations must follow an existing inclined surface.

 

Examples include:

 

An inclined roof structure

 

A sloping machine frame

 

An existing ramp

 

A fabricated support

 

A drainage structure

 

A special architectural feature

 

Relative mode allows the existing surface to become the working reference.

 

The user can then compare new components with it without manually calculating the absolute angle each time.

 

The existing surface should be inspected and approved before it is used as the reference.

 

Using Absolute Mode for Level Checking

 

Absolute mode is more appropriate when checking whether a surface is level.

 

A basic method is:

 

Clean the surface.

 

Place the LM320E securely.

 

Confirm that absolute mode is selected.

 

Select the required unit.

 

Allow the reading to stabilise.

 

Record the result.

 

Rotate the instrument if the procedure requires a reversal check.

 

Repeat the measurement.

 

Compare with the permitted tolerance.

 

Do not activate relative zero on the same surface and then claim that the surface is level.

 

Relative zero only removes the displayed difference from the selected position.

 

Using Absolute Mode for Pipe Slope

 

If a pipe drawing requires a 2% slope, select absolute measurement and percentage mode.

 

The instrument should then show the pipe’s actual slope according to the LM320E reference.

 

Also confirm:

 

The direction of fall

 

The measurement orientation

 

The pipe contact condition

 

Several positions along the pipe

 

The total elevation change

 

The reading after supports are tightened

 

Do not set the existing pipe as relative zero if the purpose is to confirm the actual 2% requirement.

 

Can You Use Relative Mode with Different Units?

 

Relative-angle differences may be viewed using the supported units.

 

These include:

 

Degrees

 

Percentage

 

mm/m

 

in/ft

 

Use the unit stated in the job requirement.

 

Do not compare one component in degrees and another in percentage without performing the correct conversion.

 

Every recorded value should include its unit.

 

How to Avoid Losing the Reference

 

A relative reference may be lost or changed when:

 

The mode is reset

 

The instrument is switched off

 

A control is pressed accidentally

 

The operator establishes a new zero

 

The battery runs out

 

Another person changes the setting

 

For important work:

 

Record the original absolute angle

 

Mark the reference location

 

Confirm relative zero before each comparison

 

Recheck the master reference regularly

 

Return to the original reference if the results appear unusual

 

Do not rely only on memory during a long installation.

 

Why Measurement Direction Must Remain the Same

 

Relative comparison is most reliable when the LM320E is positioned consistently.

 

Changing the direction can introduce differences caused by:

 

Surface shape

 

Contact position

 

Instrument orientation

 

Component curvature

 

Local irregularities

 

Mark:

 

The measurement point

 

The forward direction

 

The contact side

 

The required unit

 

This makes it easier for another operator to reproduce the measurement.

 

Do Not Create a Chain of References

 

A chain of references occurs when:

 

Bracket 1 is used to set bracket 2

 

Bracket 2 is then used to set bracket 3

 

Bracket 3 is used to set bracket 4

 

Small differences can accumulate through the series.

 

A better method is to compare every bracket with the same approved master reference.

 

This reduces cumulative error and keeps the installation linked to one known position.

 

Recheck After Tightening

 

A component may move when fasteners are tightened.

 

After adjustment:

 

Tighten the component according to the required procedure

 

Place the LM320E at the same marked position

 

Check the relative difference again

 

Check the absolute angle where necessary

 

Record the final result

 

If the value changes, investigate:

 

Bracket movement

 

Surface contact

 

Bolt sequence

 

Support deformation

 

Incorrect shimming

 

Instrument positioning

 

The setting is not complete until the final tightened position has been verified.

 

Common Absolute-Mode Mistakes

 

Common mistakes include:

 

Selecting the wrong unit

 

Measuring from an unsuitable surface

 

Checking only one direction

 

Ignoring the direction of slope

 

Recording a value without its unit

 

Comparing the result with an incorrect tolerance

 

Assuming displayed resolution equals accuracy

 

Using a local reading to represent a long structure

 

Confirm the entire measurement method, not only the number on the display.

 

Common Relative-Mode Mistakes

 

Common mistakes include:

 

Setting zero on an unapproved surface

 

Assuming relative zero means horizontally level

 

Changing the measurement direction

 

Resetting zero for every component

 

Failing to record the original angle

 

Using an unstable reference surface

 

Forgetting that relative mode is active

 

Accepting a matching angle in the wrong slope direction

 

Not rechecking after tightening

 

A stable relative reading is only useful when the original reference and measurement method are valid.

 

How to Confirm Which Mode Is Active

 

Before every important measurement:

 

Check the display indicator

 

Return the meter to the master reference

 

Confirm whether it shows the expected absolute or relative value

 

Verify the selected unit

 

Repeat the setup if the mode is uncertain

 

If the result does not make sense, stop and confirm the mode before adjusting the component.

 

Changing the installation based on an incorrect mode can create additional work.

 

Absolute Mode or Relative Mode Selection Guide

 

Use absolute mode for:

 

Checking horizontal level

 

Checking vertical position

 

Measuring actual pipe slope

 

Following a specified angle

 

Recording an inspection value

 

Comparing with a numerical tolerance

 

Use relative mode for:

 

Copying an existing angle

 

Matching repeated brackets

 

Comparing two components

 

Measuring deviation from a master reference

 

Following an approved inclined surface

 

Checking whether surfaces are parallel in angle

 

Some jobs require both modes.

 

Absolute mode confirms the master angle.

 

Relative mode helps reproduce it across additional components.

 

When Is the LM320E Not Suitable?

 

Another instrument or method may be required when:

 

The tolerance is tighter than the LM320E accuracy

 

The reference surface is very small

 

The component is strongly curved

 

Precision machinery alignment is required

 

Long-distance elevation must be transferred

 

The work requires surveying control

 

A certified measurement method is specified

 

The LM320E has a stated angle accuracy of ±0.2°.

 

Compare this specification with the job tolerance before using either absolute or relative mode for acceptance.

 

Who Can Benefit from Both Measurement Modes?

 

Absolute and relative modes may be useful for:

 

Machinery installers

 

Mechanical contractors

 

Steel fabricators

 

Pipe installers

 

Cabinet installers

 

Building maintenance teams

 

Renovation contractors

 

Quality-control personnel

 

Technical training centres

 

General industrial users

 

Customers in Selangor, Kuala Lumpur, Johor and Penang should identify whether they need the actual angle or only the difference between surfaces before beginning measurement.

 

For application advice, send MTM Precision a clear photo of the reference surface, component and required angle or tolerance.

 

MTM Precision Sdn Bhd

 

Showroom & Service Centre: No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia

 

Tel: 03-8080 7172

 

WhatsApp: +6016-660 7346

 

Email: mtmpre@yahoo.com

 

Website: www.mtmpre.com.my


 

04 Oct 2026