Can FNIRSI DSO-152 Plus Test UART, I2C and SPI Signals Malaysia?
Can FNIRSI DSO-152 Plus Test UART, I2C and SPI Signals Malaysia?
Can the FNIRSI DSO-152 Plus Mini Digital Oscilloscope be used to test UART, I2C or SPI signals?
For suitable lower-frequency digital electronics, it can help answer basic electrical questions such as:
Is there signal activity?
Is the line stuck HIGH or LOW?
Are pulses being generated?
Does communication start when a command is sent?
However, the DSO-152 Plus is an oscilloscope, not a full protocol analyser.
It is important to understand what it can show and when you need a logic analyser or higher-performance oscilloscope instead.
What Is the Difference Between Seeing a Signal and Decoding Data?
Suppose two devices communicate using UART.
An oscilloscope may show:
Voltage transitions
Pulse timing
Signal activity
But this does not automatically tell you:
What characters were transmitted
What command was sent
Whether the packet is correct
That requires protocol interpretation or decoding.
This distinction applies to UART, I2C and SPI.
What Can DSO-152 Plus Tell You?
For suitable signals within its practical measurement capability, the DSO-152 Plus may help answer:
Is the communication line active?
Is there a pulse train?
Is the signal reaching the next circuit stage?
Is the line always HIGH?
Is the line always LOW?
Does activity appear when the device starts?
These are valuable troubleshooting questions.
What Can't It Replace?
The DSO-152 Plus should not be treated as a replacement for a dedicated logic analyser when you need:
Protocol decoding
Long data capture
Multiple digital channels
Packet analysis
Detailed timing correlation
Automatic UART decoding
I2C address decoding
SPI data decoding
For those applications, another instrument may be more appropriate.
Testing UART with FNIRSI DSO-152 Plus
UART is commonly used in:
Microcontrollers
Arduino
ESP32
Embedded electronics
GPS modules
Sensors
Development boards
Industrial control electronics
Typical UART lines include:
TX
RX
and a common reference.
What Can You Check on UART?
Suppose two boards are supposed to communicate but nothing happens.
You can start by checking the TX line.
Ask:
Is there activity when data should be transmitted?
If you see pulses, the transmitting device is at least generating electrical activity.
If the line remains completely inactive, investigate the transmitting side.
Example: Arduino TX Signal
Suppose an Arduino program sends serial data every second.
You probe the TX line.
You should expect to see bursts of digital activity.
If you see:
Repeated pulse bursts
that indicates transmission activity.
If you see:
Only a constant level
then investigate:
Program operation
TX pin selection
Baud configuration
Controller reset
Power
Wiring
The oscilloscope helps confirm whether something is happening electrically.
Can DSO-152 Plus Read the UART Message?
Not in the same convenient way as a protocol-decoding logic analyser.
You may be able to inspect basic timing on suitable slower signals, but manually interpreting complete serial data is inefficient.
If your question is:
“Is TX active?”
an oscilloscope can be useful.
If your question is:
“Exactly what bytes are being transmitted?”
use a more suitable protocol-analysis tool.
TX Works but RX Does Not
Suppose:
TX at Controller A = Activity
but
RX at Controller B = No activity
Now investigate the signal path between them.
Possible causes include:
Broken PCB track
Connector problem
Wrong wiring
Level-shifting circuit
Buffer fault
Poor connection
This is a good example of basic signal tracing.
Testing I2C with FNIRSI DSO-152 Plus
I2C commonly uses two lines:
SCL – Clock
SDA – Data
It is widely used for communication between microcontrollers and devices such as:
Sensors
Displays
EEPROM
RTC modules
ADC/DAC devices
Peripheral ICs
What Can You Check on I2C?
An oscilloscope may help determine whether:
Clock activity exists
Data activity exists
A line is stuck
Communication begins during startup
For basic troubleshooting, these observations can already be useful.
Example: Sensor Not Detected
Suppose a microcontroller cannot detect an I2C sensor.
First check:
Power to sensor
Then inspect:
SCL
and
SDA
If both lines show no activity when communication should occur, investigate the controller and software side.
If clock activity is present but the data behaviour appears abnormal, further protocol-level analysis may be required.
Why Are Pull-Up Resistors Important for I2C?
I2C commonly relies on pull-up resistors.
Problems involving:
Missing pull-up
Incorrect resistor value
Short circuit
Faulty device pulling the line down
can affect communication.
An oscilloscope can help show whether a line reaches the expected logic levels and how the transitions behave.
However, interpreting these details accurately requires appropriate oscilloscope performance and understanding of the circuit.
I2C Line Stuck LOW
A common fault symptom is an I2C line that remains LOW.
Possible causes may include:
Short circuit
Faulty peripheral
Controller condition
Wiring problem
Circuit fault
If the line should be communicating but never changes state, the oscilloscope provides useful evidence for further troubleshooting.
Can DSO-152 Plus Decode the I2C Address?
The DSO-152 Plus should not be purchased specifically for automatic I2C protocol decoding.
If you need to know:
Device address
ACK/NACK
Register data
Complete communication sequence
a logic analyser or oscilloscope with suitable protocol-decoding capability is a better choice.
Testing SPI with FNIRSI DSO-152 Plus
SPI typically involves several signals, such as:
Clock
Data
Chip Select
and potentially separate transmit and receive data lines.
This immediately creates a limitation for a simple single-channel oscilloscope.
Why Is Single Channel a Limitation for SPI?
With a single channel, you can inspect one signal at a time.
For example:
First check:
Clock
Then:
Data
Then:
Chip Select
This can confirm whether each line has electrical activity.
But you cannot easily observe their timing relationship simultaneously.
For SPI troubleshooting, multiple channels can be much more useful.
Example: Display Not Working
Suppose a microcontroller communicates with a display using SPI.
The display remains blank.
You may check:
Is the display powered?
Does the clock line have activity?
Does the data line have activity?
Does chip select change?
If there is no activity at all, investigate the controller side.
If all lines are active but the display still does not work, protocol configuration or the peripheral itself may require further investigation.
Why a Logic Analyser Is Better for Digital Protocols
A logic analyser is designed specifically for digital signals.
Depending on the model and software, it may provide:
Multiple channels
Long capture
UART decoding
I2C decoding
SPI decoding
Timing analysis
This makes it much easier to understand what digital devices are actually communicating.
Why an Oscilloscope Is Still Useful
A logic analyser normally focuses on whether a digital signal is interpreted as:
HIGH
or
LOW
An oscilloscope shows the actual electrical waveform.
This can reveal problems such as:
Slow rise time
Noise
Ringing
Incorrect voltage level
Distorted edges
Overshoot
Power instability
Therefore, oscilloscopes and logic analysers solve different problems.
Oscilloscope vs Logic Analyser
A useful way to think about it is:
Oscilloscope:
“What does the electrical waveform actually look like?”
Logic analyser:
“What digital information is being transmitted?”
For serious embedded-system troubleshooting, engineers may use both.
Can DSO-152 Plus Test Arduino Communication?
For suitable basic Arduino troubleshooting, yes.
You may use it to check whether there is electrical activity on:
UART TX
PWM
GPIO
Suitable I2C lines
Suitable SPI lines
But remember the bandwidth and sampling limitations of an entry-level oscilloscope.
It is not designed for every high-speed microcontroller signal.
Can It Test ESP32?
The same principle applies.
The ESP32 can operate with many different signal types and speeds.
The DSO-152 Plus may be useful for suitable lower-frequency signals and basic activity checks.
But do not assume it can accurately analyse every ESP32 communication interface.
For faster signals, use a more capable instrument.
Can It Test Raspberry Pi GPIO?
For suitable GPIO activity, a small oscilloscope can help answer basic questions such as:
Is the pin changing state?
Is PWM present?
Is there basic serial activity?
But advanced digital communication analysis may require more bandwidth, more channels or a logic analyser.
Why Bandwidth Matters for Digital Signals
A common misunderstanding is:
“My UART is only 115200 baud, so any oscilloscope can measure it perfectly.”
Digital signals contain fast edges.
The fundamental data rate is not the only factor that determines how accurately the waveform can be reproduced.
Bandwidth and sampling performance affect how the oscilloscope displays those edges.
This becomes increasingly important with faster digital electronics.
Sampling Rate Matters Too
The oscilloscope must take enough samples to represent the waveform.
If the signal is too fast relative to the sampling system, you may see:
Incorrect waveform shape
Missing pulses
Unstable display
Aliasing
Therefore, seeing something on the screen does not automatically mean the waveform is being reproduced accurately.
Can Triggering Help?
Yes.
For repetitive communication activity, a suitable trigger can help stabilise the waveform.
For occasional events, Single Trigger may help capture a suitable communication burst.
However, the trigger does not increase the bandwidth or sampling capability of the oscilloscope.
It only helps control when the waveform is captured or displayed.
Check Voltage Levels Before Probing
Microcontroller systems commonly use logic levels such as:
5 V
3.3 V
and sometimes lower voltages.
Know the expected voltage before connecting the probe.
Do not assume every digital interface uses the same voltage level.
Incorrect connections can damage sensitive electronics.
Common Digital Communication Troubleshooting Workflow
If two devices are not communicating, check:
1. Are both devices powered?
2. Is the reference connection correct?
3. Are the expected communication lines identified correctly?
4. Is there electrical activity?
5. Does the activity reach the receiving device?
6. Are the voltage levels reasonable?
7. Is a line stuck HIGH or LOW?
8. Is protocol decoding required?
This separates electrical problems from protocol-level problems.
Example: Communication Works on One PCB but Not Another
If you have:
Working PCB
and
Faulty PCB
compare the same communication line.
For example:
Good PCB TX = Repeated pulse activity
Faulty PCB TX = Flat line
This strongly suggests the investigation should move toward the transmitting controller or its operating conditions.
If both boards show similar activity, the problem may be elsewhere.
When DSO-152 Plus Is Enough
The DSO-152 Plus may be sufficient when you mainly need to know:
Is the line active?
Is PWM present?
Is there a pulse?
Is the signal reaching the next stage?
Is the line stuck?
Does activity appear when the device starts?
These are common electronics repair questions.
When DSO-152 Plus Is Not Enough
Use more capable equipment when you need:
Protocol decoding
High-speed digital signals
Multiple channels simultaneously
Clock-to-data timing comparison
Detailed signal-integrity analysis
Long communication capture
Professional embedded-system development
This is especially important for SPI and other multi-line interfaces.
Which FNIRSI Instrument Should You Consider Next?
If your work is mainly:
Basic electronics learning
Simple Arduino troubleshooting
PWM
Basic waveform checking
the DSO-152 Plus can be a practical starting point.
If you need more oscilloscope performance, consider a higher-performance FNIRSI model.
If you need to compare multiple signals simultaneously, a dual-channel oscilloscope can be much more useful.
If your primary objective is decoding digital communication, consider a suitable logic analyser.
Choose the instrument according to the measurement problem.
Safety Still Matters
UART, I2C and SPI are normally associated with low-voltage electronics.
But the PCB containing them may still be part of equipment connected to hazardous voltages.
Do not assume the entire board is safe because one microcontroller operates at 3.3 V.
Be especially careful with:
Mains-powered equipment
Switching power supplies
Inverters
Industrial controllers
Motor drives
Unknown power circuits
Identify the circuit and reference conditions before connecting any oscilloscope.
Quick UART, I2C and SPI Checklist
Before using the FNIRSI DSO-152 Plus on a digital communication line, ask:
1. What protocol am I checking?
2. What voltage level should I expect?
3. What is the correct reference point?
4. Is the signal within the oscilloscope's capability?
5. Do I only need to confirm activity?
6. Do I need to compare multiple lines simultaneously?
7. Do I need actual protocol decoding?
8. Would a logic analyser be more suitable?
This helps prevent choosing the wrong test instrument.
FNIRSI DSO-152 Plus for UART, I2C and SPI Malaysia
The FNIRSI DSO-152 Plus can be useful for basic digital electronics troubleshooting when the objective is to determine whether a suitable signal is electrically present.
It can help with questions such as:
“Is UART transmitting?”
“Is the I2C clock active?”
“Is there SPI clock activity?”
“Is the line stuck HIGH or LOW?”
But if the objective is:
“What exact data packet is being transmitted?”
then a protocol-capable logic analyser or more advanced test setup may be more appropriate.
MTM Precision supplies FNIRSI oscilloscopes and electronic test instruments in Malaysia.
If you are troubleshooting an Arduino, ESP32, Raspberry Pi, microcontroller or electronic PCB, send us:
A photo of the PCB
Controller or equipment model
Communication type – UART, I2C or SPI
Expected voltage
Expected frequency or data rate if known
Description of the fault
through WhatsApp.
We can help determine whether the FNIRSI DSO-152 Plus is suitable or whether you need a higher-performance oscilloscope, dual-channel instrument or logic analyser.
MTM Precision Sdn Bhd
Showroom & Service Centre:
No. 29-1 & 2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Supplying FNIRSI and electronic test instruments throughout Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.
06 Oct 2026