Introduction

A rechargeable battery may appear fully charged but still deliver poor performance when connected to electrical equipment.

One possible reason is high battery internal resistance.

Internal resistance affects how a battery responds when electrical current flows. An increase in resistance can contribute to greater voltage drop, additional heating and reduced power delivery.

The FNIRSI HRM-10 Battery Internal Resistance Tester allows technicians to measure battery internal resistance and DC voltage using a dedicated handheld instrument.

This guide explains the common causes of high internal resistance, how to investigate unusual readings and how battery technicians in Malaysia can use the FNIRSI HRM-10 during troubleshooting.

What Is High Battery Internal Resistance?

Battery internal resistance is the opposition to electrical current within a battery.

It is commonly expressed in milliohms (mΩ) for rechargeable battery cells.

A battery with higher internal resistance may experience a larger voltage drop when supplying current.

However, there is no single resistance value that defines a defective battery across all battery types.

The correct interpretation depends on:

  • Battery chemistry

  • Manufacturer and model

  • Rated capacity

  • Battery temperature

  • State of charge

  • Battery age

  • Measurement method

A resistance reading should be evaluated against a suitable reference rather than a universal pass or fail threshold.

Common Symptoms of High Battery Internal Resistance

A battery with increased internal resistance may exhibit several symptoms.

1. Battery Voltage Drops Under Load

A battery may show normal voltage without a load but experience a significant voltage drop when equipment starts operating.

2. Equipment Shuts Down Unexpectedly

Battery-powered equipment may shut down when current demand increases.

However, unexpected shutdowns can also result from protection circuits, wiring faults or other equipment problems.

3. Battery Heats Up During Operation

Higher resistance can contribute to increased internal heating during current flow.

Abnormal battery heating requires careful investigation.

4. Reduced High-Current Performance

Equipment requiring substantial starting or operating current may perform poorly.

5. Uneven Battery Pack Performance

Cells with different electrical characteristics may behave differently within a battery pack.

These symptoms do not prove that internal resistance is the cause. Proper testing is necessary.

What Causes High Battery Internal Resistance?

Cause 1 - Battery Ageing

Rechargeable batteries undergo chemical and physical changes during use and storage.

These changes may increase internal resistance over time.

Troubleshooting: Compare current measurements with previous records or suitable manufacturer reference values.

Cause 2 - Low Battery Temperature

Battery internal resistance generally increases at lower temperatures.

A cold battery may therefore show a higher resistance reading than the same battery at a warmer temperature.

Troubleshooting: Compare measurements under similar temperature conditions.

Cause 3 - Battery Deterioration

Electrode degradation, electrolyte changes and other electrochemical processes can affect battery resistance.

Troubleshooting: Combine resistance measurement with capacity testing and other appropriate diagnostic methods.

Cause 4 - Incorrect State of Charge

Internal resistance can vary with battery state of charge.

Comparing a fully charged cell with a significantly discharged cell may produce misleading conclusions.

Troubleshooting: Compare batteries at similar states of charge whenever practical.

Cause 5 - Poor Measurement Contact

Dirty terminals, damaged probes or unstable connections can produce inconsistent resistance readings.

Troubleshooting: Check probe contact and repeat the measurement.

Cause 6 - Different Battery Specifications

Two batteries with different capacity ratings or internal construction may naturally have different resistance values.

Troubleshooting: Compare batteries of the same manufacturer, model and chemistry.

How FNIRSI HRM-10 Helps Troubleshoot Battery Resistance

The FNIRSI HRM-10 measures battery internal resistance and DC voltage.

Its main features include:

Feature Description
Internal Resistance Measurement Measures battery AC internal resistance
DC Voltage Measurement Checks battery terminal voltage
Four-Wire Kelvin Connection Reduces lead resistance influence
AC Test Frequency Approximately 1kHz
Resistance Measurement Range Up to 200Ω
DC Voltage Range Up to ±100V DC
Sorting Function Supports resistance comparison
Measurement Recording Supports inspection records

Important: Measurement accuracy, resolution and permitted operating conditions depend on the instrument's specifications and selected range.

Step-by-Step Battery Resistance Troubleshooting

Step 1 - Identify the Battery

Confirm the battery chemistry, manufacturer, model and nominal voltage.

For example, a lithium-ion 18650 cell should not be evaluated using the same resistance criteria as a large lead acid battery.

Step 2 - Inspect the Battery

Check for:

  • Swelling or deformation

  • Leakage

  • Corrosion

  • Damaged insulation

  • Burn marks

  • Signs of overheating

Do not perform routine testing on visibly unsafe batteries.

Step 3 - Check the Testing Conditions

Record the battery temperature and approximate state of charge.

These factors can affect resistance measurements.

Step 4 - Connect the FNIRSI HRM-10

Connect the supplied Kelvin probes according to the manufacturer's instructions.

Ensure the battery is compatible with the tester and is in a safe testing condition.

Step 5 - Measure Voltage and Internal Resistance

Record both measurements.

Use consistent probe placement and contact pressure.

Step 6 - Repeat the Measurement

If the resistance reading appears unusual, repeat the test.

Check whether the reading remains stable.

Step 7 - Compare with Reference Values

Compare the results with:

  • Manufacturer specifications

  • Historical baseline measurements

  • Similar cells of the same model

  • Established maintenance criteria

Step 8 - Perform Additional Testing

If the battery continues to show unusual readings, further testing may be necessary.

This may include controlled capacity testing, load testing or other manufacturer-recommended procedures.

Example - High Resistance in 18650 Lithium Batteries

Consider four lithium-ion cells of the same model.

Cell Voltage Internal Resistance Observation
A 3.82V 24mΩ Similar to Reference Cells
B 3.81V 25mΩ Similar to Reference Cells
C 3.83V 26mΩ Similar to Reference Cells
D 3.82V 88mΩ Requires Further Investigation

Illustrative example only. These values are not universal acceptance limits.

All four cells show similar voltage readings.

However, Cell D has substantially higher internal resistance.

The technician should repeat the measurement and verify the testing conditions.

If the difference remains, Cell D may require further capacity or performance evaluation.

A high internal resistance reading alone does not establish that a cell is defective.

High Internal Resistance vs Low Battery Capacity

High internal resistance and low battery capacity are related but different battery characteristics.

Parameter High Internal Resistance Low Battery Capacity
Main Concern Opposition to Current Flow Reduced Available Charge
Possible Symptom Voltage Drop Under Load Short Operating Runtime
Measurement Unit mΩ or Ω mAh or Ah
Suitable Instrument Battery Resistance Tester Battery Capacity Tester
FNIRSI HRM-10 Measures This Parameter Does Not Directly Measure

A battery may have increased internal resistance, reduced capacity or both.

Therefore, battery internal resistance testing should complement rather than replace capacity testing.

Why Four-Wire Kelvin Measurement Matters

When testing battery internal resistance, the resistance being measured may be extremely small.

Ordinary test lead resistance can affect low-resistance measurements.

The FNIRSI HRM-10 uses four-wire Kelvin measurement to reduce the influence of lead resistance.

This is useful when comparing lithium-ion cells or other compatible batteries with low internal resistance.

However, Kelvin measurement does not eliminate errors caused by unstable contact, temperature changes or unsuitable measurement conditions.

Troubleshooting Battery Resistance in Lead Acid Batteries

Lead acid batteries are commonly used in:

  • Emergency lighting

  • Security alarm systems

  • UPS backup equipment

  • Industrial control systems

  • Portable electrical equipment

An increase in resistance may be associated with ageing, sulfation or other deterioration.

However, the correct resistance reference depends on battery design and capacity.

For example, a small 12V sealed lead acid battery should not be compared directly with a large automotive starting battery.

The FNIRSI HRM-10 may support resistance measurement on compatible individual batteries under safe testing conditions.

For critical backup power installations, use appropriately rated professional equipment and manufacturer-approved maintenance procedures.

Common Measurement Problems and Solutions

Problem Possible Cause Recommended Action
Unstable Resistance Reading Poor Probe Contact Reposition Probes
Unexpectedly High Reading Contact or Battery Condition Repeat and Compare
Different Results Between Tests Temperature or Charge Difference Standardize Conditions
Similar Voltage but Different Resistance Cell Characteristics or Deterioration Perform Additional Testing
No Reliable Reading Incorrect Connection or Unsupported Condition Check Manual and Setup

Never attempt to test an unsafe or damaged battery merely to obtain a resistance reading.

When Should a Battery Be Replaced?

Battery replacement decisions should consider more than a single internal resistance measurement.

Important factors may include:

  • Manufacturer replacement criteria

  • Measured capacity

  • Performance under load

  • Physical condition

  • Battery age

  • Operating requirements

  • Maintenance history

  • Safety considerations

For critical applications, follow the equipment manufacturer's approved battery replacement procedures.

Applications in Malaysia

The FNIRSI HRM-10 Battery Internal Resistance Tester can support battery troubleshooting in several industries.

Electronics Repair Workshops

For investigating rechargeable battery performance problems.

Lithium Battery Pack Assembly

For identifying unusual resistance differences between compatible cells.

Industrial Equipment Maintenance

For inspecting batteries used in portable industrial equipment.

Battery Service Workshops

For supplementary inspection of compatible lead acid and lithium batteries.

Engineering Laboratories

For battery testing experiments and technical measurements.

Frequently Asked Questions

Q1. What causes high battery internal resistance?

Possible causes include battery ageing, electrochemical deterioration, temperature changes and battery condition. Measurement contact problems can also produce unusually high readings.

Q2. Can a battery have normal voltage but high internal resistance?

Yes. Open-circuit voltage and internal resistance measure different battery characteristics.

Q3. Can FNIRSI HRM-10 identify high internal resistance?

Yes. The FNIRSI HRM-10 measures battery internal resistance and allows technicians to compare readings with suitable reference values.

Q4. Does high internal resistance always mean a battery is bad?

No. Resistance must be interpreted according to battery type, temperature, state of charge and manufacturer specifications.

Q5. Can FNIRSI HRM-10 measure battery capacity?

No. It measures internal resistance and DC voltage, not actual discharge capacity in mAh or Ah.

Q6. Can battery internal resistance be reduced?

Some resistance changes are related to reversible operating conditions such as temperature or state of charge. Other changes result from permanent deterioration. Do not attempt unsafe battery restoration procedures.

Conclusion

High battery internal resistance can contribute to voltage drop, heating and reduced current delivery.

However, an unusual resistance reading should always be interpreted in the context of battery type, temperature, state of charge and measurement conditions.

The FNIRSI HRM-10 Battery Internal Resistance Tester provides a practical method for measuring battery internal resistance and DC voltage.

Its four-wire Kelvin measurement arrangement supports low-resistance battery inspection and comparison.

For electronics repair workshops, battery technicians and industrial maintenance teams in Malaysia, the HRM-10 can help identify batteries that require further investigation.

Internal resistance testing is a diagnostic tool, not a complete battery health or capacity test.

Where to Buy FNIRSI HRM-10 in Malaysia?

MTM Precision Sdn Bhd supplies electrical testing instruments, industrial measuring equipment and battery inspection tools in Malaysia.

Customers searching for FNIRSI HRM-10 Battery Internal Resistance Tester Malaysia can contact MTM Precision for product information, quotations and availability.

We support customers across Kuala Lumpur, Selangor, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Kelantan, Terengganu, Perlis, Sabah and Sarawak.

Contact MTM Precision Sdn Bhd

MTM Precision Sdn Bhd

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.

Tel: 03-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com

Website: www.mtmpre.com.my

Contact MTM Precision today for FNIRSI HRM-10 product information, quotations and availability in Malaysia.

10 Oct 2026