How to Monitor Indoor Air Quality for ESG Workplace Records Malaysia
How to Monitor Indoor Air Quality for ESG Workplace Records Malaysia
When a company begins collecting ESG workplace data, indoor air quality may be one of the environmental conditions it wants to monitor.
However, placing one air-quality monitor near the office entrance and recording a single reading may not represent the entire workplace.
Conditions can vary between:
Offices
Meeting rooms
Production areas
Warehouses
Laboratories
Loading bays
Air-conditioned rooms
Areas near chemicals or cleaning materials
So, where should you measure, which parameters are useful and how should the readings be recorded?
1. Start with Occupied Work Areas
Begin in areas where employees spend significant time.
Possible locations include:
General offices
Workstations
Meeting rooms
Control rooms
Quality-control rooms
Enclosed production areas
Depending on the instrument, record:
COâ‚‚
PM2.5
PM10
TVOC
Temperature
Relative humidity
This provides a reference that can be compared with other locations.
Do not assume that one office reading represents the warehouse or production floor.
2. Measure Meeting Rooms During Use
Meeting rooms can experience changing air conditions because several people may occupy a relatively small enclosed space.
Compare:
Empty Meeting Room → Measure
Meeting in Progress → Measure
After Door Opens → Measure Again
COâ‚‚ readings may change as occupancy and ventilation conditions change.
A higher COâ‚‚ reading does not automatically identify a fault in the air-conditioning system. It indicates that occupancy and ventilation conditions should be reviewed.
Record:
Number of occupants
Time
Door position
Air-conditioning status
Meeting duration
Measurement result
Without this context, the reading may be difficult to interpret.
3. Check Production Areas Separately
Production areas may have different conditions from offices.
Possible influences include:
Dust
Machinery
Material handling
Heat
Process emissions
Open doors
Local ventilation
Cleaning activities
Take measurements at representative work locations rather than only at the edge of the production floor.
For larger factories, divide the area into zones.
For example:
Production Zone A → Record
Production Zone B → Record
Packing Area → Record
Quality-Control Area → Record
The objective is to identify meaningful differences between work areas.
4. Monitor PM2.5 During Haze
During haze conditions in Malaysia, fine particles from outdoor air may enter offices, factories and warehouses.
Useful comparison points include:
Outdoor Entrance Area → PM2.5
Reception Area → PM2.5
Office Interior → PM2.5
Air-Conditioned Room → PM2.5
Loading Bay → PM2.5
A portable air-quality monitor can help personnel observe how readings differ between open and enclosed areas.
The result may be influenced by:
Door-opening frequency
Building leakage
Ventilation
Filtration
Indoor activities
Outdoor conditions
An indoor reading should not automatically be treated as an official outdoor air-quality index.
5. Check Loading Bays and Entrances
Loading bays experience frequent contact with outdoor air.
Possible influences include:
Lorries
Forklifts
Open doors
Dust
Heat
Rain
Outdoor haze
Nearby road traffic
Compare:
Loading Bay → Air-quality reading
with
Internal Storage Area → Air-quality reading
This can help determine whether the entrance area is noticeably different from deeper parts of the building.
Record whether vehicles were operating during the measurement.
6. Measure Warehouse Conditions
Warehouses may have changing conditions between racks, external walls and internal storage zones.
Possible measurement points include:
Main storage area
Between storage racks
Rear warehouse
External wall
Loading area
Ventilation outlet
Reported problem location
Temperature and humidity may be especially important for stored materials.
PM2.5 may also be useful where dust or outdoor-air entry is a concern.
A portable monitor is suitable for comparing several points during one inspection.
7. Check Areas Near Chemicals Carefully
TVOC readings may change around areas where volatile materials are used or stored.
Possible sources include:
Paint
Adhesive
Solvent
Cleaning chemical
Ink
Coating material
Fuel
Recently installed furniture or renovation materials
Compare:
Normal Area → TVOC reading
Chemical-Use Area → TVOC reading
Before Activity → Record
During or After Activity → Record
A general TVOC monitor provides a broad indication of volatile organic compounds.
It normally does not identify the exact chemical present.
If a specific substance must be measured, a suitable dedicated instrument or sampling method may be required.
8. Check Temperature and Relative Humidity
Temperature and relative humidity provide important context for air-quality readings.
Measure them together with other parameters when possible.
Possible locations include:
Occupied office
Production floor
Warehouse
Laboratory
Server room
External wall area
HVAC outlet area
Compare:
Air-Conditioned Area → Temperature + RH
Non-Air-Conditioned Area → Temperature + RH
Main Storage Zone → Temperature + RH
Reported Damp Area → Temperature + RH
A high humidity reading does not automatically prove that a water leak exists.
Further building or moisture investigation may be required.
9. Avoid Measuring Directly at an Air Outlet
Placing the monitor directly under an air-conditioning outlet may produce a reading that represents the supply air rather than the normal occupied zone.
Similarly, avoid placing the instrument directly beside:
Open windows
External doors
Fans
Air purifiers
Local exhaust outlets
Chemical containers
Direct sunlight
Strong heat sources
Unless these locations are the specific subject of the investigation, choose a position that represents the area being assessed.
10. Allow the Reading to Respond
When moving a monitor between areas with different conditions, allow sufficient time for the readings to respond.
Do not walk rapidly from one point to another and record every result immediately.
For a consistent inspection:
Use the same instrument
Follow the same route
Use similar measurement positions
Record at similar times
Note occupancy and activities
Allow readings to respond
Record unusual conditions
This makes comparisons more useful.
A Simple Workplace Air-Quality Route
A basic inspection route may be:
Point 1 – Reception
↓
Point 2 – Main Office
↓
Point 3 – Meeting Room
↓
Point 4 – Production Area
↓
Point 5 – Warehouse
↓
Point 6 – Loading Bay
↓
Point 7 – Reported Problem Area
Record the relevant parameters at each location.
Not every parameter will be equally important in every area.
Create an Indoor Air-Quality Record
A basic monitoring record can include:
Date
Time
Location
Occupancy
Activity
Air-conditioning status
COâ‚‚
PM2.5
PM10
TVOC
Temperature
Relative humidity
Observation
For example:
LocationParametersOperating ConditionObservationMain OfficeCOâ‚‚, PM2.5, TVOC, Temperature, RHNormal occupancyReference areaMeeting RoomCOâ‚‚, Temperature, RHMeeting in progressRecord occupantsProduction ZonePM2.5, Temperature, RHMachines operatingNote production activityWarehousePM2.5, Temperature, RHNormal storageCompare rack areasLoading BayPM2.5, Temperature, RHDoor openNote vehicle movement
Use the same table for repeated inspections.
Spot Checking or Continuous Monitoring?
A portable monitor is suitable for:
Comparing several rooms
Walk-around inspections
Initial investigation
Checking reported problem areas
Temporary haze monitoring
Before-and-after comparisons
Continuous monitoring may be more useful when:
Conditions change throughout the day
COâ‚‚ rises only during meetings
PM2.5 changes with outdoor haze
Humidity increases overnight
Records are required for several days
Nobody is available to take manual readings
The required instrument depends on whether the company needs a current reading or a historical trend.
Choosing a Temtop Air-Quality Monitor
Different Temtop air-quality monitors measure different combinations of parameters.
Before selecting a model, confirm whether the application requires:
PM2.5 only
PM2.5 and PM10
COâ‚‚
TVOC
Temperature and humidity
Multiple parameters
Portable checking
Longer-term monitoring
Models such as the Temtop M2000 2nd, LKC-1000S 2nd, M10+, M10i, C1+, S1 Up and P600 serve different monitoring needs.
Do not select a model based only on appearance or price.
The required parameters should determine the choice.
What If the Reading Is High?
An elevated reading should be investigated systematically.
Check:
Is the reading repeated?
Does another location show the same result?
Did occupancy change?
Were chemicals used?
Was a door opened?
Was production operating?
Was outdoor haze present?
Was the monitor placed near a direct source?
Did the instrument have time to respond?
Do not immediately conclude that one high reading proves a permanent building problem.
Repeat the measurement under controlled and documented conditions.
Can an Air-Quality Monitor Prove ESG Compliance?
An air-quality monitor provides measurement information.
It does not automatically prove complete ESG compliance.
The company still needs to determine:
Which parameters are relevant
What measurement method is required
How often readings should be taken
Which limits or internal targets apply
Who reviews the data
What corrective action is necessary
Whether formal professional assessment is required
Portable monitors are useful for screening, comparison and internal environmental records.
Indoor Air-Quality Monitoring Equipment Malaysia
MTM Precision supplies air-quality and environmental monitoring instruments for:
Factories
Offices
Warehouses
Laboratories
Schools
Facilities teams
HVAC inspection
Haze monitoring
ESG environmental records
Customers should provide the intended location, required parameters and whether portable or continuous monitoring is needed.
Contact MTM Precision
MTM Precision Sdn Bhd
Showroom & Service Centre: No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Contact MTM Precision for suitable indoor air-quality monitoring equipment for ESG workplace records in Malaysia.
04 Oct 2026