How to Check Metal Corrosion Using a Thickness Gauge Malaysia

How to Check Metal Corrosion Using a Thickness Gauge Malaysia

 

Complete Guide to Metal Corrosion Inspection and Remaining Wall Thickness Measurement

 

Metal corrosion thickness testing in Malaysia is an important part of industrial maintenance, equipment inspection and corrosion monitoring.

 

Metal components used in factories, manufacturing plants, industrial piping systems, storage tanks and machinery may experience material deterioration during operation.

 

Over time, corrosion can cause wall thinning, localised pitting and loss of material thickness.

 

If material loss is not identified and assessed appropriately, it may contribute to equipment damage, leakage or structural problems.

 

An ultrasonic thickness gauge can help maintenance technicians measure the remaining thickness of compatible metal components without cutting or dismantling the inspected equipment.

 

The Benetech GT-1202 Ultrasonic Thickness Gauge is a portable instrument that may be considered for suitable non-destructive metal thickness measurement applications.

 

In this guide, MTM Precision Sdn Bhd explains how to check possible corrosion-related wall thinning, measure remaining metal thickness, calculate an illustrative corrosion rate and recognise common measurement problems.

 

What Is Metal Corrosion?

 

Metal corrosion is a process in which a metal deteriorates through chemical or electrochemical interaction with its environment.

 

Corrosion can occur in many industrial environments, depending on the metal, moisture, temperature, chemical exposure and operating conditions.

 

Common examples include:

 

Carbon steel corrosion

 

Pipe wall corrosion

 

Storage tank corrosion

 

External corrosion on industrial equipment

 

Corrosion beneath damaged protective coatings

 

Localised pitting corrosion

 

Erosion-corrosion in industrial piping

 

Corrosion may affect the surface appearance of a component, but visual inspection alone may not reveal the remaining metal thickness.

 

For example, a pipe may appear relatively normal externally while internal corrosion has reduced the wall thickness.

 

This is one reason ultrasonic thickness measurement is useful in industrial corrosion monitoring.

 

How Does an Ultrasonic Thickness Gauge Help Check Corrosion?

 

An ultrasonic thickness gauge measures the thickness of suitable materials using ultrasonic sound waves.

 

The probe transmits an ultrasonic pulse into the material.

 

The pulse travels through the metal, reflects from the opposite boundary and returns to the probe.

 

The instrument calculates thickness using the ultrasonic travel time and the selected material sound velocity.

 

For a conventional pulse-echo measurement:

 

Thickness = Sound Velocity × Travel Time ÷ 2

 

For ordinary carbon steel, approximately 5,900 m/s is a commonly used reference sound velocity.

 

However, the correct velocity should be verified for the material being inspected.

 

By measuring metal thickness at selected locations and comparing readings with reliable reference values, technicians may identify possible wall thinning.

 

Important: An ultrasonic thickness gauge measures material thickness. It does not directly identify the chemical cause of corrosion, detect every form of corrosion or automatically determine whether equipment is safe.

 

Why Is Remaining Wall Thickness Important?

 

Remaining wall thickness is the thickness of material still present at an inspected location.

 

Industrial equipment may be manufactured with a specified nominal thickness.

 

Over time, corrosion or erosion may reduce the actual thickness.

 

For example, a steel pipe may have a nominal wall thickness of 8.00 mm.

 

An inspection may produce a measured thickness of 7.50 mm.

 

The difference is:

 

8.00 mm - 7.50 mm = 0.50 mm

 

However, this does not automatically mean that 0.50 mm of material has been lost through corrosion.

 

Actual initial thickness may differ from nominal thickness because of manufacturing tolerances.

 

A reliable assessment should consider original measurements, material specifications, inspection history and measurement uncertainty.

 

Common Industrial Applications for Corrosion Thickness Testing

 

1. Industrial Pipe Corrosion Monitoring

 

Metal pipes may experience internal or external corrosion during operation.

 

Ultrasonic thickness testing can help maintenance teams measure selected pipe wall locations.

 

Applications include compatible metal piping in factories, industrial water systems and process facilities.

 

2. Storage Tank Wall Thickness Inspection

 

Metal storage tanks may experience corrosion depending on their contents and environmental conditions.

 

Thickness measurements can support periodic tank condition assessment.

 

3. Steel Structure Inspection

 

Certain steel components may require thickness assessment where corrosion-related material loss is suspected.

 

However, the appropriate inspection method depends on component geometry and structural requirements.

 

4. Industrial Machinery Inspection

 

Selected metal equipment components may be inspected for thickness changes where ultrasonic measurement is suitable.

 

5. Marine Metal Corrosion Monitoring

 

Marine environments can expose metal structures to moisture and salts.

 

Ultrasonic thickness measurement may support suitable marine maintenance inspections.

 

Regulated marine surveys may require approved equipment, qualified personnel and specific inspection procedures.

 

Benetech GT-1202 for Metal Corrosion Thickness Measurement

 

The Benetech GT-1202 Ultrasonic Thickness Gauge is intended for portable ultrasonic thickness measurement.

 

It may be considered for compatible metal inspection applications involving:

 

Steel pipe wall thickness

 

Metal storage tank walls

 

Steel plates

 

Industrial metal components

 

Selected corrosion monitoring locations

 

Factory maintenance inspection

 

Before selecting the GT-1202, confirm that the material, expected thickness, surface condition and probe requirements are compatible with the instrument.

 

Particular care is necessary when measuring heavily corroded or pitted surfaces.

 

A conventional thickness gauge may not reliably detect the deepest localised pit or the minimum remaining thickness over a larger inspection area.

 

For critical corrosion inspection, a specialised corrosion thickness gauge, ultrasonic flaw detector or other appropriate inspection technique may be required.

 

How to Check Metal Corrosion Using a Thickness Gauge

 

The following procedure describes a general approach to ultrasonic thickness measurement for corrosion monitoring.

 

Step 1 - Identify the Metal and Inspection Objective

 

Determine the material being inspected.

 

Examples include carbon steel, stainless steel or other compatible metals.

 

Identify whether the purpose is:

 

Establishing baseline thickness

 

Monitoring possible corrosion

 

Investigating suspected wall thinning

 

Comparing previous inspection results

 

Supporting preventive maintenance

 

The inspection objective helps determine the appropriate measurement procedure.

 

Step 2 - Review Existing Thickness Information

 

Where available, review:

 

Original material specifications

 

Previous inspection records

 

Baseline thickness measurements

 

Pipe or tank drawings

 

Known corrosion history

 

Applicable inspection requirements

 

Historical thickness records can be more useful than nominal thickness alone when evaluating material loss.

 

Step 3 - Select Suitable Inspection Locations

 

Choose measurement points based on the equipment configuration and expected damage mechanisms.

 

Potential locations include:

 

Areas with visible corrosion

 

Pipe low points

 

Locations exposed to moisture

 

Pipe elbows and bends

 

Areas with damaged coatings

 

Storage tank sections with known corrosion history

 

Previously identified inspection points

 

Inspection locations should follow a suitable inspection plan rather than relying only on visual appearance.

 

Step 4 - Prepare the Metal Surface

 

Clean the selected area sufficiently to obtain reliable ultrasonic probe contact.

 

Remove loose rust, dirt or scale where necessary.

 

Avoid unnecessary removal of sound base metal.

 

For severe corrosion or deep pitting, specialised surface preparation and inspection procedures may be needed.

 

Step 5 - Verify the Thickness Gauge

 

Before measuring, verify the instrument using a suitable reference block or known-thickness sample.

 

For the Benetech GT-1202, follow the manufacturer's instructions for probe connection, verification and measurement settings.

 

If the instrument produces unstable or incorrect readings on the reference sample, investigate the problem before continuing.

 

Step 6 - Set the Correct Material Sound Velocity

 

Select the appropriate ultrasonic sound velocity for the metal.

 

For ordinary carbon steel, approximately 5,900 m/s is a commonly used starting reference.

 

However, actual velocity can vary.

 

Use an appropriate reference sample to verify the setting.

 

Step 7 - Apply Ultrasonic Couplant

 

Apply suitable ultrasonic coupling gel to the inspection area.

 

The couplant helps transmit ultrasonic energy between the probe and metal surface.

 

Poor coupling may result in unstable readings or measurement failure.

 

Step 8 - Measure the Remaining Thickness

 

Position the probe correctly and obtain a stable thickness reading.

 

Record the displayed value together with the inspection location.

 

For corrosion monitoring, take measurements according to the defined inspection grid or procedure.

 

Step 9 - Repeat Measurements

 

Repeat measurements where required to assess consistency.

 

For suspected localised corrosion, additional nearby readings or specialised scanning techniques may be necessary.

 

Do not assume that one measurement represents the minimum thickness of an entire component.

 

Step 10 - Compare and Evaluate Results

 

Compare verified measurements with previous inspection data and applicable engineering criteria.

 

Significant changes should be investigated.

 

The final condition assessment may require qualified personnel, additional testing and relevant industry standards.

 

Example Metal Corrosion Thickness Inspection Record

 

A maintenance team may record measurements at several inspection points.

 

Inspection LocationExample ThicknessPoint A7.92 mmPoint B7.81 mmPoint C7.45 mmPoint D7.76 mmPoint E7.89 mm

 

Note: These values are hypothetical examples and are not actual Benetech GT-1202 measurement results.

 

Point C has the lowest displayed thickness among the five locations.

 

This may justify further inspection, but it does not automatically prove that Point C contains the deepest corrosion damage.

 

The result should be verified and assessed using the appropriate inspection procedure.

 

How to Calculate Corrosion Rate from Thickness Measurements

 

A simplified average corrosion-related wall-loss rate can be calculated when reliable thickness measurements are available from different inspection dates.

 

The basic formula is:

 

Average Wall-Loss Rate = (Initial Thickness - Current Thickness) / Time Interval

 

For example:

 

Initial verified thickness: 8.00 mm

 

Current verified thickness: 7.40 mm

 

Time interval: 3 years

 

Calculation:

 

(8.00 - 7.40) / 3 = 0.20 mm/year

 

The illustrative average wall-loss rate is 0.20 mm per year.

 

However, this calculation assumes that the measurements are comparable, taken at the same location and sufficiently reliable.

 

Actual corrosion behaviour may not be constant over time.

 

Corrosion rate assessment should also consider measurement uncertainty, operating conditions, damage mechanisms and the applicable inspection standard.

 

Can a Thickness Gauge Detect Pitting Corrosion?

 

Pitting corrosion is a form of localised corrosion that creates small cavities or pits in a metal surface.

 

Pitting can be difficult to evaluate using ordinary point thickness measurements.

 

A conventional ultrasonic thickness gauge may miss narrow or isolated pits between measurement locations.

 

It may also have difficulty measuring highly irregular or severely pitted back-wall surfaces.

 

For suspected pitting corrosion, appropriate methods may include:

 

More closely spaced thickness measurements

 

Suitable corrosion inspection probes

 

Ultrasonic scanning

 

Ultrasonic flaw detection

 

Other specialised non-destructive testing techniques

 

The correct method depends on the material, component and inspection requirements.

 

Important: The Benetech GT-1202 should not be represented as a dedicated pitting corrosion detection system without manufacturer confirmation.

 

Metal Corrosion vs Coating Thickness Measurement

 

Industrial maintenance personnel sometimes confuse metal thickness measurement with protective coating thickness measurement.

 

These are different inspection tasks.

 

InstrumentMain MeasurementUltrasonic Thickness GaugeThickness of compatible materialCoating Thickness GaugeThickness of compatible paint or protective coatingUltrasonic Flaw DetectorDetection or characterisation of certain material discontinuitiesCorrosion Monitoring SystemMonitoring selected corrosion-related conditions or parameters

 

For example, an industrial steel tank may have a protective paint coating.

 

A coating thickness gauge may be used to measure the paint layer.

 

An ultrasonic thickness gauge may be used to measure the underlying steel thickness, subject to instrument capability and inspection procedure.

 

These instruments may complement one another in industrial maintenance.

 

Common Problems During Corrosion Thickness Testing

 

Problem 1 - Thickness Reading Is Unstable

 

Possible causes include poor coupling, surface roughness, probe movement or unsuitable measurement conditions.

 

Solution: Check the surface, couplant, probe contact and instrument settings.

 

Problem 2 - No Reading on Corroded Metal

 

Heavy corrosion, rough surfaces or poor ultrasonic transmission may prevent a reliable measurement.

 

Solution: Improve surface preparation where appropriate and consider a specialised inspection method.

 

Problem 3 - Thickness Reading Appears Too High

 

Incorrect sound velocity, unsuitable echo interpretation or measurement configuration may produce unexpected readings.

 

Solution: Verify the instrument using a suitable reference sample and check the measurement settings.

 

Problem 4 - Thickness Reading Appears Too Low

 

A low reading may reflect actual material loss, local geometry, incorrect settings or measurement uncertainty.

 

Solution: Repeat the measurement and investigate the location before drawing conclusions.

 

Problem 5 - Different Readings at Nearby Locations

 

Possible causes include actual thickness variation, localised corrosion, manufacturing tolerances or measurement conditions.

 

Solution: Follow an appropriate inspection grid and evaluate the results systematically.

 

Problem 6 - Difficulty Measuring Through Paint

 

Protective coatings may affect conventional ultrasonic thickness measurements.

 

Solution: Confirm whether the instrument supports the required measurement technique. Do not assume the GT-1202 automatically compensates for coatings.

 

How to Improve Corrosion Thickness Measurement Reliability

 

For better measurement consistency:

 

Use the correct material sound velocity.

 

Verify the instrument before inspection.

 

Select a suitable ultrasonic probe.

 

Prepare the measurement surface properly.

 

Apply appropriate ultrasonic couplant.

 

Maintain consistent probe positioning.

 

Record the exact inspection locations.

 

Repeat measurements when necessary.

 

Compare readings with reliable historical data.

 

Follow applicable inspection standards and procedures.

 

For critical equipment, use qualified inspection personnel and appropriate engineering assessment methods.

 

Preventive Maintenance Using Ultrasonic Thickness Testing

 

A structured corrosion monitoring programme may help industrial facilities identify changes in material thickness.

 

Baseline Inspection

 

Establish initial thickness measurements at defined locations.

 

Periodic Inspection

 

Repeat measurements at intervals based on the equipment's risk and inspection requirements.

 

Thickness Trend Analysis

 

Compare verified readings from different inspection dates.

 

Corrosion Assessment

 

Investigate significant changes and assess the likely damage mechanisms.

 

Maintenance Planning

 

Use inspection findings to support decisions about additional testing, repair or replacement.

 

A portable ultrasonic thickness gauge can provide useful measurement data within this process.

 

However, it should not replace a complete equipment integrity management programme.

 

Industrial Corrosion Monitoring Applications Across Malaysia

 

Selangor and Kuala Lumpur

 

Manufacturing plants, industrial piping, mechanical engineering and factory maintenance.

 

Johor

 

Industrial facilities, steel fabrication, process equipment and marine-related maintenance.

 

Penang

 

Precision manufacturing, engineering facilities and industrial quality control.

 

Melaka and Negeri Sembilan

 

Factory maintenance, industrial equipment inspection and mechanical engineering.

 

Perak, Pahang, Kedah, Kelantan, Terengganu and Perlis

 

Industrial infrastructure, metal equipment maintenance and suitable corrosion monitoring applications.

 

Sabah and Sarawak

 

Industrial facilities, marine-related equipment and pipeline maintenance applications.

 

MTM Precision supports industrial testing instrument enquiries from customers throughout Malaysia.

 

Frequently Asked Questions

 

Can an ultrasonic thickness gauge detect metal corrosion?

 

An ultrasonic thickness gauge measures material thickness. It can help identify possible corrosion-related wall thinning, but it does not directly determine the corrosion mechanism.

 

Can Benetech GT-1202 measure corroded steel?

 

The Benetech GT-1202 may be suitable for certain corroded steel thickness measurements when the material, surface condition, probe and inspection method are compatible.

 

Can a thickness gauge detect internal corrosion?

 

It may identify wall thinning associated with internal corrosion at measured locations. However, it may not detect every localised corrosion defect.

 

What is remaining wall thickness?

 

Remaining wall thickness is the material thickness measured at an inspection location after any material loss that may have occurred.

 

How is corrosion rate calculated?

 

A simplified average wall-loss rate is calculated by dividing the difference between comparable thickness measurements by the time interval between inspections.

 

Can GT-1202 detect pitting corrosion?

 

A conventional thickness gauge may not reliably identify narrow or isolated pits. Specialised inspection methods may be required.

 

Can ultrasonic thickness testing be performed through paint?

 

This depends on the instrument's measurement capabilities, coating condition and inspection procedure. Coating compensation should not be assumed without manufacturer confirmation.

 

How often should metal corrosion thickness be checked?

 

Inspection intervals depend on operating conditions, damage mechanisms, inspection history, risk assessment and applicable standards.

 

Where can I buy a corrosion thickness gauge in Malaysia?

 

Contact MTM Precision Sdn Bhd for ultrasonic thickness gauge product enquiries, quotation and availability confirmation.

 

Benetech GT-1202 Ultrasonic Thickness Gauge Supplier Malaysia

 

Choosing a suitable ultrasonic thickness gauge for corrosion monitoring requires understanding the metal material, expected thickness, surface condition and inspection requirements.

 

The Benetech GT-1202 Ultrasonic Thickness Gauge may be considered for compatible industrial metal thickness measurement applications.

 

MTM Precision Sdn Bhd supplies industrial testing and measuring instruments for factories, maintenance contractors, engineering companies and industrial inspection customers in Malaysia.

 

Customers can contact our team for product information, quotation and availability confirmation.

 

For faster assistance, provide:

 

Metal material

 

Expected thickness range

 

Surface condition

 

Inspection application

 

Instrument model

 

Calibration requirements

 

Contact MTM Precision Malaysia

 

Looking for a Benetech GT-1202 Ultrasonic Thickness Gauge for corrosion monitoring, pipe inspection, tank maintenance or industrial testing?

 

MTM Precision Sdn Bhd

 

Showroom & Service Centre

 

No. 29-1 & 2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Tel: 03-8080 7172

 

WhatsApp: +6016-660 7346

 

Email: mtmpre@yahoo.com

 

Website: www.mtmpre.com.my

 

Business Hours: Monday to Friday, 9:00 AM - 6:00 PM

 

For faster assistance, send us the material type, expected thickness, corrosion condition and inspection application through WhatsApp.

 

You may also send photos of the metal component or corroded inspection area so our team can better understand your requirements.

 

MTM Precision - Industrial Testing and Measuring Instruments Malaysia


 

15 Oct 2026