RSK-2002 Precision Level 0.02mm/m for Machine Tool Alignment Malaysia
RSK-2002 Precision Level 0.02mm/m for Machine Tool Alignment Malaysia
Introduction to RSK-2002 Precision Flat Level
The RSK-2002 Precision Flat Level is a Japan-made precision spirit level designed for machine tool leveling, CNC machine installation, precision equipment setup, and industrial machine alignment inspection.
Industrial machine tools require suitable installation conditions to maintain their intended geometry and operating performance.
In Malaysia, CNC machining workshops, precision engineering companies, machinery installation contractors, and factory maintenance departments use precision measuring instruments to support machine installation and maintenance procedures.
The RSK-2002 Precision Level features a 200 mm nominal measuring length and 0.02 mm/m sensitivity, making it an option for applications requiring fine inclination readings over a relatively long measuring base.
MTM Precision Sdn Bhd supplies the RSK-2002, together with the RSK-1502 and RSK-1505, for industrial customers throughout Malaysia.
What Is the RSK-2002 Precision Level?
The RSK-2002 Precision Flat Level is a mechanical spirit level designed to indicate small deviations from a horizontal reference.
Unlike ordinary construction spirit levels, precision machine levels offer finer sensitivity for industrial measuring applications.
The RSK-2002 can be considered for:
CNC Machine Leveling
Machine Tool Installation
Lathe Machine Bed Leveling
Milling Machine Setup
Precision Equipment Alignment
Machine Relocation Inspection
Industrial Maintenance
Machine Installation Verification
Its 200 mm measuring length makes it suitable for appropriate reference surfaces that can accommodate a longer instrument body.
RSK-2002 Precision Level Technical Specifications
SpecificationRSK-2002BrandRSKModelRSK-2002Product TypePrecision Flat LevelCountry of OriginJapanNominal Measuring Length200 mmNominal Sensitivity0.02 mm/mMeasurement PrincipleSpirit Bubble LevelPrimary ApplicationPrecision Machine Leveling
Important: Sensitivity represents the inclination corresponding to one scale division. It should not be interpreted as a guaranteed overall measurement accuracy.
Instrument tolerance, condition, measurement technique, and environmental stability must also be considered.
Understanding RSK-2002 Sensitivity of 0.02mm/m
The RSK-2002 Precision Level has a nominal sensitivity of 0.02 mm/m.
This means that one scale division corresponds to an inclination equivalent to a height difference of 0.02 mm over a horizontal distance of one metre.
The equivalent inclination for different scale divisions is shown below.
Scale DivisionEquivalent Inclination1 Division0.02 mm/m2 Divisions0.04 mm/m3 Divisions0.06 mm/m4 Divisions0.08 mm/m5 Divisions0.10 mm/m
For example, if the bubble indicates an inclination of three divisions, the corresponding nominal inclination is 0.06 mm/m.
This does not mean the machine itself has moved vertically by 0.06 mm. The reading represents an inclination, not an absolute height measurement.
Why Choose a 200mm Precision Level?
One important characteristic of the RSK-2002 is its 200 mm nominal measuring length.
Compared with a shorter precision level, a longer measuring base can be useful on sufficiently large, flat reference surfaces.
1. Suitable for Longer Machine Reference Surfaces
The 200 mm body can be positioned on appropriate machine surfaces that provide sufficient contact area.
2. Useful for Machine Tool Installation
Machine installation engineers can use the instrument to check designated leveling reference points.
3. Fine Inclination Sensitivity
The 0.02 mm/m sensitivity supports fine inclination readings during precision machine leveling.
4. Industrial Maintenance Applications
Maintenance technicians can use the instrument to compare leveling conditions at specified positions.
5. Mechanical Measurement Without Electronic Power
As a mechanical spirit level, the instrument does not require batteries for normal inclination measurement.
Note: A longer level is not automatically more accurate. Surface flatness, instrument condition, and the required measuring procedure determine whether the 200 mm model is appropriate.
RSK-2002 for CNC Machine Installation
CNC machine leveling is an important procedure during machine installation and commissioning.
A CNC machine must be supported according to the manufacturer's installation instructions.
Improper support adjustment may introduce unwanted mechanical stress or affect machine geometry.
The RSK-2002 Precision Level can assist technicians in checking suitable reference surfaces during installation.
Typical CNC Installation Applications
CNC Machining Centres
Checking designated leveling references during installation.
CNC Lathe Machines
Assessing machine bed leveling conditions according to the manufacturer's procedure.
Precision Milling Machines
Checking suitable machine reference surfaces before final installation verification.
Machine Relocation
Comparing leveling conditions after machinery has been moved or reinstalled.
Industrial Maintenance
Checking machine support conditions during scheduled maintenance.
The correct measurement locations and acceptance limits must follow the machine manufacturer's instructions.
RSK-2002 for Lathe Machine Bed Leveling
Lathe machine leveling is one of the common applications for precision spirit levels.
A lathe machine bed may be affected by uneven support conditions.
During installation, technicians may need to check leveling at multiple positions to assess the machine's installation condition.
Basic Lathe Leveling Procedure
Step 1 - Prepare the Machine
Ensure the lathe is stationary and safe for inspection.
Step 2 - Clean the Reference Surface
Remove oil, dust, and metal particles from the designated measuring locations.
Step 3 - Position the RSK-2002
Place the precision level carefully on an approved reference surface.
Step 4 - Record the Bubble Reading
Allow the bubble to stabilize before recording the scale reading.
Step 5 - Check Additional Locations
Repeat measurements at the positions required by the machine manufacturer.
Step 6 - Adjust the Machine Supports
Adjust the leveling feet according to the specified installation sequence.
Step 7 - Verify the Results
Repeat the measurements and compare the results with the manufacturer's acceptance criteria.
Important: A centered bubble at one position does not necessarily indicate that a lathe bed is free from twist. Machine geometry verification may require additional measurements and instruments.
RSK-2002 for Milling Machine Leveling
Milling machine installation requires suitable mechanical support and correct machine setup.
The RSK-2002 Precision Flat Level can be used to check appropriate leveling references on milling machines.
Potential applications include:
Vertical Milling Machine Installation
Horizontal Milling Machine Setup
CNC Machining Centre Leveling
Machine Tool Relocation
Industrial Machine Maintenance
When selecting a precision level for a milling machine, the measuring surface must be suitable for the instrument's base length.
Users should also confirm the required sensitivity and measurement method before beginning work.
Machine Tool Alignment vs Machine Leveling
Although the terms are sometimes used together, machine leveling and machine alignment are not identical procedures.
Machine Leveling
Machine leveling involves checking and adjusting the inclination or support conditions of a machine according to its installation requirements.
A precision spirit level is commonly used for this purpose.
Machine Alignment
Machine alignment may involve checking relationships between mechanical components, axes, guideways, or moving parts.
Depending on the machine, alignment inspection may require additional instruments such as:
Dial Indicators
Precision Straightedges
Test Mandrels
Precision Squares
Laser Alignment Instruments
Other Machine Geometry Measuring Tools
The RSK-2002 Precision Level supports leveling measurements but does not replace a complete machine alignment inspection.
How to Use RSK-2002 Precision Level Correctly
Correct handling and measurement technique are essential when using a high-sensitivity precision level.
Step 1 - Inspect the Precision Level
Check the instrument for visible damage, contamination, or abnormal bubble movement.
Step 2 - Clean the Measuring Base
Remove dust, oil, and particles from the instrument's contact surface.
Step 3 - Prepare the Machine Surface
Ensure the selected reference surface is clean, stable, and appropriate for precision measurement.
Step 4 - Place the Level Carefully
Position the RSK-2002 without impact or excessive force.
Step 5 - Wait for Bubble Stabilization
Allow the bubble to settle before recording the reading.
Step 6 - Record the Measurement
Record the scale divisions and measurement position.
Step 7 - Repeat and Verify
Repeat measurements as required by the machine installation procedure.
For critical inspections, ensure the precision level has an appropriate inspection or calibration status.
Common Problems During Precision Machine Leveling
Problem 1 - Bubble Reading Changes Repeatedly
Possible causes include vibration, unstable machine supports, or temperature changes.
Recommended Action: Allow the machine and instrument to stabilize before repeating the measurement.
Problem 2 - Different Readings at Different Positions
Possible causes include changes in surface inclination, machine bed twist, or unsuitable measuring surfaces.
Recommended Action: Follow the machine manufacturer's specified measurement positions and inspection procedure.
Problem 3 - Bubble Does Not Settle
Possible causes include machine movement, nearby vibration, or instrument problems.
Recommended Action: Check measurement conditions and inspect the instrument before continuing.
Problem 4 - Machine Remains Uneven After Adjustment
Possible causes include incorrect adjustment sequence, unstable supports, or foundation conditions.
Recommended Action: Review the machine installation instructions and check the support system.
Problem 5 - Level Readings Are Inconsistent
Possible causes include dirt, poor surface contact, temperature differences, or instrument condition.
Recommended Action: Clean the contact surfaces and verify the precision level using the prescribed inspection method.
RSK-2002 vs RSK-1502 vs RSK-1505
MTM Precision Sdn Bhd supplies three RSK Precision Flat Level models.
ModelNominal LengthSensitivityRSK-2002200 mm0.02 mm/mRSK-1502150 mm0.02 mm/mRSK-1505150 mm0.05 mm/m
RSK-2002 - 200mm 0.02mm/m
Suitable for fine leveling applications where a longer measuring base can be accommodated.
RSK-1502 - 150mm 0.02mm/m
Offers the same nominal sensitivity in a shorter body for suitable compact measuring surfaces.
RSK-1505 - 150mm 0.05mm/m
An option for machine leveling procedures where 0.05 mm/m sensitivity is sufficient.
Which Model Should You Choose?
Select the model according to:
Required Sensitivity
Available Measuring Surface
Machine Manufacturer Requirements
Inspection Procedure
Instrument Condition and Calibration Requirements
Who Uses RSK-2002 Precision Levels in Malaysia?
The RSK-2002 Precision Flat Level is relevant to several industrial customer groups.
CNC Machine Workshops
For machine installation, leveling inspection, and maintenance.
Precision Engineering Companies
For suitable machine setup and leveling applications.
Machine Tool Dealers
For machine delivery, commissioning, and installation support.
Industrial Maintenance Contractors
For machinery relocation, reinstallation, and leveling inspection.
Manufacturing Factories
For machine installation and preventive maintenance procedures.
Mechanical Engineering Service Providers
For machine support adjustment and installation verification.
RSK-2002 Precision Level Supplier in Malaysia
MTM Precision Sdn Bhd supplies RSK-2002 Precision Flat Levels for industrial machine leveling and precision engineering applications.
We support enquiries from customers in:
Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Kelantan, Terengganu, Perlis, Sabah, and Sarawak.
Available RSK models include:
RSK-1502 Precision Flat Level
RSK-1505 Precision Flat Level
RSK-2002 Precision Flat Level
Customers can contact MTM Precision for product selection assistance and quotations.
Frequently Asked Questions
What is the sensitivity of RSK-2002?
The RSK-2002 Precision Flat Level has a nominal sensitivity of 0.02 mm/m.
What is the length of RSK-2002?
The RSK-2002 has a 200 mm nominal measuring length.
Can RSK-2002 be used for CNC machine leveling?
Yes. It can be used for suitable CNC machine leveling measurements, provided the instrument meets the machine manufacturer's requirements.
What is the difference between RSK-1502 and RSK-2002?
Both models have 0.02 mm/m sensitivity. The RSK-1502 is 150 mm, while the RSK-2002 is 200 mm.
Is a 200mm precision level more accurate than a 150mm precision level?
Not necessarily. A longer measuring base does not automatically provide greater accuracy. The instrument's specifications, measuring surface, condition, and procedure all affect the measurement.
Can RSK-2002 measure machine alignment?
The RSK-2002 measures inclination and can support machine leveling procedures. Complete machine alignment may require additional measuring instruments.
Where can I buy RSK-2002 in Malaysia?
Contact MTM Precision Sdn Bhd for RSK-2002 product information and quotations.
Contact MTM Precision Sdn Bhd
Looking for an RSK-2002 Precision Level 0.02mm/m in Malaysia?
MTM Precision Sdn Bhd supplies precision measuring instruments for CNC machine installation, machine tool leveling, industrial maintenance, and precision engineering applications.
Available RSK Models:
RSK-1502 Precision Flat Level
RSK-1505 Precision Flat Level
RSK-2002 Precision Flat Level
MTM Precision Sdn Bhd
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Contact MTM Precision today for RSK-2002 Precision Level enquiries and quotations in Malaysia.
11 Oct 2026