Can FNIRSI DSO-152 Plus Measure Power Supply Ripple? Oscilloscope Guide Malaysia
Can FNIRSI DSO-152 Plus Measure Power Supply Ripple? Oscilloscope Guide Malaysia
Can you use the FNIRSI DSO-152 Plus Mini Digital Oscilloscope to check power-supply ripple?
For suitable low-voltage electronic circuits, an oscilloscope can help you observe whether a DC supply contains unwanted AC variation or repetitive noise.
This can be useful when troubleshooting:
Arduino boards
Microcontroller circuits
Low-voltage power supplies
Audio circuits
Electronic control boards
DC regulator outputs
However, ripple measurement requires more care than simply checking DC voltage.
The waveform may be small compared with the DC supply level, and incorrect probe technique can make the ripple appear much larger than it really is.
What Is Power Supply Ripple?
An ideal DC power supply would produce a perfectly constant voltage.
For example:
5.000 V
with no variation.
Real power supplies are not perfect.
The DC output may contain small periodic variations.
This unwanted AC component is commonly called:
Ripple
Depending on the circuit, you may also observe:
Switching noise
Spikes
Transient disturbances
Load-related voltage changes
An oscilloscope allows you to see these changes over time.
Why Can't a Multimeter Show Ripple Clearly?
A digital multimeter is excellent for checking the general DC voltage.
For example:
5.02 V DC
But this number does not show you exactly how the voltage changes over time.
The actual waveform might be approximately:
5.02 V DC with a small repetitive variation
A multimeter may still display a stable number.
An oscilloscope can provide additional information about the waveform riding on top of the DC supply.
Example: 5 V Power Rail
Suppose you measure a 5 V rail with a multimeter.
It reads:
5.0 V
That appears normal.
But the circuit keeps resetting.
When you observe the rail with an oscilloscope, you may discover that the voltage contains:
Ripple
Periodic dips
Noise
or
Short disturbances
This does not automatically identify the faulty component, but it provides valuable troubleshooting information.
Why Use DC Coupling First?
When troubleshooting an unknown low-voltage power rail, DC coupling can help you understand the overall signal.
You can see:
DC level
plus
Variation around the DC level
For example, you may confirm that the supply is approximately 5 V and observe whether obvious voltage dips are occurring.
This provides useful context before focusing on small ripple.
Why Is AC Coupling Useful for Ripple?
The problem with ripple measurement is that the ripple can be much smaller than the DC voltage.
Imagine:
DC supply = 5 V
while
Ripple = only a small fraction of that voltage
If you display the entire 5 V level, the small ripple may be difficult to see clearly.
With AC coupling, the steady DC component can be blocked from the display so that you can focus more closely on the changing component.
This can make small ripple easier to observe.
AC Coupling Does Not Make High Voltage Safe
This is extremely important.
Selecting:
AC Coupling
does not mean:
Safe for AC mains
and it does not increase the oscilloscope's voltage rating.
AC coupling is a signal-display function.
It is not electrical isolation.
Do not connect the DSO-152 Plus to mains electricity or hazardous power circuits simply because AC coupling is selected.
Start with the DC Voltage
Before looking for small ripple, first determine:
What DC voltage should be present?
For example:
3.3 V
5 V
9 V
12 V
or another circuit voltage.
Use an appropriate measurement method to confirm the basic supply level.
If the power rail itself is significantly wrong, that may be a more important problem than the ripple.
Then Look at the Ripple
Once you know the supply is within a suitable low-voltage range, you can investigate the smaller AC component.
Depending on the instrument and signal, you may need to adjust:
Voltage scale
Time base
Coupling
Trigger
The objective is to make the ripple visible without misinterpreting measurement noise.
Why Does Probe Technique Matter?
Ripple measurements can involve relatively small signals.
That means poor probe technique can become a significant source of error.
A long reference connection can pick up electrical noise.
The oscilloscope may then display a waveform that partly comes from the measurement setup rather than the power rail itself.
For better low-voltage ripple observation:
Keep the measurement connection appropriate
Use a solid reference point
Avoid unnecessary long connections
Keep away from strong noise sources where practical
Good probing technique is important.
Why Does the Ripple Change When I Move the Probe?
If the waveform changes dramatically when you move the probe cable or reference lead, investigate whether the measurement setup is picking up noise.
Nearby sources may include:
Switching power supplies
Motors
Transformers
Chargers
Digital electronics
Wireless equipment
Power cables
The displayed waveform is influenced by the entire measurement system.
Ripple vs Switching Noise
These terms are sometimes used loosely, but they do not necessarily describe exactly the same thing.
Ripple generally refers to periodic variation remaining on a DC supply.
Switching noise can include higher-frequency components and sharp disturbances produced by switching activity.
A power supply output can contain both.
An entry-level oscilloscope may reveal that unwanted variation exists, but it may not accurately reproduce every high-frequency noise component.
Can DSO-152 Plus Measure Very Small Ripple Accurately?
This depends on the amplitude, frequency, measurement setup and required accuracy.
The DSO-152 Plus is an entry-level mini oscilloscope.
It can be useful for:
Basic troubleshooting
Educational experiments
Comparing obvious differences
Observing suitable low-frequency ripple behaviour
But it should not automatically be treated as a precision power-supply ripple analyser.
For professional power-supply design or very small ripple measurements, more capable test equipment may be required.
Example: Linear Regulator Output
Suppose a low-voltage circuit uses a regulator.
The output should provide stable DC power.
You can check:
DC voltage
then
Ripple behaviour
If the supply becomes unstable when the circuit is loaded, the oscilloscope may reveal a changing waveform that is not obvious from a single multimeter reading.
Possible causes require further investigation and may include:
Input supply problem
Regulator problem
Capacitor problem
Load problem
Poor connection
Circuit instability
The oscilloscope shows the symptom.
You still need to diagnose the cause.
Example: Bad Capacitor
A degraded capacitor in a power-supply circuit can sometimes contribute to increased ripple.
If you have a known-good board, compare:
Good board power rail
with
Faulty board power rail
under similar operating conditions.
A clear difference can help direct further troubleshooting.
Do not replace components based only on one waveform without understanding the circuit.
Example: Microcontroller Random Reset
A microcontroller-based product resets occasionally.
The multimeter shows:
5 V
and appears normal.
But the reset happens only when a motor or another load switches.
An oscilloscope may help investigate whether the supply experiences a short voltage dip during the event.
This is a good example of why waveform measurement can provide information that a normal DC reading may miss.
Use Single Trigger for Occasional Events
If the power disturbance occurs only once or occasionally, a continuous waveform display may not be enough.
A suitable Single Trigger setup may help capture an event such as:
Startup
Button activation
Load switching
Circuit reset
However, the event must be within the DSO-152 Plus measurement capability, and the trigger must be configured appropriately.
Compare No Load and Load Conditions
Power-supply behaviour can change with load.
For suitable low-voltage circuits, you may compare the waveform under:
Low load
and
Normal operating load
If ripple or voltage instability increases significantly when the load changes, this provides additional diagnostic information.
Make sure any loading method is appropriate for the power supply.
Compare Input and Output
In some low-voltage regulator circuits, comparing behaviour before and after the regulator can help.
For example:
Input supply looks stable
but
Output becomes unstable
This directs attention toward a different area than:
Input already unstable
and
Output follows the same problem
Signal tracing principles apply to power rails as well as normal electronic signals.
Why Does the Ripple Look Larger Than Expected?
Possible causes include:
Actual excessive ripple
Incorrect voltage scale
Poor probe connection
Noise pickup
Long reference lead
Incorrect measurement point
Instrument noise
Circuit switching noise
Do not assume every small fluctuation on the screen originates from the power supply itself.
Why Does Ripple Change with Time Base?
Different time-base settings reveal different parts of the waveform.
A slower time base may make low-frequency variation easier to see.
A faster time base may reveal more detail around individual disturbances.
However, as signals become faster, the oscilloscope's bandwidth and sampling limitations become increasingly important.
Interpret the waveform according to the instrument's capability.
Can You Measure USB Power Ripple?
A suitable low-voltage USB power rail can be investigated with appropriate test equipment.
But be careful about how the measurement is connected.
USB systems can involve:
Power
Ground
Data lines
and modern charging systems may operate at different negotiated voltages.
Do not randomly probe USB connectors without identifying the correct pins and expected voltage.
For dedicated USB troubleshooting, a USB tester may also provide useful information.
Can You Measure a 12 V DC Adapter?
A 12 V label alone does not answer whether a measurement is appropriate.
You need to know:
Actual voltage
Circuit reference
Adapter topology
Whether the output is isolated
Probe and instrument ratings
Where you intend to measure
For basic low-voltage DC output checking, an oscilloscope may be useful when used correctly.
Do not extend this advice to the adapter's mains input or primary side.
Do Not Probe the Primary Side of a Power Supply Casually
This is one of the most important safety points.
A switching power supply may contain a low-voltage output side and a hazardous mains-connected primary side.
These are completely different measurement environments.
The DSO-152 Plus should not be casually connected to:
AC mains
SMPS primary circuits
High-voltage DC buses
Inverters
Industrial motor drives
Unknown floating high-voltage circuits
Professional measurements in these areas can require specialised probes, isolation strategies, suitable oscilloscope ratings and trained personnel.
Is DSO-152 Plus Good for Power Supply Troubleshooting?
For suitable low-voltage electronics, it can help answer basic questions such as:
Is the DC supply stable?
Is obvious ripple present?
Does the voltage dip when a load switches?
Does the waveform differ from a working PCB?
Does the power rail change during a fault?
These are valuable troubleshooting questions.
But the DSO-152 Plus should not be treated as a substitute for higher-performance equipment when precise ripple or high-frequency noise analysis is required.
DSO-152 Plus vs Multimeter for Power Supply Testing
A practical workflow is to use both.
Use the multimeter to check:
Basic DC voltage
Then use the oscilloscope when you need to investigate:
Ripple
Noise
Voltage dips
Startup behaviour
Load-related changes
Intermittent disturbances
The instruments complement each other.
Quick Power Supply Ripple Checklist
Before checking ripple with the FNIRSI DSO-152 Plus, ask:
1. What DC voltage should be present?
2. Is this a suitable low-voltage circuit?
3. Where is the correct reference point?
4. Is the probe configured correctly?
5. Have you checked the DC level first?
6. Would AC coupling help reveal the changing component?
7. Is the probe connection picking up noise?
8. Does the waveform change under load?
9. Can you compare with a working board?
10. Is the ripple small or fast enough to require better equipment?
These questions can prevent misleading conclusions.
FNIRSI DSO-152 Plus Power Supply Ripple Measurement Malaysia
The FNIRSI DSO-152 Plus can be useful for basic investigation of power-supply ripple and voltage instability in suitable low-voltage electronics.
It is especially useful when a multimeter shows an apparently normal DC voltage but the circuit still experiences:
Resets
Noise
Intermittent operation
Load-related instability
Unexpected behaviour
For small or high-frequency ripple measurements, remember that probe technique and oscilloscope performance matter.
And for mains-connected or high-voltage power electronics, use properly rated professional measurement equipment and appropriate safety procedures.
MTM Precision supplies FNIRSI oscilloscopes and electronic test instruments in Malaysia.
If you are troubleshooting a power-supply waveform, send us:
A photo or short video of the oscilloscope display
Equipment or PCB model
Expected DC voltage
Measurement point
Probe setting
Description of the fault
through WhatsApp.
We can help determine whether the DSO-152 Plus is suitable or whether a higher-performance oscilloscope or another test instrument would be more appropriate.
MTM Precision Sdn Bhd
Showroom & Service Centre:
No. 29-1 & 2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Supplying FNIRSI and electronic test instruments throughout Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.
06 Oct 2026