You check a motor-control PCB with the FNIRSI DSO-152 Plus Mini Digital Oscilloscope.
The PWM signal is present.
The frequency appears reasonable.
The duty cycle changes when you adjust the control.
But the motor still does not run.
Does this mean the motor is faulty?
Not necessarily.
Finding PWM is only one part of the motor-control system.
A typical control path may involve:
Controller → PWM → Driver → Power Stage → Motor
The PWM signal can be perfectly normal while a fault elsewhere prevents the motor from operating.
The next step is to determine:
Where does the control stop becoming effective?
PWM Present Is Good Information
Finding PWM is already useful.
It suggests that at least part of the control circuit is active.
For example, the microcontroller may be:
Powered
Running its program
Receiving a command
and
Generating a control output
This helps narrow the troubleshooting area.
But it does not prove that the complete motor-control circuit is working.
Understand the Control Path
Before measuring further, identify the basic circuit structure.
A simplified system may look like:
Microcontroller
↓
PWM Signal
↓
Gate/Driver Circuit
↓
Power Switching Device
↓
Motor
More complex systems may also include:
Enable signal
Direction control
Current sensing
Feedback
Protection circuit
Speed feedback
Temperature protection
Power-stage supply
A missing condition anywhere in this chain can prevent operation.
Step 1: Confirm the PWM Is Really Correct
Do not stop at:
“I can see pulses.”
Check whether the waveform makes sense.
Look at:
Frequency
Duty cycle
HIGH level
LOW level
Stability
Whether duty cycle changes with the command
Suppose the motor-speed setting changes from low to high.
You may expect the PWM duty cycle to change accordingly.
If the waveform never changes, the control system may not be responding correctly even though PWM is technically present.
PWM Frequency vs Duty Cycle
These are different measurements.
Frequency tells you how often the PWM cycle repeats.
Duty cycle tells you how much of each cycle is ON.
For example:
20% duty cycle
and
80% duty cycle
can operate at the same frequency.
In many control systems, changing the duty cycle changes the effective motor command.
Step 2: Check the Motor Power Supply
The control signal can be present while the motor power supply is missing.
For example:
Controller supply = 5 V
but
Motor supply = 24 V
If the 5 V control circuit is working but the 24 V motor supply is absent, the oscilloscope may show perfect PWM while the motor remains stationary.
Check all relevant supply rails.
Don't Assume One Power Rail Supplies Everything
Motor-control boards often contain separate power domains.
For example:
Logic power
Driver power
Motor power
Finding one correct voltage does not confirm all of them.
Check the circuit documentation or PCB layout where available.
Step 3: Check the Enable Signal
Many motor drivers require an enable condition.
The driver may receive:
Power
and
PWM
but still produce no motor output because:
Enable = OFF
The enable line may be controlled by:
Microcontroller
Safety circuit
Protection circuit
Interlock
External control
Before replacing the driver, check whether it is actually being told to operate.
Step 4: Check Direction or Control Inputs
Some motor-control systems use additional logic inputs.
For example:
PWM
Enable
Direction
The correct PWM signal alone may not be enough.
If another required control input is missing or in the wrong state, the motor may remain stopped.
Step 5: Check Whether PWM Reaches the Driver
Suppose PWM is present directly at the microcontroller output.
Now check the appropriate driver input.
If the waveform is:
Present at controller
but
Missing at driver
investigate the components between those points.
Possible areas include:
Resistor
Buffer
Optocoupler
Connector
PCB track
Logic gate
Level-shifting circuit
The controller may be working perfectly while the signal path is damaged.
Step 6: Check the Driver Power
A driver can receive the correct PWM input but still do nothing if its own supply is missing.
Check the relevant driver power according to the circuit design.
A common troubleshooting mistake is replacing the driver IC before confirming that it has:
Correct power
Correct control input
Correct enable condition
Step 7: Determine Whether the Driver Produces an Output
If the driver receives:
Power
PWM
and
Enable
but the expected output is missing, the investigation becomes more focused.
Possible causes may include:
Driver fault
Protection condition
Incorrect control state
Surrounding component fault
Output-stage problem
At this point, circuit documentation becomes increasingly valuable.
Driver Output Is Not Always the Same as Microcontroller PWM
Do not assume every stage should show exactly the same waveform.
A driver may:
Invert the signal
Change voltage level
Drive complementary outputs
Introduce dead time
Control a bridge
Provide gate-drive signals
Therefore, you need to understand what waveform is expected at the point being measured.
Step 8: Check the Power Switching Stage
Motor-control circuits often use power devices such as MOSFETs or other switching components.
The control section may work while the power stage fails.
Possible symptoms include:
PWM at driver input
but
No effective motor voltage/current
Troubleshooting the power stage requires greater care because voltages, currents and switching transients can be significantly higher than in the logic section.
Do Not Randomly Probe H-Bridge Nodes
An H-bridge can contain rapidly switching nodes and measurement conditions that are not suitable for casual probing with an entry-level oscilloscope.
Do not assume:
Motor supply is only 12 V or 24 V, therefore every point is safe to measure.
Switching topology, reference conditions and transients matter.
Use appropriate measurement equipment and techniques for power-stage measurements.
Step 9: Check the Motor Itself
If the control and power stages appear to be operating, investigate the motor.
Possible motor-related problems include:
Open winding
Mechanical jam
Worn brushes where applicable
Connector fault
Cable fault
Internal protection
Bearing problem
Excessive load
The oscilloscope is only one part of the troubleshooting process.
A multimeter and other suitable tests may also be required.
Example: PWM Changes but Motor Never Starts
Suppose:
20% command → PWM visible
50% command → Duty cycle increases
80% command → Duty cycle increases again
This suggests the controller is responding to the speed command.
But the motor remains stopped.
The next questions become:
Is motor power available?
Is the driver enabled?
Does PWM reach the driver?
Is the driver producing the expected control?
Is the power stage operating?
Is the motor electrically and mechanically healthy?
This is much more useful than immediately replacing the controller.
Example: PWM at Controller but Not at Driver
You measure:
Microcontroller output = Good PWM
Then:
Driver input = No PWM
Now the fault is likely somewhere between those test points.
Investigate:
PCB track
Resistor
Connector
Buffer
Optocoupler
or another intermediate component.
This is the advantage of signal tracing.
Example: PWM Reaches Driver but Motor Does Not Run
Now suppose:
Controller PWM = Good
Driver input = Good
Driver power = Present
but the motor still does not operate.
The troubleshooting focus shifts toward:
Enable/control conditions
Driver output
Power switching stage
Motor power
Motor and wiring
You have already eliminated several earlier stages.
What If the Motor Starts but Has No Speed Control?
Suppose the motor runs, but changing the control does not change the speed.
Check whether the PWM duty cycle changes.
If:
Command changes
but
PWM duty cycle does not
investigate the control side.
If:
PWM duty cycle changes correctly
but
Motor behaviour does not change
investigate downstream stages.
This distinction can save significant troubleshooting time.
What If the Motor Runs Only at Full Speed?
A motor that operates only at full speed may indicate a different fault from a motor that does not run at all.
Check:
PWM waveform
Duty-cycle response
Driver operation
Control input
Power-stage behaviour
Feedback system
Do not assume the PWM controller is faulty until the actual waveform has been checked.
What If the PWM Is Unstable?
If the PWM itself changes unexpectedly, investigate upstream conditions.
Possible causes include:
Power instability
Changing sensor input
Controller reset
Protection logic
Incorrect command
Software behaviour
Noise
The motor-control problem may begin before the driver stage.
Check the Power Rail During Motor Startup
Motors can create a significant load during startup.
A supply that appears normal when the motor is stopped may drop when the motor attempts to start.
For suitable low-voltage circuits, an oscilloscope may help investigate whether the power rail experiences a voltage dip during the startup event.
This can be especially useful when the system:
Starts and resets
Tries to start repeatedly
Operates intermittently
Use Single Trigger for Startup Events
If the problem occurs only when the motor is commanded to start, a suitable Single Trigger setup may help capture the event.
You may investigate:
Control pulse
Enable event
Suitable low-voltage supply behaviour
However, the event must remain within the DSO-152 Plus measurement capability.
Feedback Can Prevent Motor Operation
Some systems monitor:
Motor current
Motor speed
Position
Temperature
Fault status
If the feedback indicates an unsafe or abnormal condition, the controller may disable the motor.
Therefore, good PWM at one point does not prove that the complete control logic is satisfied.
PWM Control and Tachometer Feedback Are Different
This is particularly important with multi-wire fans.
A fan may have separate connections for:
Power
Ground
PWM control
Tachometer feedback
Do not confuse the tachometer waveform with the PWM command.
They serve different purposes and can have different frequencies.
Identify the wire or test point before interpreting the waveform.
Use a Multimeter Together with the Oscilloscope
The oscilloscope should not replace the multimeter.
Use a multimeter for suitable checks such as:
DC supply voltage
Continuity
Resistance
Motor winding checks
Then use the oscilloscope for:
PWM
Pulses
Control timing
Intermittent events
Dynamic supply behaviour
Together, they provide a more complete picture.
Is DSO-152 Plus Suitable for Motor-Control Troubleshooting?
For suitable low-voltage control-side signals, the DSO-152 Plus can help answer questions such as:
Is PWM present?
Does duty cycle change?
Does the control signal reach the driver?
Is an intermittent pulse present?
Does a suitable low-voltage rail dip during operation?
These are useful diagnostic questions.
When Do You Need a Better Oscilloscope?
Consider more capable equipment when you need:
Two-channel comparison
Fast switching analysis
Detailed gate-drive measurements
High-frequency signals
Power-electronics troubleshooting
Differential measurements
Professional motor-drive analysis
A dual-channel or higher-performance oscilloscope can be much more appropriate for advanced motor-control work.
Industrial Motor Drives Require Different Equipment
Do not extend basic PCB PWM troubleshooting methods directly to industrial motor drives.
Industrial systems may contain:
High-voltage DC buses
Three-phase power
High-energy switching
IGBT or MOSFET bridges
Dangerous transient voltages
Non-ground-referenced switching nodes
The DSO-152 Plus is not a substitute for properly rated professional power-electronics measurement equipment.
Quick PWM Present but Motor Not Running Checklist
If you can see PWM but the motor does not run, check:
1. Is the PWM frequency reasonable?
2. Does duty cycle respond to the command?
3. Is motor power present?
4. Is driver power present?
5. Is the enable condition correct?
6. Does PWM reach the driver?
7. Are additional control inputs required?
8. Is the driver producing the expected output?
9. Is the power stage operating correctly?
10. Is the motor and wiring healthy?
This helps divide the system into logical troubleshooting stages.
FNIRSI DSO-152 Plus Motor PWM Troubleshooting Malaysia
Finding PWM is not the end of motor troubleshooting.
It is the beginning of a more focused diagnosis.
If the PWM signal is present but the motor does not run, trace the control path:
PWM → Driver → Power Stage → Motor
while also checking:
Power
Enable
Protection
and
Feedback
For suitable low-voltage electronics, the FNIRSI DSO-152 Plus can be a useful tool for basic PWM and control-signal troubleshooting.
MTM Precision supplies FNIRSI oscilloscopes and electronic test instruments in Malaysia.
If you are troubleshooting a motor controller, fan controller or PWM circuit, send us:
A photo of the PCB
Motor or equipment model
Motor supply voltage
Photo or video of the waveform
Expected PWM frequency if known
Description of the fault
through WhatsApp.
We can help determine whether the DSO-152 Plus is suitable or whether a dual-channel or higher-performance oscilloscope is more appropriate.
MTM Precision Sdn Bhd
Showroom & Service Centre:
No. 29-1 & 2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Supplying FNIRSI and electronic test instruments throughout Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.
06 Oct 2026