How to Test Sensor Output Signals with FNIRSI DSO-152 Plus Malaysia

How to Test Sensor Output Signals with FNIRSI DSO-152 Plus Malaysia

A sensor has power.

The wiring looks correct.

But the controller still shows:

No reading

Incorrect reading

Intermittent reading

or

No response

How do you determine whether the sensor is actually producing an output signal?

For suitable low-voltage electronics, an oscilloscope such as the FNIRSI DSO-152 Plus Mini Digital Oscilloscope can help you observe how a sensor output changes over time.

This is especially useful when a multimeter alone cannot clearly show:

Pulses

Rapid changes

PWM

Intermittent signals

Changing analogue outputs

The key is to understand what type of output the sensor should produce before connecting the oscilloscope.

First: What Type of Sensor Output Are You Testing?

Not every sensor produces the same type of electrical signal.

Depending on the sensor, the output may be:

DC analogue voltage

Pulse output

PWM

Frequency output

Digital HIGH/LOW

Serial communication

Before measuring, identify the expected output type.

Without this information, even a correct waveform can be misinterpreted.

Example: Analogue Voltage Sensor

Some sensors produce a voltage that changes according to the measured condition.

For example, the output may change when:

Temperature changes

Pressure changes

Position changes

Light level changes

Magnetic field changes

Distance changes

A multimeter may be enough for slowly changing signals.

But an oscilloscope can show how smoothly and quickly the voltage changes.

Example: Digital Sensor Output

A digital sensor may switch between:

LOW

and

HIGH

when a target or condition is detected.

Examples may include suitable:

Proximity sensors

Position sensors

Optical sensors

Hall-effect sensors

An oscilloscope can help confirm whether the switching actually occurs.

Example: Pulse Output Sensor

Some sensors generate pulses.

In this case, a multimeter may show an average voltage that is difficult to interpret.

An oscilloscope allows you to see:

Pulse presence

Pulse width

Frequency

Timing

This can be much more useful during troubleshooting.

Example: PWM Sensor Output

Some electronic systems use PWM to represent a changing value.

In this situation, the important information may be contained in:

Duty cycle

rather than simply the average voltage.

An oscilloscope is particularly useful because you can see the pulse pattern directly.

Step 1: Identify the Sensor Supply Voltage

Before checking the output, determine:

What voltage should power the sensor?

Depending on the design, this might be:

3.3 V

5 V

12 V

or another specified voltage.

Do not assume every sensor uses the same supply.

Step 2: Confirm the Sensor Has Power

Use an appropriate meter to verify the supply.

If the sensor does not receive the correct power, there is little value diagnosing the output first.

A missing sensor output may simply be caused by:

Missing supply

Broken wire

Connector problem

Poor ground/reference

Regulator problem

Step 3: Identify the Correct Output Wire or Test Point

Do not probe random pins.

Determine:

Power

Reference

Output

and any additional connections.

If a datasheet or wiring diagram is available, use it.

Connecting an oscilloscope to the wrong pin can produce misleading results.

Step 4: Determine the Expected Output

Before looking at the screen, ask:

What should happen when the sensor is activated?

For example:

Voltage should increase

Voltage should decrease

Output should switch HIGH

Output should switch LOW

Pulses should appear

Frequency should increase

This gives you a reference for interpreting the waveform.

Step 5: Observe the Sensor at Rest

Measure the output when the sensor is in its normal or inactive condition.

Record what you see.

For example:

Stable LOW

Stable HIGH

Fixed DC voltage

Repeated pulses

Then activate the sensor and compare.

Step 6: Activate the Sensor

Depending on the sensor, change the measured condition.

For example:

Move a target

Rotate a shaft

Move a magnet

Change light level

Change position

Apply the normal operating condition

Observe whether the waveform changes.

Example: Hall Sensor

A suitable Hall-effect sensor may respond to a magnetic field.

Depending on the sensor type, you may observe:

Digital switching

or

Changing analogue voltage

Move the magnet or target and observe the response.

If the sensor has correct power but the expected output never changes, further investigation is required.

Example: Proximity Sensor

Suppose a low-voltage proximity sensor is connected to a control PCB.

The machine reports that the sensor is not detecting a target.

Check:

Sensor power

then

Sensor output

Move the target into and out of the sensing area.

If the sensor output changes correctly but the controller does not respond, investigate the signal path after the sensor.

Sensor Works but Controller Does Not See It

This is an important troubleshooting situation.

Suppose:

Sensor output = Correct

but

Controller input = No signal

Now trace the signal.

The path may include:

Connector

Resistor

Filter

Optocoupler

Buffer

Signal-conditioning circuit

PCB track

Measure before and after each relevant stage.

The fault may not be the sensor.

Controller Input Has Signal but Reading Is Wrong

Suppose the expected signal reaches the controller.

The problem may then involve:

Signal interpretation

Calibration

Software

Reference voltage

Incorrect configuration

Another sensor input

At this stage, simply replacing the sensor may not solve the problem.

Sensor Output Is Stuck HIGH

If a sensor output remains HIGH regardless of the measured condition, investigate:

Actual sensor behaviour

Wiring

Pull-up circuit

Output configuration

Signal path

Sensor fault

Some sensor outputs require external components, so understand the circuit before diagnosing the sensor.

Sensor Output Is Stuck LOW

Similarly, a permanently LOW signal may result from:

Sensor condition

Short circuit

Missing pull-up

Faulty wiring

Incorrect power

Faulty sensor

Downstream circuit pulling the signal down

Measure at multiple points if necessary.

Sensor Output Changes at the Sensor but Not After the Connector

Suppose:

Sensor output pin = Good

but

PCB connector output = Missing

Now you have narrowed the problem significantly.

Check:

Cable

Connector

Terminal

Broken conductor

Poor contact

This is why signal tracing is so effective.

Intermittent Sensor Signal

Some sensor problems occur only occasionally.

The signal may disappear because of:

Loose connector

Vibration

Damaged cable

Temperature

Mechanical movement

Power instability

Sensor internal fault

An oscilloscope may help reveal brief interruptions that are difficult to catch with a multimeter.

Use Single Trigger for Occasional Pulses

If the sensor produces a one-time or occasional event, Single Trigger may be useful.

For example:

Object passes sensor

→ pulse occurs once.

Instead of trying to watch continuously, configure the trigger to capture a suitable event.

This can make intermittent pulse testing easier.

Check the Trigger Level

If the trigger level is outside the signal amplitude, the waveform may not stabilise or capture as expected.

For example, if a digital sensor switches between approximately:

0 V and 5 V

the trigger level should be chosen appropriately within the signal range.

Trigger settings do not increase the oscilloscope's input capability.

Check the Time Base

A sensor signal can appear completely different depending on the time scale.

If the pulses occur slowly, use a slower time base.

If the pulses are faster, use an appropriate faster time base.

The objective is to display enough of the waveform to understand the pattern.

Check the Voltage Scale

If a 3.3 V sensor signal appears tiny on the screen, adjust the vertical scale.

Similarly, if the waveform goes outside the display, use a more suitable range.

Correct scaling makes interpretation much easier.

Analogue Sensor: Look for Smooth Changes

For an analogue sensor, observe whether the output changes reasonably as the measured condition changes.

Possible abnormal behaviour includes:

Sudden jumps

Dropouts

Unexpected noise

No response

Output stuck at one level

But remember that the expected behaviour depends on the specific sensor.

Pulse Sensor: Look at Frequency

Some sensors represent speed or movement using pulse frequency.

For example, increasing rotational speed may produce pulses more frequently.

The oscilloscope can help you observe whether:

Pulses exist

and

Frequency changes with speed

This can be useful for suitable tachometer or rotational sensing applications.

PWM Sensor: Look at Duty Cycle

If the sensor uses PWM, the frequency may remain relatively constant while the duty cycle changes.

For example:

Low measurement value → lower duty cycle

Higher measurement value → higher duty cycle

The exact relationship depends on the sensor specification.

Do not assume every PWM sensor follows the same behaviour.

Can DSO-152 Plus Test Temperature Sensors?

It depends on the sensor type.

Some temperature sensors produce:

Analogue voltage

Some are:

Resistive sensors

Others communicate digitally using a protocol.

An oscilloscope is useful only when the sensor output produces an appropriate electrical waveform to observe.

For a simple resistive temperature sensor, a multimeter may be more appropriate.

Can It Test Speed Sensors?

For suitable low-voltage speed sensors that generate pulses, an oscilloscope can be very useful.

You may check:

Pulse presence

Frequency

Signal stability

Changes with speed

However, automotive and industrial sensors can use different electrical systems, so confirm the signal type and voltage first.

Can It Test Automotive Sensors?

Some low-voltage automotive sensor signals may be suitable for oscilloscope observation.

But automotive electronics can also contain:

Inductive spikes

Injector signals

Ignition systems

Alternator disturbances

Higher-voltage transients

Do not assume every automotive signal is safe for an entry-level oscilloscope.

Use appropriate automotive test equipment where necessary.

Can It Test Industrial Sensors?

Industrial sensors may use standards such as:

0–10 V

4–20 mA

Pulse outputs

Digital communication

The DSO-152 Plus is not automatically suitable for every industrial sensor.

For example, 4–20 mA is a current-loop signal and is normally approached differently from directly measuring a simple voltage-output sensor.

Understand the loop and measurement method before connecting the oscilloscope.

Sensor Communication vs Sensor Output

Modern sensors may communicate using:

UART

I2C

SPI

or other digital protocols.

An oscilloscope may confirm electrical activity.

But if you need to know:

What data is being transmitted?

What address is used?

What packet was sent?

a logic analyser or protocol-capable instrument may be more appropriate.

Compare with a Working Sensor

If you have two identical sensors, compare them under the same conditions.

For example:

Working sensor = Clean changing pulse

Suspected sensor = No output

This comparison can be more useful than guessing what the waveform should look like.

Compare with a Working PCB

You can also compare:

Good machine

and

Faulty machine

Measure the same sensor signal at the same test point.

If the waveforms are different, continue tracing until you identify where the difference begins.

Don't Replace the Sensor Too Quickly

A machine reports:

Sensor Error

That does not automatically mean:

Sensor is faulty.

The actual problem may be:

Power supply

Cable

Connector

Signal-conditioning circuit

Controller input

Configuration

Mechanical target

Software

Test systematically before replacing parts.

DSO-152 Plus vs Multimeter for Sensor Testing

Use the multimeter for suitable checks such as:

Supply voltage

Resistance

Continuity

Slow DC output

Use the oscilloscope when you need to see:

Pulses

PWM

Frequency

Intermittent signals

Fast voltage changes

Waveform shape

Often, using both instruments provides the fastest diagnosis.

When Is DSO-152 Plus Suitable?

For suitable low-voltage sensor circuits, the DSO-152 Plus can help answer:

Does the sensor have an output?

Does the output change?

Is there a pulse?

Is PWM present?

Does frequency change?

Does the signal reach the controller?

These are excellent basic troubleshooting questions.

When Do You Need Better Equipment?

Consider a more capable oscilloscope or specialised instrument for:

High-frequency sensor signals

Very small analogue signals

Multiple signals simultaneously

Detailed digital protocol analysis

Automotive ignition-related measurements

Industrial high-voltage systems

Precision sensor development

Choose the test instrument according to the actual signal.

Safety Before Measuring a Sensor

Do not assume a circuit is safe simply because it contains a sensor.

The sensor may be installed in equipment containing:

Mains voltage

High-voltage power supplies

Industrial drives

Inverters

High-energy motor circuits

Identify the test point, expected voltage and circuit reference before connecting the oscilloscope.

Quick Sensor Troubleshooting Checklist

If a sensor appears not to work, check:

1. What type of sensor is it?

2. What supply voltage should it receive?

3. Is the supply present?

4. What output type should it produce?

5. What should happen when the sensor is activated?

6. Does the output change at the sensor?

7. Does the signal reach the PCB?

8. Does the signal reach the controller?

9. Is the signal intermittent?

10. Do you need waveform viewing or protocol decoding?

This helps separate a real sensor fault from a wiring or controller problem.

FNIRSI DSO-152 Plus Sensor Signal Testing Malaysia

The FNIRSI DSO-152 Plus can be a useful entry-level oscilloscope for troubleshooting suitable low-voltage sensor outputs.

Instead of immediately asking:

“Is the sensor bad?”

use a systematic approach:

Power → Sensor Output → Wiring → Signal Conditioning → Controller Input

This can help identify whether the problem is actually in the sensor or somewhere else in the signal path.

MTM Precision supplies FNIRSI oscilloscopes and electronic test instruments in Malaysia.

If you need to check a sensor signal, send us:

A photo of the sensor

Sensor model

Photo of the PCB or controller

Supply voltage

Expected output type if known

Photo or video of the waveform

through WhatsApp.

We can help determine whether the FNIRSI DSO-152 Plus is suitable or whether another oscilloscope, multimeter, signal analyser or specialised test instrument is more appropriate.

MTM Precision Sdn Bhd

Showroom & Service Centre:
No. 29-1 & 2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.

Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my

Supplying FNIRSI and electronic test instruments throughout Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.

06 Oct 2026