The UNI-T LM320E Digital Angle Meter can assist with checking the inclination of floors, ramps, roofs and other sloping surfaces.

 

It can display the measured slope in:

 

Degrees

 

Percentage

 

mm/m

 

in/ft

 

This allows contractors and maintenance teams to compare a local surface angle with a drawing or specified slope.

 

However, the LM320E measures only the area where the instrument is placed.

 

A correct reading at one point does not confirm that an entire floor, ramp or roof has a consistent slope.

 

What Does the LM320E Measure?

 

The LM320E measures its own orientation when placed against a surface.

 

It has:

 

4 × 90° measurement range

 

±0.2° stated angle accuracy

 

0.05° resolution

 

Absolute and relative measurement

 

Two laser reference lines

 

Bottom and rear magnetic mounting

 

Rotating colour display

 

It may be used for general slope checking when the surface provides stable and representative contact.

 

It does not directly measure:

 

Surface height

 

Distance

 

Floor flatness across a room

 

Elevation difference between remote points

 

Drainage performance

 

Roof leakage

 

Structural deflection

 

Additional tools may be required for these checks.

 

Degrees vs Percentage Slope

 

Degrees and percentage describe slope differently.

 

Degrees represent an angle.

 

Percentage represents the vertical change divided by the horizontal distance, multiplied by 100.

 

They are not interchangeable.

 

Approximate examples include:

 

1° equals approximately 1.75%

 

2° equals approximately 3.49%

 

3° equals approximately 5.24%

 

5° equals approximately 8.75%

 

If a drawing specifies 2%, do not set the surface to 2°.

 

A 2% slope is approximately 1.15°.

 

Percentage vs mm/m

 

The relationship between percentage and mm/m is direct.

 

Examples include:

 

0.5% equals 5 mm/m

 

1% equals 10 mm/m

 

1.5% equals 15 mm/m

 

2% equals 20 mm/m

 

3% equals 30 mm/m

 

The selected LM320E unit should match the project requirement.

 

Always record the unit together with the numerical result.

 

Can the LM320E Check Floor Slope?

 

The LM320E may be used to check the local slope of a suitable floor surface.

 

Possible applications include:

 

Bathroom floors

 

Balconies

 

Plant rooms

 

Kitchen areas

 

Drainage zones

 

External walkways

 

Loading areas

 

Workshop floors

 

The contact surface should be:

 

Clean

 

Hard

 

Stable

 

Free from loose debris

 

Large enough for the instrument

 

Representative of the floor condition

 

Rough concrete, tiles with raised joints or textured surfaces may affect how the instrument sits.

 

Why Is One Floor Reading Not Enough?

 

A floor may have:

 

Local high points

 

Low spots

 

Uneven screed

 

Tile lippage

 

Changes in slope

 

Depressions

 

Surface waviness

 

Different drainage directions

 

A single reading shows only the angle at that location.

 

Take measurements:

 

Near the drain

 

Between the drain and perimeter

 

Along the intended flow direction

 

Across several sections

 

At suspected ponding areas

 

The number and arrangement of test points should match the inspection purpose.

 

Checking a Floor Toward a Drain

 

A floor designed for drainage should normally fall toward the intended outlet.

 

A basic check may include:

 

Identify the drain.

 

Mark several paths toward it.

 

Clean each measurement area.

 

Place the LM320E in the direction of expected flow.

 

Record the slope and direction.

 

Repeat at several distances.

 

Check for local reverse slopes.

 

Compare with the drawing or specification.

 

A correct slope at one point does not prove that water can travel continuously to the drain.

 

Can the LM320E Identify Ponding Areas?

 

The LM320E may help identify local areas with:

 

Insufficient slope

 

Reverse slope

 

Changing direction

 

An unexpected flat section

 

However, ponding may also be caused by:

 

Local depressions

 

Uneven tile edges

 

Blocked drains

 

Poor waterproofing details

 

Surface roughness

 

Incorrect drainage layout

 

A local angle reading should be combined with visual inspection and the approved test method.

 

Do not use water testing without considering site safety and waterproofing requirements.

 

Measuring Across Tile Joints

 

Tile joints can prevent the LM320E from sitting consistently.

 

Possible problems include:

 

One edge resting on a tile

 

Another edge resting on grout

 

Raised tile corners

 

Different tile levels

 

Uneven grout depth

 

For more repeatable measurements, a suitable straightedge may be placed across the surface.

 

The straightedge must be:

 

Rigid

 

Flat

 

Clean

 

Long enough for the intended check

 

Placed in the correct direction

 

The LM320E can then measure the angle of the straightedge.

 

This method should match the inspection requirement.

 

Using a Straightedge on Floors

 

A longer straightedge can help bridge small local irregularities.

 

It may be useful when checking:

 

General floor fall

 

A longer drainage path

 

Changes between tiles

 

Surface consistency

 

The straightedge does not eliminate every problem.

 

It may bridge over a low spot or rest on two high points.

 

The result should be interpreted according to the required inspection method.

 

Can the LM320E Measure Ramp Slope?

 

The LM320E can measure the local angle of a ramp.

 

Possible ramp applications include:

 

Pedestrian ramps

 

Loading ramps

 

Warehouse ramps

 

Vehicle access ramps

 

Equipment ramps

 

Temporary access structures

 

Before measurement:

 

Confirm the required slope

 

Identify the ramp direction

 

Select the correct unit

 

Choose representative test points

 

Check the surface condition

 

Measure at several locations

 

The LM320E does not determine whether a ramp complies with building regulations or accessibility requirements by itself.

 

Compliance may also depend on dimensions, landings, handrails, edge protection and other design requirements.

 

Checking the Entire Ramp

 

A ramp may have different slopes at:

 

The lower transition

 

The central section

 

The upper transition

 

Landings

 

Side edges

 

Take readings at several positions.

 

Also consider:

 

Total rise

 

Horizontal run

 

Ramp length

 

Cross fall

 

Surface evenness

 

A local reading should be compared with overall dimensional measurements.

 

Cross-Slope on a Ramp

 

A ramp may have both:

 

Longitudinal slope

 

Cross-slope

 

The longitudinal slope runs in the direction of travel.

 

The cross-slope runs from one side to the other.

 

To measure them separately:

 

Align the LM320E with the direction of travel for longitudinal slope.

 

Rotate it 90° for cross-slope.

 

Record both results with their directions.

 

Do not combine the two readings or measure diagonally unless the procedure specifically requires it.

 

Can the LM320E Measure Roof Slope?

 

The LM320E may measure the local angle of an accessible and stable roof component.

 

Possible measurement points include:

 

Roof panels

 

Steel rafters

 

Support members

 

Trusses

 

Purlins

 

Roofing frames

 

The user must follow appropriate work-at-height and roof-access procedures.

 

Do not access a roof solely to take an LM320E reading without:

 

Approved access

 

Fall protection

 

Surface assessment

 

Weather evaluation

 

Site permission

 

Safe working procedures

 

The instrument’s magnetic base is not a fall-protection device.

 

Using the Magnetic Base on Metal Roofing

 

The magnetic base may attach to suitable ferrous-steel roof components.

 

However, magnetic holding can be affected by:

 

Thin sheet metal

 

Protective coatings

 

Surface curvature

 

Corrugation

 

Moisture

 

Dust

 

Steep inclination

 

Do not release the LM320E if the holding force is uncertain.

 

A sliding instrument could fall from the roof and cause injury or damage.

 

Keep the meter secured according to the site’s safe-working method.

 

Corrugated Roof Surfaces

 

Corrugated or profiled roof sheets may not provide a flat contact area.

 

The LM320E may:

 

Rock

 

Sit at a local profile angle

 

Slide

 

Produce inconsistent readings

 

Fail to represent the overall roof pitch

 

A suitable verified straightedge or structural member may provide a better reference.

 

Do not assume that the top of one roof corrugation represents the full roof slope.

 

Checking Roof Pitch from a Rafter

 

Where safely accessible, a flat rafter or structural member may provide a more stable measurement surface than a profiled roof sheet.

 

Before using it as the reference:

 

Confirm that it follows the roof pitch

 

Check for twist

 

Avoid welded irregularities

 

Choose a flat face

 

Measure more than one member

 

A structural component may differ from the finished roof surface because of construction tolerances.

 

Roof Slope vs Roof Drainage Performance

 

The LM320E can measure a local angle.

 

It cannot confirm:

 

Waterproofing quality

 

Gutter capacity

 

Outlet capacity

 

Blocked drainage

 

Roof-sheet overlap

 

Flashing condition

 

Leak paths

 

Structural movement

 

A roof with an apparently suitable slope may still experience leakage or ponding for other reasons.

 

A complete roof assessment may require visual inspection and specialist evaluation.

 

Using the Laser Lines on a Slope

 

The LM320E’s two laser lines can extend a visible reference from the measured angle.

 

They may help with:

 

Positioning nearby supports

 

Transferring an angle

 

Aligning brackets

 

Following an inclined direction

 

Marking another point

 

The laser lines follow the physical position of the instrument.

 

They do not independently verify the slope.

 

Bright sunlight may also make the lines difficult to see during outdoor work.

 

Relative Mode for Matching Slopes

 

Relative mode may help compare:

 

Two roof supports

 

Several ramp sections

 

Repeated floor screeds

 

Matching inclined panels

 

Separate brackets

 

An approved surface can be set as the temporary zero reference.

 

Other surfaces can then be checked for deviation from it.

 

A zero relative reading means the angles match.

 

It does not mean the surfaces are horizontally level or located at the same elevation.

 

Absolute Mode for Specified Slope

 

Use absolute mode when the drawing states:

 

A degree value

 

A percentage slope

 

An mm/m requirement

 

An in/ft requirement

 

Select the same unit on the LM320E.

 

Confirm the direction of fall and repeat the measurement at several locations.

 

Do not use relative mode when the objective is to verify an actual specified slope unless the approved reference itself has been confirmed.

 

Common Floor-Slope Measurement Mistakes

 

Common mistakes include:

 

Measuring over loose debris

 

Placing the meter across a tile joint

 

Checking only one point

 

Ignoring the drainage direction

 

Confusing degrees with percentage

 

Using a short local reading for an entire room

 

Failing to identify reverse slope

 

Recording the number without its unit

 

Assuming slope alone proves drainage performance

 

The result should be combined with an appropriate inspection plan.

 

Common Ramp-Measurement Mistakes

 

Common mistakes include:

 

Checking only the centre of the ramp

 

Ignoring transitions

 

Not measuring cross-slope

 

Using the wrong direction

 

Confusing ramp length with horizontal run

 

Relying on the LM320E for regulatory compliance

 

Failing to measure total rise

 

A ramp assessment may require dimensional and regulatory checks in addition to local angle measurement.

 

Common Roof-Measurement Mistakes

 

Common mistakes include:

 

Working without approved fall protection

 

Measuring on a corrugated profile

 

Assuming the magnet is a safety attachment

 

Using a wet or dusty surface

 

Taking only one reading

 

Ignoring structural twist

 

Relying on a local pitch reading to diagnose leakage

 

Safety and measurement suitability must both be evaluated before roof work begins.

 

When Is Another Instrument Required?

 

Another instrument or method may be more suitable when:

 

Long-distance elevation must be checked

 

The surface is very uneven

 

A complete floor-flatness survey is required

 

The ramp must be assessed for regulatory compliance

 

The roof is inaccessible

 

Survey-grade results are required

 

The tolerance is tighter than ±0.2°

 

A large area must be mapped

 

Possible alternatives include:

 

Laser level

 

Rotary laser

 

Automatic level

 

Total station

 

Digital level

 

Long straightedge

 

Specialised floor-testing equipment

 

The correct choice depends on the scale, tolerance and purpose of the inspection.

 

Who Can Use the LM320E for Slope Checking?

 

The LM320E may be useful for:

 

Renovation contractors

 

Flooring contractors

 

Building maintenance teams

 

Roofing contractors

 

Mechanical contractors

 

Facility-management teams

 

Drainage contractors

 

Steel fabricators

 

Quality-control personnel

 

Technical training centres

 

Contractors in Selangor, Kuala Lumpur, Johor and Penang should confirm the required slope, measurement direction and surface condition before using the LM320E.

 

For application advice, send MTM Precision a clear photo showing the floor, ramp or roof surface together with the required slope and working distance.

 

MTM Precision Sdn Bhd

 

Showroom & Service Centre: No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia

 

Tel: 03-8080 7172

 

WhatsApp: +6016-660 7346

 

Email: mtmpre@yahoo.com

 

Website: www.mtmpre.com.my


 

04 Oct 2026