Which Gases Should Factories Monitor for ESG Workplace Safety Malaysia?
Which Gases Should Factories Monitor for ESG Workplace Safety Malaysia?
When a factory wants to improve ESG workplace safety, purchasing a gas detector without identifying the actual hazard is not enough.
Different detectors are designed for different gases.
A standard four-gas detector may be suitable for some confined-space applications, but it cannot detect every toxic gas, refrigerant or volatile chemical.
Before choosing an instrument, ask:
What gas could be present?
Where could it accumulate?
Why does it need to be measured?
Is the detector for personal protection, area monitoring or leak investigation?
1. Oxygen — O₂
Oxygen monitoring is important in areas where normal air may be displaced or affected by chemical and biological processes.
Possible applications include:
Confined spaces
Tanks
Pits
Sewers
Process vessels
Enclosed plant rooms
Nitrogen-use areas
Wastewater facilities
The concern may be:
Oxygen deficiency
Oxygen enrichment
An oxygen detector does not identify which gas displaced the oxygen.
If nitrogen or another gas enters an enclosed area, the oxygen reading may fall even though the detector does not directly measure that gas.
Oxygen measurement should form part of an approved safety procedure rather than being used as the only control.
2. Combustible Gas — LEL
A combustible-gas detector is used to identify potentially flammable gas or vapour conditions.
Possible applications include:
Fuel storage
Gas-cylinder areas
Boiler rooms
Chemical-processing areas
Pipelines
Valves
Tanks
Maintenance work
Confined spaces
The reading may be displayed as a percentage of the Lower Explosive Limit — %LEL.
This does not mean the detector identifies every combustible substance individually.
Sensor response can differ depending on the gas, calibration gas and instrument design.
Before use, confirm whether the detector and sensor are suitable for the expected combustible gas.
3. Carbon Monoxide — CO
Carbon monoxide may be associated with incomplete combustion.
Potential sources include:
Engines
Generators
Boilers
Furnaces
Vehicles
Combustion equipment
Enclosed parking or loading areas
CO is different from CO₂.
CO → Carbon monoxide
CO₂ → Carbon dioxide
A detector designed for CO should not be assumed to measure CO₂, and a CO₂ monitor does not replace a CO safety detector.
Choose the sensor according to the required gas.
4. Hydrogen Sulphide — H₂S
Hydrogen sulphide may be relevant in:
Sewers
Wastewater treatment
Pits
Drains
Tanks
Organic decomposition areas
Oil and gas applications
Certain industrial processes
H₂S can be hazardous even when workers believe they can smell it.
Odour should not be used as the measurement method.
A suitable H₂S detector is required where the gas hazard has been identified.
5. Ammonia — NH₃
Ammonia monitoring may be relevant to:
Refrigeration systems
Fertiliser operations
Chemical storage
Food-processing facilities
Cold-storage plants
Wastewater applications
Certain production processes
A standard four-gas detector does not normally include an NH₃ sensor unless it is specifically configured for ammonia.
If the application involves ammonia, confirm:
Sensor type
Measurement range
Sampling method
Expected concentration
Operating environment
Do not confuse NH₃ ammonia with nitrogen gas.
6. Sulphur Dioxide — SO₂
Sulphur dioxide may be relevant to selected industrial and chemical applications.
Possible locations include:
Chemical-processing areas
Combustion-related processes
Gas storage
Manufacturing operations using sulphur compounds
Environmental investigation
An SO₂ detector must have a sensor intended for sulphur dioxide.
Do not assume that a general gas-leak detector or four-gas detector includes SO₂ measurement.
7. Carbon Dioxide — CO₂
CO₂ monitoring can be used for different purposes.
Possible applications include:
Indoor ventilation assessment
Occupied rooms
Food and beverage processes
Fermentation areas
Gas-cylinder storage
Laboratories
Enclosed work areas
For offices and meeting rooms, CO₂ may be monitored as an indicator of changing occupancy and ventilation conditions.
Industrial CO₂ hazards may require a detector and alarm arrangement designed for safety monitoring.
A consumer indoor air-quality monitor should not automatically be treated as a substitute for an industrial safety system.
8. Volatile Organic Compounds — VOC or TVOC
Volatile compounds may be associated with:
Paint
Adhesive
Solvent
Ink
Coating materials
Cleaning chemicals
Fuel
Manufacturing processes
A TVOC monitor provides a broad indication of total volatile organic compounds.
It normally does not identify the exact substance.
If a company needs to measure a specific VOC, it may require a dedicated detector, suitable sensor or recognised sampling method.
The terms should not be treated as identical:
TVOC → Combined indication of multiple volatile compounds
Specific VOC → A particular chemical that may require targeted measurement
9. Refrigerant Gas
Refrigerant leak detection may be relevant to:
Air-conditioning systems
Chillers
Cold rooms
Refrigeration plants
HVAC maintenance
Food-storage facilities
Refrigerants differ.
Before choosing a leak detector, confirm:
Refrigerant type
Equipment being inspected
Expected leakage location
Required sensitivity
Working environment
A combustible-gas detector should not automatically be used as a refrigerant detector.
The sensor and instrument must be suitable for the target refrigerant.
10. Formaldehyde — HCHO
Formaldehyde monitoring may be relevant to:
Furniture
Wood products
Adhesives
Renovated rooms
Building materials
Selected manufacturing processes
A general TVOC reading does not provide the same information as a dedicated HCHO measurement.
If formaldehyde is the target parameter, select an instrument or sensor intended for HCHO.
The measurement purpose should also be clear:
General screening
or
Formal workplace or environmental assessment
These may require different equipment and procedures.
Single-Gas or Multi-Gas Detector?
A single-gas detector is designed around one target gas.
Examples include:
CO
H₂S
O₂
NH₃
SO₂
A multi-gas detector measures several gases in one instrument.
A common configuration may include:
O₂
CO
H₂S
Combustible gas
The correct choice depends on the hazard.
Choose a Single-Gas Detector When:
One specific gas is the main concern
Workers require dedicated personal monitoring
The application does not require several sensors
A simpler instrument is preferred
Choose a Multi-Gas Detector When:
Several gas hazards may exist
Confined-space checking is required
Maintenance teams work in changing environments
One instrument must display multiple readings
Do not select a multi-gas detector only because it has more sensors.
Every sensor should be relevant to the actual application.
Diffusion or Pump-Sampling Detector?
A diffusion detector measures gas as it reaches the sensor naturally.
A pump-sampling detector draws a sample through tubing or a probe.
Diffusion Detector
Suitable for:
Personal monitoring
General area exposure
Wearing during work
Applications where the detector is located directly in the atmosphere being checked
Pump-Sampling Detector
Useful for:
Remote sampling
Checking a space before entry
Drawing gas from a tank or pit
Checking through tubing
Investigating difficult-to-reach locations
A pump detector does not remove the need for a safe sampling procedure.
Tubing material, tubing length, gas type and sampling time may affect the response.
Where Should Gas Measurements Be Taken?
Measurement locations depend on:
Gas density
Ventilation
Process layout
Leakage source
Worker location
Confined-space geometry
Sampling method
Possible inspection points include:
Valves
Flanges
Regulators
Connectors
Pipe joints
Gas-cylinder connections
Hoses
Storage areas
Process equipment
Low or enclosed areas
Do not choose a measurement height or detector location without considering the target gas and application.
Create a Gas-Detection Record
For ESG workplace-safety records, include:
Date
Time
Location
Work activity
Target gas
Detector model
Detector identification
Measurement result
Alarm event
Operator
Corrective action
For example:
LocationTarget GasApplicationObservationConfined SpaceO₂, CO, H₂S, LELPre-entry checkFollow site procedureRefrigeration AreaNH₃Leak investigationConfirm sensor suitabilityGenerator RoomCOCombustion-related checkNote generator conditionChemical StoreSpecific gasArea monitoringIdentify stored chemicalsMeeting RoomCO₂Ventilation observationRecord occupancy
Do not combine readings from different gases under one general description such as “air reading.”
Bump Test and Calibration
A gas detector should not be treated as reliable simply because the display turns on.
Depending on the manufacturer’s instructions and site procedures, detector management may include:
Visual inspection
Battery checking
Sensor status checking
Bump testing
Calibration
Alarm verification
Record keeping
Sensor replacement
A bump test checks whether the sensors and alarms respond when exposed to test gas.
Calibration adjusts or verifies the measurement response according to the applicable procedure.
They are not the same process.
Follow the detector manufacturer’s instructions and the company’s safety requirements.
Can Gas-Detector Readings Support ESG Records?
Yes, gas-detection records may support the social and safety aspects of ESG by documenting:
Hazard identification
Workplace monitoring
Confined-space procedures
Preventive checks
Alarm events
Corrective actions
Equipment management
However, purchasing a detector alone does not create a complete safety programme.
The company must also establish:
Risk assessment
Training
Measurement procedures
Alarm response
Maintenance
Calibration
Record retention
Emergency action
Gas Detection Equipment Malaysia
MTM Precision supplies portable gas-detection equipment for Malaysian factories, facilities teams, contractors and maintenance personnel.
Available categories include:
Single-gas detectors
Multi-gas detectors
Diffusion detectors
Pump-sampling detectors
Combustible-gas leak detectors
Selected environmental gas monitors
Suitable options may include models from OTYWELL, Wintact and Benetech, depending on the required gas and application.
Before requesting a quotation, provide the target gas, application, expected range, sampling method and working environment.
Contact MTM Precision
MTM Precision Sdn Bhd
Showroom & Service Centre: No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Contact MTM Precision for suitable gas-detection equipment for ESG workplace safety in Malaysia.
04 Oct 2026