The UNI-T LM320E has magnetic mounting surfaces at the bottom and rear.

 

These magnets allow the angle meter to attach to suitable ferrous-steel components during measurement.

 

If the LM320E does not stick properly, the instrument is not necessarily faulty.

 

The problem may be caused by:

 

Non-magnetic material

 

Weakly magnetic stainless steel

 

A thick surface coating

 

Rust

 

Dirt

 

Metal particles

 

A curved surface

 

Insufficient contact area

 

A steep or unstable mounting position

 

Damage to the magnetic surface

 

Before using the LM320E, confirm that the measurement surface is suitable for magnetic mounting.

 

Which Materials Can Hold the LM320E Magnet?

 

The LM320E magnet is intended for suitable ferrous-metal surfaces.

 

These commonly include:

 

Mild steel

 

Carbon steel

 

Some iron components

 

Steel machinery frames

 

Steel brackets

 

Fabricated steel supports

 

Metal machine bodies

 

The holding strength depends on:

 

Material type

 

Steel thickness

 

Surface condition

 

Contact area

 

Coating thickness

 

Instrument orientation

 

A magnet may hold strongly on one steel component but weakly on another.

 

Which Materials Will Not Hold the Magnet?

 

The LM320E magnetic base will not attach properly to many common materials.

 

These include:

 

Aluminium

 

Copper

 

Brass

 

Plastic

 

Timber

 

Concrete

 

Glass

 

Ceramic tiles

 

Fibreglass

 

The angle-measurement function can still be used if the instrument is placed or supported securely.

 

Magnetic mounting is only one positioning method.

 

Why Does the Magnet Not Stick to Stainless Steel?

 

Not every stainless-steel grade is strongly magnetic.

 

Some stainless-steel surfaces may provide:

 

Strong attraction

 

Weak attraction

 

Almost no attraction

 

The response depends on the stainless-steel composition, manufacturing process and surface condition.

 

Do not assume that the LM320E will hold securely just because the component is made from stainless steel.

 

Test the magnetic attraction before releasing the instrument.

 

If the holding force is weak, use a suitable non-magnetic mounting or supporting method.

 

Surface Coating Can Reduce Magnetic Holding

 

The magnet holds the steel beneath the coating.

 

A thick gap between the magnet and steel can reduce the holding force.

 

Possible barriers include:

 

Thick paint

 

Powder coating

 

Rubber lining

 

Protective film

 

Plastic covering

 

Insulation

 

Labels

 

Corrosion protection layers

 

Do not remove a protective coating unless the owner or work procedure permits it.

 

Select another mounting position or support the instrument safely.

 

Rust Can Affect Contact

 

Heavy rust can create an uneven gap between the LM320E and the steel.

 

This may cause:

 

Reduced magnetic attraction

 

Instrument rocking

 

Unstable readings

 

Poor repeatability

 

Sliding

 

Loose rust should not remain between the instrument and the measurement surface.

 

Use an approved clean reference area.

 

Do not grind, scrape or remove corrosion from customer equipment without permission.

 

Check for Dirt and Oil

 

Dust, oil and workshop contamination can reduce surface contact.

 

Before attaching the LM320E:

 

Wipe the instrument base

 

Clean the steel surface

 

Remove oil

 

Remove loose dirt

 

Check for adhesive residue

 

Inspect for moisture

 

The cleaned surface should remain safe to use and should not be damaged by the cleaning method.

 

Metal Particles on the Magnet

 

The LM320E magnetic surfaces can collect:

 

Steel filings

 

Grinding debris

 

Drilling swarf

 

Small screws

 

Wire fragments

 

Rust particles

 

These particles prevent the meter from sitting flat.

 

They can also scratch painted or finished surfaces.

 

Inspect the magnetic base before every important measurement.

 

Remove particles carefully and keep them away from the instrument housing and charging connection.

 

Why Does the LM320E Slide Down?

 

The LM320E may attach to a vertical surface but slowly slide downward.

 

Possible causes include:

 

Weak magnetic attraction

 

A smooth painted surface

 

Oil or moisture

 

A thick coating

 

A small contact area

 

A strongly inclined position

 

Instrument vibration

 

A curved component

 

Do not continue measuring if the instrument moves.

 

A sliding meter can produce an incorrect angle and may fall.

 

Support the instrument or select another measurement position.

 

Curved Surfaces Reduce Contact Area

 

A flat magnetic base cannot make full contact with a strongly curved surface.

 

This commonly occurs on:

 

Small steel pipes

 

Round tanks

 

Cylindrical machine parts

 

Handrails

 

Curved housings

 

The magnet may touch only a narrow part of the surface.

 

This can reduce holding strength and allow the meter to rock.

 

A stable flat bracket, support or verified fixture may provide a better measurement surface.

 

Thin Steel May Provide Weaker Holding

 

Very thin steel components may provide less magnetic holding than thicker steel.

 

Examples include:

 

Thin sheet-metal panels

 

Machine guards

 

Cabinet skins

 

Lightweight covers

 

Ducting

 

The panel may also flex when the LM320E is attached.

 

A stable reading on a flexible panel may not represent the main machine frame or structure.

 

Select a rigid reference area where possible.

 

Checking the Bottom Magnet

 

The bottom magnetic surface is useful when the LM320E sits on:

 

Horizontal steel

 

Inclined steel supports

 

Machine bases

 

Fabricated brackets

 

Large steel pipes with suitable contact

 

Before releasing the instrument:

 

Confirm full contact

 

Check that it does not rock

 

Check that it cannot slide

 

Allow the display to stabilise

 

Repeat the placement

 

Do not assume that the bottom magnet will hold safely on a steeply inclined surface.

 

Checking the Rear Magnet

 

The rear magnetic surface allows the LM320E to attach to the side of a steel component.

 

This may be useful for:

 

Vertical machine frames

 

Steel columns

 

Large brackets

 

Fabricated panels

 

Equipment supports

 

Check whether the rear surface is fully contacting the steel.

 

Raised bolts, welds, labels and curved surfaces can prevent proper contact.

 

Magnetic Holding Is Not a Safety Attachment

 

The LM320E magnet is intended to support positioning during measurement.

 

It should not be treated as:

 

A certified fall-arrest attachment

 

A lifting device

 

A permanent equipment mount

 

A vibration-resistant safety fixing

 

A secure attachment for moving machinery

 

Do not leave the instrument attached where it could fall onto:

 

Workers

 

Operating machinery

 

Electrical equipment

 

Production materials

 

Vehicles

 

Finished products

 

Use appropriate access and safety controls when working at height.

 

Do Not Leave the LM320E on Operating Machinery

 

Operating machinery may produce:

 

Vibration

 

Heat

 

Oil mist

 

Sudden movement

 

Impact

 

Rotating hazards

 

These conditions can cause the LM320E to move or fall.

 

Where possible, isolate the machinery according to the site’s approved safety procedure before attaching the instrument.

 

Do not reach into hazardous areas simply because the meter has a magnetic base.

 

Can You Hold the LM320E by Hand?

 

The instrument may be held against a non-magnetic surface for a quick general check.

 

However, hand pressure can tilt the meter and affect repeatability.

 

Possible problems include:

 

Uneven pressure

 

Finger movement

 

Instrument rotation

 

Poor contact

 

Different positioning between readings

 

For important measurements, use a stable fixture or support that does not interfere with the contact surface.

 

Using a Temporary Fixture

 

A temporary fixture may help when the surface is non-magnetic or curved.

 

The fixture should:

 

Hold the LM320E securely

 

Provide a flat reference

 

Maintain the correct direction

 

Avoid pressing the meter at an angle

 

Remain stable during adjustment

 

Represent the component correctly

 

The fixture should be checked before it is used for acceptance measurements.

 

A stable but incorrectly aligned fixture can produce a repeatable wrong result.

 

Can Double-Sided Tape Be Used?

 

Double-sided tape is generally unsuitable for accurate direct-contact angle measurement because it may:

 

Create an uneven layer

 

Compress under pressure

 

Allow movement

 

Leave adhesive residue

 

Change the contact angle

 

Damage the surface

 

Do not attach the LM320E using an improvised method without considering how the added layer affects measurement.

 

Use a suitable mechanical support or verified fixture instead.

 

Protecting Painted Steel

 

The magnetic base may collect particles that scratch painted equipment.

 

Before placing the LM320E on a finished surface:

 

Inspect the magnet

 

Remove all metal debris

 

Clean the contact area

 

Avoid sliding the meter

 

Place and lift it carefully

 

Follow the equipment owner’s protection requirements

 

Adding a thick protective pad can reduce magnetic strength and change the measurement contact.

 

If protection is required, confirm that the selected method does not affect the result.

 

How to Test Magnetic Holding Safely

 

Before taking a measurement:

 

Identify the material.

 

Clean the contact surface.

 

Inspect the LM320E magnetic base.

 

Place the instrument carefully.

 

Keep one hand close to prevent a fall.

 

Check whether the instrument sits flat.

 

Apply a light movement check.

 

Confirm that it does not slide.

 

Allow the reading to stabilise.

 

Remove the instrument if the holding force is uncertain.

 

Do not perform the test over people, operating equipment or fragile items.

 

Why Does the Reading Change When Magnetically Mounted?

 

A reading may change because:

 

The instrument is sliding

 

The magnetic surface is uneven

 

Metal debris creates a gap

 

The component is curved

 

The steel panel flexes

 

The instrument is placed near a weld

 

The contact point changes

 

Machinery vibration is present

 

Remove and inspect the setup.

 

Do not average changing readings until the cause has been corrected.

 

How to Compare Magnetic and Non-Magnetic Placement

 

If the result appears unusual:

 

Choose a stable flat reference surface.

 

Clean the LM320E.

 

Place it using the bottom contact surface.

 

Record the reading.

 

Reposition it carefully.

 

Repeat the measurement.

 

Compare the results.

 

The purpose is to check placement repeatability.

 

This does not replace calibration or confirm that every magnetic surface is suitable.

 

Signs of Possible Magnetic-Base Damage

 

Inspect the LM320E if:

 

The base is visibly deformed

 

The contact surface is chipped

 

The magnet is loose

 

The housing has separated

 

The instrument rocks on a verified flat surface

 

The unit has been dropped

 

The holding strength has changed significantly

 

Stop relying on magnetic mounting if the physical condition is uncertain.

 

The instrument may require inspection before further use.

 

Magnetic Base vs Four-Sided Magnetic Mounting

 

The LM320E has magnetic surfaces at the bottom and rear.

 

The LM320F provides magnetic mounting on:

 

Bottom

 

Rear

 

Left side

 

Right side

 

Choose the LM320F if the application genuinely requires attachment from more directions.

 

The additional magnets do not increase the official angle accuracy.

 

They provide more mounting-position options.

 

Common Magnetic-Mounting Mistakes

 

Common mistakes include:

 

Assuming every metal is magnetic

 

Releasing the instrument before testing the hold

 

Attaching it to a small curved pipe

 

Ignoring thick paint

 

Leaving metal filings on the magnet

 

Sliding the meter across a finished surface

 

Using the magnet as a permanent mount

 

Leaving the meter on operating machinery

 

Working above people without fall protection

 

Accepting a reading while the meter is moving

 

Magnetic convenience should not replace safe and repeatable positioning.

 

When Is Another Instrument More Suitable?

 

Another tool or method may be more suitable when:

 

The surface is non-magnetic

 

The component is strongly curved

 

There is no stable contact area

 

The instrument must remain mounted permanently

 

The work is performed at height

 

The surface is hot

 

Machinery cannot be safely stopped

 

The required tolerance is tighter than ±0.2°

 

Choose the instrument and mounting method according to both the measurement and safety requirements.

 

Who Should Check Magnetic Compatibility?

 

Magnetic compatibility should be evaluated by:

 

Machinery installers

 

Mechanical contractors

 

Steel fabricators

 

Pipe installers

 

Building maintenance teams

 

Cabinet installers

 

Factory maintenance personnel

 

Quality-control inspectors

 

Renovation contractors

 

Technical training centres

 

Customers in Selangor, Kuala Lumpur, Johor and Penang can send MTM Precision a clear photo showing the material, component shape and intended mounting position.

 

For initial assessment, WhatsApp a clear photo of the LM320E magnetic base, model label and the surface where it does not attach properly.

 

MTM Precision Sdn Bhd

 

Showroom & Service Centre: No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia

 

Tel: 03-8080 7172

 

WhatsApp: +6016-660 7346

 

Email: mtmpre@yahoo.com

 

Website: www.mtmpre.com.my


 

04 Oct 2026