Measuring battery internal resistance requires greater attention to measurement technique than ordinary battery voltage testing.
Many rechargeable batteries have internal resistance values measured in milliohms (mΩ). At these low resistance levels, even small amounts of test lead resistance can significantly affect measurement accuracy.
The FNIRSI HRM-10 Battery Internal Resistance Tester uses a four-wire Kelvin measurement method to help reduce the influence of test lead resistance.
This measurement technique is particularly useful for 18650 lithium battery testing, battery cell comparison, battery repair and low-resistance inspection.
In this article, we explain how four-wire Kelvin measurement works, why it is useful and how technicians in Malaysia can obtain more consistent battery resistance readings.
What Is Four-Wire Kelvin Measurement?
Four-wire Kelvin measurement, also known as four-terminal sensing, is a technique used to measure low electrical resistance.
Instead of using the same two conductors for both the test current and voltage measurement, the Kelvin method separates these functions.
A typical four-wire measurement arrangement uses:
-
Two current connections to apply a controlled test signal.
-
Two voltage sensing connections to measure the resulting voltage difference.
By separating the current and voltage measurement paths, the instrument can reduce the influence of voltage drops along the current-carrying test leads.
This is especially useful when measuring resistance values in milliohms.
Why Is Four-Wire Measurement Important for Battery Testing?
Battery internal resistance is often extremely low.
For example, a lithium-ion battery cell may have an internal resistance of only a few tens of milliohms.
At these resistance levels, ordinary test leads can introduce substantial measurement errors.
Consider a simplified example.
| Parameter | Resistance |
|---|---|
| Actual Resistance Under Test | 20mΩ |
| Combined Test Lead Resistance | 40mΩ |
| Two-Wire Measurement Result | 60mΩ |
| Ideal Four-Wire Result | 20mΩ |
This is a simplified illustration of resistance measurement. Actual battery AC impedance measurements involve additional considerations.
In a conventional two-wire measurement, the resistance of the leads may be included in the measured value.
With a correctly implemented four-wire measurement, the influence of the current-carrying lead resistance is greatly reduced.
Four-wire Kelvin measurement is therefore particularly valuable when measuring very low resistance values.
Two-Wire vs Four-Wire Resistance Measurement
The following table summarizes the differences.
| Feature | Two-Wire Measurement | Four-Wire Kelvin Measurement |
|---|---|---|
| Number of Connections | Two | Four |
| Current and Voltage Paths | Shared | Separated |
| Lead Resistance Influence | Greater | Reduced |
| Milliohm Measurement | More Challenging | Better Suited |
| Connection Complexity | Simpler | More Connections |
| Common Applications | General Resistance Testing | Low-Resistance and Battery Testing |
Two-wire measurement remains useful for many electrical applications.
However, four-wire measurement is generally preferred when lead resistance is significant compared with the resistance being measured.
How Does the FNIRSI HRM-10 Use Kelvin Measurement?
The FNIRSI HRM-10 is designed to measure battery internal resistance using an approximately 1kHz AC test signal.
Its four-wire measurement arrangement helps separate the test current path from the voltage sensing path.
The instrument uses the relationship between the applied AC signal and measured response to determine the battery's internal resistance reading.
This method is different from measuring a passive resistor using the ordinary ohms function of a digital multimeter.
Battery AC internal resistance is frequency-dependent and should not automatically be treated as equivalent to DC resistance under load.
The HRM-10 also measures DC battery voltage, allowing technicians to record both parameters during battery inspection.
Why Does FNIRSI HRM-10 Use an AC Measurement Method?
Batteries are active electrochemical devices.
Applying the ordinary resistance measurement function of a digital multimeter directly across a live battery is generally inappropriate and may damage the meter.
Dedicated battery resistance testers use measurement methods designed for energized battery cells within specified limits.
The FNIRSI HRM-10 uses an approximately 1kHz AC measurement method for internal resistance testing.
AC resistance measurement can provide a useful indicator for comparing batteries of the same type.
However, battery impedance varies with frequency, chemistry, temperature and state of charge.
Measurements obtained using different instruments or test frequencies may not be directly interchangeable.
Understanding Milliohm Measurement
A milliohm (mΩ) is one-thousandth of an ohm.
The relationship is:
1Ω = 1000mΩ
Examples include:
| Resistance in Ohms | Resistance in Milliohms |
|---|---|
| 0.001Ω | 1mΩ |
| 0.005Ω | 5mΩ |
| 0.010Ω | 10mΩ |
| 0.025Ω | 25mΩ |
| 0.050Ω | 50mΩ |
| 0.100Ω | 100mΩ |
Battery internal resistance is often expressed in milliohms because many rechargeable cells have relatively low resistance.
When comparing batteries, even small changes may be meaningful depending on the battery model and measurement conditions.
FNIRSI HRM-10 Main Technical Features
| Parameter | Description |
|---|---|
| Model | FNIRSI HRM-10 |
| Instrument Type | Battery Internal Resistance Tester |
| Resistance Measurement | Up to 200Ω |
| DC Voltage Measurement | Up to ±100V DC |
| Test Signal | Approximately 1kHz AC |
| Measurement Method | Four-Wire Kelvin |
| Main Applications | Battery Inspection and Resistance Comparison |
| Additional Functions | Sorting and Measurement Recording |
Note: Measurement resolution, accuracy and permitted operating conditions depend on the selected range. Refer to the latest official FNIRSI specifications for detailed information.
How to Improve Measurement Consistency
Even with four-wire Kelvin measurement, proper testing technique remains important.
1. Maintain Clean Battery Terminals
Dirty or corroded battery terminals can create unstable electrical contact.
Recommendation: Ensure terminals are suitable for measurement and follow safe cleaning procedures where appropriate.
2. Apply Stable Probe Contact
Inconsistent probe pressure or positioning can affect readings.
Recommendation: Maintain stable probe contact and repeat measurements when necessary.
3. Test Similar Batteries at Similar Temperatures
Battery internal resistance changes with temperature.
Recommendation: Record temperature and compare batteries under consistent conditions.
4. Compare the Same Battery Models
Different battery designs can have different internal resistance characteristics.
Recommendation: Compare cells of the same chemistry, manufacturer and model whenever possible.
5. Follow the Instrument Operating Instructions
Incorrect lead connections or unsuitable test conditions may affect results.
Recommendation: Follow the FNIRSI manual for lead connections, measurement ranges and applicable zero-adjustment procedures.
Example - Comparing Four 18650 Lithium Battery Cells
Consider four lithium-ion cells of the same model.
| Battery Cell | Voltage | Internal Resistance |
|---|---|---|
| Cell A | 3.81V | 23mΩ |
| Cell B | 3.82V | 24mΩ |
| Cell C | 3.81V | 25mΩ |
| Cell D | 3.82V | 76mΩ |
Illustrative values only, not universal acceptance limits.
Cells A, B and C have similar resistance readings.
Cell D shows a substantially higher resistance measurement.
A technician should repeat the measurement, check the contact conditions and investigate the difference.
The measurement may help identify a cell requiring additional capacity or performance testing.
A high resistance reading alone does not establish that a battery is defective.
Applications of Four-Wire Kelvin Battery Testing
Lithium Battery Cell Inspection
Four-wire measurement is useful for comparing low internal resistance values in rechargeable lithium-ion cells.
Battery Pack Assembly
Technicians can measure and compare individual cells before further sorting and qualification.
Battery Repair Workshops
Resistance measurements can support investigation of batteries with unusual electrical performance.
Electronics Laboratories
Four-wire measurement provides a practical way to study low-resistance testing principles.
Lead Acid Battery Inspection
The HRM-10 may be used for resistance measurements on compatible individual lead acid batteries under safe testing conditions.
Can Four-Wire Kelvin Measurement Eliminate All Errors?
No.
Although four-wire Kelvin measurement reduces lead resistance influence, other factors can still affect measurement results.
These include:
-
Probe contact quality
-
Battery temperature
-
Battery state of charge
-
Electrical interference
-
Instrument accuracy
-
Battery chemistry
-
Measurement frequency
-
Incorrect measurement setup
For reliable battery comparisons, technicians should maintain consistent measurement conditions and follow the manufacturer's instructions.
FNIRSI HRM-10 vs Standard Multimeter Resistance Measurement
A conventional digital multimeter typically uses a two-wire resistance measurement method.
This is suitable for many general electrical measurements.
However, battery internal resistance testing requires a specialized approach.
| Application | FNIRSI HRM-10 | Standard Multimeter |
|---|---|---|
| Battery DC Voltage | Yes | Yes |
| Battery AC Internal Resistance | Yes | Generally No |
| Four-Wire Battery Measurement | Yes | Usually No |
| Milliohm Battery Comparison | Suitable | Generally Unsuitable |
| General Circuit Resistance | Not Its Primary Purpose | Suitable |
| General Electrical Troubleshooting | Limited | Suitable |
The FNIRSI HRM-10 complements a digital multimeter rather than replacing it.
Who Should Use a Four-Wire Battery Resistance Tester in Malaysia?
The FNIRSI HRM-10 may be useful for:
Electronics Repair Technicians
For testing rechargeable battery cells and investigating performance differences.
Battery Pack Assemblers
For measuring internal resistance during cell inspection.
Battery Maintenance Workshops
For comparing compatible individual batteries.
Engineering Laboratories
For low-resistance battery measurement and educational applications.
Industrial Maintenance Teams
For supplementary battery inspection under suitable conditions.
Frequently Asked Questions
Q1. What is four-wire Kelvin measurement?
It is a low-resistance measurement method that separates current-carrying connections from voltage sensing connections to reduce the influence of test lead resistance.
Q2. Why is four-wire measurement better for milliohm testing?
Because test lead resistance can be significant compared with the resistance being measured. Four-wire measurement reduces this source of error.
Q3. Does FNIRSI HRM-10 use four-wire Kelvin measurement?
Yes. The FNIRSI HRM-10 uses a four-wire measurement arrangement for battery internal resistance testing.
Q4. Can a normal digital multimeter measure battery internal resistance?
Most standard multimeters are not designed to measure the AC internal resistance of an energized battery cell.
Q5. Does four-wire Kelvin measurement guarantee perfect accuracy?
No. Measurement accuracy still depends on instrument specifications, probe contact, battery condition and testing environment.
Q6. Is FNIRSI HRM-10 suitable for 18650 lithium batteries?
Yes. It can measure internal resistance and DC voltage on compatible 18650 lithium-ion cells.
Conclusion
Four-wire Kelvin measurement is an important technique for low-resistance testing because it reduces the influence of test lead resistance.
The FNIRSI HRM-10 Battery Internal Resistance Tester combines four-wire measurement with an approximately 1kHz AC resistance testing method and DC voltage measurement.
This makes it useful for lithium battery inspection, battery cell comparison, electronics repair and selected battery maintenance applications.
For technicians, engineers and battery service workshops in Malaysia, understanding the Kelvin measurement method can help improve testing consistency and interpretation of battery resistance readings.
Where to Buy FNIRSI HRM-10 in Malaysia?
MTM Precision Sdn Bhd supplies electrical testing instruments, industrial measuring equipment and battery inspection tools in Malaysia.
Customers searching for FNIRSI HRM-10 Four Wire Kelvin Battery Internal Resistance Tester Malaysia can contact MTM Precision for product information, quotations and availability.
We support customers across Kuala Lumpur, Selangor, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Kelantan, Terengganu, Perlis, Sabah and Sarawak.
Contact MTM Precision Sdn Bhd
MTM Precision Sdn Bhd
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Contact MTM Precision today for FNIRSI HRM-10 product information, quotations and availability in Malaysia.
10 Oct 2026