RSK-1502 vs RSK-1505 vs RSK-2002 Precision Level Comparison Malaysia
RSK-1502 vs RSK-1505 vs RSK-2002 Precision Level Comparison Malaysia
Introduction - Which RSK Precision Level Should You Choose?
Choosing the correct RSK Precision Flat Level is important for CNC machine leveling, lathe machine installation, milling machine setup, and industrial maintenance.
Three models available from MTM Precision Sdn Bhd are:
RSK-1502 Precision Level
RSK-1505 Precision Level
RSK-2002 Precision Level
Although these models serve similar industrial measurement purposes, they differ in measuring length and sensitivity.
Understanding these differences helps maintenance engineers, machine installation contractors, and precision engineering companies select an appropriate instrument.
This buying guide compares the three models and explains which factors matter when selecting a precision machine level in Malaysia.
RSK Precision Level Model Comparison
The following table summarises the nominal specifications of the three models.
SpecificationRSK-1502RSK-1505RSK-2002BrandRSKRSKRSKCountry of OriginJapanJapanJapanProduct TypePrecision Flat LevelPrecision Flat LevelPrecision Flat LevelNominal Length150 mm150 mm200 mmNominal Sensitivity0.02 mm/m0.05 mm/m0.02 mm/mMeasurement PrincipleSpirit BubbleSpirit BubbleSpirit BubblePrimary UseFine Machine LevelingGeneral Precision LevelingFine Machine Leveling
Important: The sensitivity values represent nominal inclination per scale division. They are not guarantees of overall measurement accuracy.
Users should confirm the applicable manufacturer's specifications and inspection requirements before selecting an instrument for critical work.
RSK-1502 Precision Level - 150mm 0.02mm/m
The RSK-1502 Precision Flat Level combines a 150 mm nominal length with 0.02 mm/m sensitivity.
It is suitable for applications requiring fine inclination readings on relatively compact measuring surfaces.
Typical Applications
CNC Machine Leveling
Lathe Machine Installation
Precision Machine Setup
Machine Tool Maintenance
Industrial Equipment Leveling
Why Choose RSK-1502?
The RSK-1502 may be appropriate when a machine manufacturer's procedure requires fine leveling sensitivity and the available reference surface is suitable for a 150 mm instrument.
For machine installation engineers working with restricted measuring spaces, the shorter body can offer practical advantages.
Best Selection Consideration: Choose the RSK-1502 when 0.02 mm/m sensitivity and a 150 mm measuring length match the required application.
RSK-1505 Precision Level - 150mm 0.05mm/m
The RSK-1505 Precision Flat Level has a 150 mm nominal length and 0.05 mm/m sensitivity.
Compared with the RSK-1502, it provides a less sensitive indication of inclination.
This does not necessarily make it inferior. Different machine leveling procedures require different measurement sensitivities.
Typical Applications
Industrial Machine Installation
Factory Maintenance
Workshop Equipment Leveling
Machine Tool Setup
Machinery Relocation Inspection
Why Choose RSK-1505?
The RSK-1505 can be considered when 0.05 mm/m sensitivity is sufficient for the machine manufacturer's specified leveling procedure.
Its 150 mm body may also be suitable for compact machine reference surfaces.
Best Selection Consideration: Choose the RSK-1505 when the application permits 0.05 mm/m sensitivity and requires a compact precision level.
RSK-2002 Precision Level - 200mm 0.02mm/m
The RSK-2002 Precision Flat Level features a 200 mm nominal measuring length and 0.02 mm/m sensitivity.
It offers the same nominal sensitivity as the RSK-1502 but has a longer measuring base.
Typical Applications
CNC Machine Installation
Lathe Machine Bed Leveling
Machine Tool Leveling
Precision Engineering Inspection
Industrial Equipment Setup
Why Choose RSK-2002?
The RSK-2002 may be useful when the measuring surface is sufficiently large to accommodate a 200 mm precision level.
Its 0.02 mm/m sensitivity allows fine inclination readings during suitable machine leveling procedures.
However, a longer precision level is not automatically more accurate.
Best Selection Consideration: Choose the RSK-2002 when 0.02 mm/m sensitivity and a 200 mm measuring base are appropriate for the required reference surface.
What Is the Difference Between 0.02mm/m and 0.05mm/m?
One of the most important differences between the three models is precision level sensitivity.
The RSK-1502 and RSK-2002 have a nominal sensitivity of 0.02 mm/m, while the RSK-1505 has 0.05 mm/m.
Sensitivity describes how much inclination corresponds to one scale division.
Sensitivity Comparison
Scale Division0.02 mm/m Level0.05 mm/m Level1 Division0.02 mm/m0.05 mm/m2 Divisions0.04 mm/m0.10 mm/m3 Divisions0.06 mm/m0.15 mm/m4 Divisions0.08 mm/m0.20 mm/m5 Divisions0.10 mm/m0.25 mm/m
A 0.02 mm/m precision level provides a finer indication of small inclination changes than a 0.05 mm/m precision level.
However, higher sensitivity does not automatically guarantee better measurement accuracy.
The correct choice depends on the required leveling tolerance, instrument condition, measurement procedure, and environmental conditions.
Does Higher Sensitivity Mean Better Accuracy?
This is a common question when comparing RSK Precision Levels.
Sensitivity and accuracy are related but different measurement concepts.
Sensitivity
Sensitivity indicates the inclination represented by one scale division.
For example, 0.02 mm/m is a finer sensitivity than 0.05 mm/m.
Accuracy
Accuracy concerns how closely an indicated measurement agrees with the actual measured quantity.
Instrument accuracy depends on factors such as manufacturing tolerances, calibration condition, and measurement technique.
Measurement Repeatability
Repeatability concerns how consistently an instrument produces readings under similar conditions.
For critical industrial applications, users should consider sensitivity, instrument tolerances, repeatability, and calibration requirements rather than selecting a precision level based on sensitivity alone.
150mm vs 200mm Precision Level - Which Length Is Better?
Another important difference is the measuring length.
The RSK-1502 and RSK-1505 have a nominal length of 150 mm.
The RSK-2002 has a nominal length of 200 mm.
Advantages of a 150mm Precision Level
A shorter precision level may be easier to position on compact machine reference surfaces.
Potential applications include:
Smaller machine tool reference areas
Restricted measurement locations
Compact industrial equipment
Precision workshop inspection
Advantages of a 200mm Precision Level
A longer precision level may be useful on sufficiently large and flat measuring surfaces.
Potential applications include:
Longer machine reference surfaces
Machine tool installation
Equipment leveling inspection
Suitable machine bed measurement positions
Important Selection Advice
The longer measuring base must contact a suitable reference surface.
If the surface is too small, uneven, or obstructed, a longer instrument may not be appropriate.
Choose the measuring length according to the machine's designated reference surface, not simply because a longer model appears more precise.
Which RSK Precision Level Is Suitable for CNC Machines?
CNC machine leveling is an important procedure during installation and maintenance.
A CNC machine must be supported and adjusted according to the manufacturer's requirements.
The choice of precision level depends on the specified leveling procedure.
RSK-1502 for CNC Machines
Consider the RSK-1502 when fine 0.02 mm/m sensitivity is required and the measuring surface can accommodate a 150 mm level.
RSK-1505 for CNC Machines
Consider the RSK-1505 when the machine manufacturer's leveling procedure permits 0.05 mm/m sensitivity.
RSK-2002 for CNC Machines
Consider the RSK-2002 when fine 0.02 mm/m sensitivity is required and the measuring surface is suitable for a 200 mm instrument.
Recommendation: Always check the CNC machine manufacturer's installation manual before choosing the required precision level sensitivity.
Which RSK Precision Level Is Suitable for Lathe Machines?
Lathe machine leveling requires careful measurement of designated machine reference surfaces.
Incorrect support adjustment may introduce unwanted distortion into the machine bed.
A precision level can help technicians assess leveling conditions during installation.
The RSK-1502 and RSK-2002 may be considered when finer inclination sensitivity is required.
The RSK-1505 may be appropriate when 0.05 mm/m sensitivity meets the machine manufacturer's procedure.
However, lathe bed twist cannot be determined from a single level reading.
Technicians should follow the specified measurement sequence and check all required reference positions.
Which RSK Precision Level Is Suitable for Milling Machines?
Milling machine leveling is another application for precision spirit levels.
The required instrument depends on the milling machine design, reference surface dimensions, and installation specifications.
For compact reference surfaces, a 150 mm RSK Precision Level may be convenient.
For suitable larger surfaces, the 200 mm RSK-2002 may be considered.
Users should verify the required sensitivity before purchasing.
RSK Precision Level for Factory Maintenance
Precision levels are also useful for industrial preventive maintenance.
Maintenance engineers may need to check machine leveling after:
Machine Relocation
Equipment Installation
Foundation Adjustment
Machine Support Replacement
Mechanical Maintenance
Machine Reinstallation
An RSK Precision Flat Level can assist with measuring inclination changes at designated reference positions.
However, precision leveling does not replace vibration analysis, shaft alignment, machine geometry inspection, or other maintenance procedures.
Common Mistakes When Buying a Precision Level
Mistake 1 - Choosing Only by Sensitivity
A more sensitive level is not automatically suitable for every machine.
Solution: Confirm the required sensitivity in the machine installation manual.
Mistake 2 - Ignoring Measuring Length
A precision level must fit the available reference surface.
Solution: Check whether a 150 mm or 200 mm body is appropriate.
Mistake 3 - Confusing Sensitivity with Accuracy
The sensitivity value does not represent guaranteed overall accuracy.
Solution: Review the manufacturer's accuracy specifications and calibration requirements.
Mistake 4 - Ignoring Instrument Condition
A damaged or poorly maintained precision level may produce unreliable readings.
Solution: Inspect the instrument and verify its calibration status when necessary.
Mistake 5 - Using an Incorrect Measuring Surface
Dirty, unstable, or unsuitable reference surfaces may affect measurement reliability.
Solution: Follow the machine manufacturer's recommended measurement locations and procedures.
RSK Precision Level Buying Checklist
Before purchasing an RSK Precision Level in Malaysia, consider the following questions.
1. What machine will you measure?
Identify whether the instrument is required for a CNC machine, lathe, milling machine, or other industrial equipment.
2. What sensitivity is required?
Determine whether the application requires 0.02 mm/m or 0.05 mm/m sensitivity.
3. What measuring length is suitable?
Check whether a 150 mm or 200 mm instrument fits the designated reference surface.
4. Is calibration documentation required?
Confirm the inspection or calibration documentation required for your application.
5. What is the intended measurement procedure?
Check the machine manufacturer's installation or maintenance instructions.
6. Which RSK model matches your requirements?
Compare the RSK-1502, RSK-1505, and RSK-2002 before selecting a model.
RSK Precision Level Supplier in Malaysia
MTM Precision Sdn Bhd supplies RSK Precision Flat Levels for industrial machine leveling and precision engineering applications.
Our available product range includes:
RSK-1502 Precision Flat Level
RSK-1505 Precision Flat Level
RSK-2002 Precision Flat Level
We support enquiries from industrial customers in Selangor, Kuala Lumpur, Johor, Penang, Melaka, Negeri Sembilan, Perak, Pahang, Kedah, Kelantan, Terengganu, Perlis, Sabah, and Sarawak.
Customers can contact MTM Precision for model selection assistance, product information, and quotations.
Frequently Asked Questions
What is the main difference between RSK-1502 and RSK-1505?
Both models have a 150 mm nominal length, but the RSK-1502 has 0.02 mm/m sensitivity, while the RSK-1505 has 0.05 mm/m sensitivity.
What is the difference between RSK-1502 and RSK-2002?
Both models have 0.02 mm/m sensitivity. The RSK-1502 has a nominal length of 150 mm, while the RSK-2002 has a nominal length of 200 mm.
Which RSK Precision Level is more sensitive?
The RSK-1502 and RSK-2002 have finer nominal sensitivity than the RSK-1505.
Is RSK-2002 more accurate than RSK-1502?
Not necessarily. Both have the same nominal sensitivity. Their overall accuracy depends on the applicable instrument specifications and measurement conditions.
Can RSK-1505 be used for CNC machine leveling?
Yes, provided 0.05 mm/m sensitivity meets the CNC machine manufacturer's leveling requirements.
Which RSK Precision Level should I buy for a lathe machine?
Choose according to the lathe manufacturer's required sensitivity, measuring positions, and reference surface dimensions.
Where can I buy RSK Precision Levels in Malaysia?
Contact MTM Precision Sdn Bhd for RSK-1502, RSK-1505, and RSK-2002 product enquiries and quotations.
Contact MTM Precision Sdn Bhd
Looking for an RSK Precision Flat Level in Malaysia?
MTM Precision Sdn Bhd supplies precision measuring instruments for CNC machine installation, lathe machine leveling, milling machine setup, factory maintenance, and precision engineering applications.
Available RSK Models:
RSK-1502 - 150 mm - 0.02 mm/m
RSK-1505 - 150 mm - 0.05 mm/m
RSK-2002 - 200 mm - 0.02 mm/m
MTM Precision Sdn Bhd
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Contact MTM Precision today for RSK Precision Level product selection and quotations in Malaysia.
11 Oct 2026