How to Test Sensor Output Signals with FNIRSI DSO-152 Plus Malaysia
How to Test Sensor Output Signals with FNIRSI DSO-152 Plus Malaysia
A sensor has power.
The wiring looks correct.
But the controller still shows:
No reading
Incorrect reading
Intermittent reading
or
No response
How do you determine whether the sensor is actually producing an output signal?
For suitable low-voltage electronics, an oscilloscope such as the FNIRSI DSO-152 Plus Mini Digital Oscilloscope can help you observe how a sensor output changes over time.
This is especially useful when a multimeter alone cannot clearly show:
Pulses
Rapid changes
PWM
Intermittent signals
Changing analogue outputs
The key is to understand what type of output the sensor should produce before connecting the oscilloscope.
First: What Type of Sensor Output Are You Testing?
Not every sensor produces the same type of electrical signal.
Depending on the sensor, the output may be:
DC analogue voltage
Pulse output
PWM
Frequency output
Digital HIGH/LOW
Serial communication
Before measuring, identify the expected output type.
Without this information, even a correct waveform can be misinterpreted.
Example: Analogue Voltage Sensor
Some sensors produce a voltage that changes according to the measured condition.
For example, the output may change when:
Temperature changes
Pressure changes
Position changes
Light level changes
Magnetic field changes
Distance changes
A multimeter may be enough for slowly changing signals.
But an oscilloscope can show how smoothly and quickly the voltage changes.
Example: Digital Sensor Output
A digital sensor may switch between:
LOW
and
HIGH
when a target or condition is detected.
Examples may include suitable:
Proximity sensors
Position sensors
Optical sensors
Hall-effect sensors
An oscilloscope can help confirm whether the switching actually occurs.
Example: Pulse Output Sensor
Some sensors generate pulses.
In this case, a multimeter may show an average voltage that is difficult to interpret.
An oscilloscope allows you to see:
Pulse presence
Pulse width
Frequency
Timing
This can be much more useful during troubleshooting.
Example: PWM Sensor Output
Some electronic systems use PWM to represent a changing value.
In this situation, the important information may be contained in:
Duty cycle
rather than simply the average voltage.
An oscilloscope is particularly useful because you can see the pulse pattern directly.
Step 1: Identify the Sensor Supply Voltage
Before checking the output, determine:
What voltage should power the sensor?
Depending on the design, this might be:
3.3 V
5 V
12 V
or another specified voltage.
Do not assume every sensor uses the same supply.
Step 2: Confirm the Sensor Has Power
Use an appropriate meter to verify the supply.
If the sensor does not receive the correct power, there is little value diagnosing the output first.
A missing sensor output may simply be caused by:
Missing supply
Broken wire
Connector problem
Poor ground/reference
Regulator problem
Step 3: Identify the Correct Output Wire or Test Point
Do not probe random pins.
Determine:
Power
Reference
Output
and any additional connections.
If a datasheet or wiring diagram is available, use it.
Connecting an oscilloscope to the wrong pin can produce misleading results.
Step 4: Determine the Expected Output
Before looking at the screen, ask:
What should happen when the sensor is activated?
For example:
Voltage should increase
Voltage should decrease
Output should switch HIGH
Output should switch LOW
Pulses should appear
Frequency should increase
This gives you a reference for interpreting the waveform.
Step 5: Observe the Sensor at Rest
Measure the output when the sensor is in its normal or inactive condition.
Record what you see.
For example:
Stable LOW
Stable HIGH
Fixed DC voltage
Repeated pulses
Then activate the sensor and compare.
Step 6: Activate the Sensor
Depending on the sensor, change the measured condition.
For example:
Move a target
Rotate a shaft
Move a magnet
Change light level
Change position
Apply the normal operating condition
Observe whether the waveform changes.
Example: Hall Sensor
A suitable Hall-effect sensor may respond to a magnetic field.
Depending on the sensor type, you may observe:
Digital switching
or
Changing analogue voltage
Move the magnet or target and observe the response.
If the sensor has correct power but the expected output never changes, further investigation is required.
Example: Proximity Sensor
Suppose a low-voltage proximity sensor is connected to a control PCB.
The machine reports that the sensor is not detecting a target.
Check:
Sensor power
then
Sensor output
Move the target into and out of the sensing area.
If the sensor output changes correctly but the controller does not respond, investigate the signal path after the sensor.
Sensor Works but Controller Does Not See It
This is an important troubleshooting situation.
Suppose:
Sensor output = Correct
but
Controller input = No signal
Now trace the signal.
The path may include:
Connector
Resistor
Filter
Optocoupler
Buffer
Signal-conditioning circuit
PCB track
Measure before and after each relevant stage.
The fault may not be the sensor.
Controller Input Has Signal but Reading Is Wrong
Suppose the expected signal reaches the controller.
The problem may then involve:
Signal interpretation
Calibration
Software
Reference voltage
Incorrect configuration
Another sensor input
At this stage, simply replacing the sensor may not solve the problem.
Sensor Output Is Stuck HIGH
If a sensor output remains HIGH regardless of the measured condition, investigate:
Actual sensor behaviour
Wiring
Pull-up circuit
Output configuration
Signal path
Sensor fault
Some sensor outputs require external components, so understand the circuit before diagnosing the sensor.
Sensor Output Is Stuck LOW
Similarly, a permanently LOW signal may result from:
Sensor condition
Short circuit
Missing pull-up
Faulty wiring
Incorrect power
Faulty sensor
Downstream circuit pulling the signal down
Measure at multiple points if necessary.
Sensor Output Changes at the Sensor but Not After the Connector
Suppose:
Sensor output pin = Good
but
PCB connector output = Missing
Now you have narrowed the problem significantly.
Check:
Cable
Connector
Terminal
Broken conductor
Poor contact
This is why signal tracing is so effective.
Intermittent Sensor Signal
Some sensor problems occur only occasionally.
The signal may disappear because of:
Loose connector
Vibration
Damaged cable
Temperature
Mechanical movement
Power instability
Sensor internal fault
An oscilloscope may help reveal brief interruptions that are difficult to catch with a multimeter.
Use Single Trigger for Occasional Pulses
If the sensor produces a one-time or occasional event, Single Trigger may be useful.
For example:
Object passes sensor
→ pulse occurs once.
Instead of trying to watch continuously, configure the trigger to capture a suitable event.
This can make intermittent pulse testing easier.
Check the Trigger Level
If the trigger level is outside the signal amplitude, the waveform may not stabilise or capture as expected.
For example, if a digital sensor switches between approximately:
0 V and 5 V
the trigger level should be chosen appropriately within the signal range.
Trigger settings do not increase the oscilloscope's input capability.
Check the Time Base
A sensor signal can appear completely different depending on the time scale.
If the pulses occur slowly, use a slower time base.
If the pulses are faster, use an appropriate faster time base.
The objective is to display enough of the waveform to understand the pattern.
Check the Voltage Scale
If a 3.3 V sensor signal appears tiny on the screen, adjust the vertical scale.
Similarly, if the waveform goes outside the display, use a more suitable range.
Correct scaling makes interpretation much easier.
Analogue Sensor: Look for Smooth Changes
For an analogue sensor, observe whether the output changes reasonably as the measured condition changes.
Possible abnormal behaviour includes:
Sudden jumps
Dropouts
Unexpected noise
No response
Output stuck at one level
But remember that the expected behaviour depends on the specific sensor.
Pulse Sensor: Look at Frequency
Some sensors represent speed or movement using pulse frequency.
For example, increasing rotational speed may produce pulses more frequently.
The oscilloscope can help you observe whether:
Pulses exist
and
Frequency changes with speed
This can be useful for suitable tachometer or rotational sensing applications.
PWM Sensor: Look at Duty Cycle
If the sensor uses PWM, the frequency may remain relatively constant while the duty cycle changes.
For example:
Low measurement value → lower duty cycle
Higher measurement value → higher duty cycle
The exact relationship depends on the sensor specification.
Do not assume every PWM sensor follows the same behaviour.
Can DSO-152 Plus Test Temperature Sensors?
It depends on the sensor type.
Some temperature sensors produce:
Analogue voltage
Some are:
Resistive sensors
Others communicate digitally using a protocol.
An oscilloscope is useful only when the sensor output produces an appropriate electrical waveform to observe.
For a simple resistive temperature sensor, a multimeter may be more appropriate.
Can It Test Speed Sensors?
For suitable low-voltage speed sensors that generate pulses, an oscilloscope can be very useful.
You may check:
Pulse presence
Frequency
Signal stability
Changes with speed
However, automotive and industrial sensors can use different electrical systems, so confirm the signal type and voltage first.
Can It Test Automotive Sensors?
Some low-voltage automotive sensor signals may be suitable for oscilloscope observation.
But automotive electronics can also contain:
Inductive spikes
Injector signals
Ignition systems
Alternator disturbances
Higher-voltage transients
Do not assume every automotive signal is safe for an entry-level oscilloscope.
Use appropriate automotive test equipment where necessary.
Can It Test Industrial Sensors?
Industrial sensors may use standards such as:
0–10 V
4–20 mA
Pulse outputs
Digital communication
The DSO-152 Plus is not automatically suitable for every industrial sensor.
For example, 4–20 mA is a current-loop signal and is normally approached differently from directly measuring a simple voltage-output sensor.
Understand the loop and measurement method before connecting the oscilloscope.
Sensor Communication vs Sensor Output
Modern sensors may communicate using:
UART
I2C
SPI
or other digital protocols.
An oscilloscope may confirm electrical activity.
But if you need to know:
What data is being transmitted?
What address is used?
What packet was sent?
a logic analyser or protocol-capable instrument may be more appropriate.
Compare with a Working Sensor
If you have two identical sensors, compare them under the same conditions.
For example:
Working sensor = Clean changing pulse
Suspected sensor = No output
This comparison can be more useful than guessing what the waveform should look like.
Compare with a Working PCB
You can also compare:
Good machine
and
Faulty machine
Measure the same sensor signal at the same test point.
If the waveforms are different, continue tracing until you identify where the difference begins.
Don't Replace the Sensor Too Quickly
A machine reports:
Sensor Error
That does not automatically mean:
Sensor is faulty.
The actual problem may be:
Power supply
Cable
Connector
Signal-conditioning circuit
Controller input
Configuration
Mechanical target
Software
Test systematically before replacing parts.
DSO-152 Plus vs Multimeter for Sensor Testing
Use the multimeter for suitable checks such as:
Supply voltage
Resistance
Continuity
Slow DC output
Use the oscilloscope when you need to see:
Pulses
PWM
Frequency
Intermittent signals
Fast voltage changes
Waveform shape
Often, using both instruments provides the fastest diagnosis.
When Is DSO-152 Plus Suitable?
For suitable low-voltage sensor circuits, the DSO-152 Plus can help answer:
Does the sensor have an output?
Does the output change?
Is there a pulse?
Is PWM present?
Does frequency change?
Does the signal reach the controller?
These are excellent basic troubleshooting questions.
When Do You Need Better Equipment?
Consider a more capable oscilloscope or specialised instrument for:
High-frequency sensor signals
Very small analogue signals
Multiple signals simultaneously
Detailed digital protocol analysis
Automotive ignition-related measurements
Industrial high-voltage systems
Precision sensor development
Choose the test instrument according to the actual signal.
Safety Before Measuring a Sensor
Do not assume a circuit is safe simply because it contains a sensor.
The sensor may be installed in equipment containing:
Mains voltage
High-voltage power supplies
Industrial drives
Inverters
High-energy motor circuits
Identify the test point, expected voltage and circuit reference before connecting the oscilloscope.
Quick Sensor Troubleshooting Checklist
If a sensor appears not to work, check:
1. What type of sensor is it?
2. What supply voltage should it receive?
3. Is the supply present?
4. What output type should it produce?
5. What should happen when the sensor is activated?
6. Does the output change at the sensor?
7. Does the signal reach the PCB?
8. Does the signal reach the controller?
9. Is the signal intermittent?
10. Do you need waveform viewing or protocol decoding?
This helps separate a real sensor fault from a wiring or controller problem.
FNIRSI DSO-152 Plus Sensor Signal Testing Malaysia
The FNIRSI DSO-152 Plus can be a useful entry-level oscilloscope for troubleshooting suitable low-voltage sensor outputs.
Instead of immediately asking:
“Is the sensor bad?”
use a systematic approach:
Power → Sensor Output → Wiring → Signal Conditioning → Controller Input
This can help identify whether the problem is actually in the sensor or somewhere else in the signal path.
MTM Precision supplies FNIRSI oscilloscopes and electronic test instruments in Malaysia.
If you need to check a sensor signal, send us:
A photo of the sensor
Sensor model
Photo of the PCB or controller
Supply voltage
Expected output type if known
Photo or video of the waveform
through WhatsApp.
We can help determine whether the FNIRSI DSO-152 Plus is suitable or whether another oscilloscope, multimeter, signal analyser or specialised test instrument is more appropriate.
MTM Precision Sdn Bhd
Showroom & Service Centre:
No. 29-1 & 2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Supplying FNIRSI and electronic test instruments throughout Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kelantan, Terengganu, Kedah, Perlis, Sabah and Sarawak.
06 Oct 2026