How to Measure Tank Wall Thickness Malaysia

How to Measure Tank Wall Thickness Malaysia

 

Complete Guide to Ultrasonic Storage Tank Thickness Inspection and Corrosion Monitoring

 

Tank wall thickness measurement in Malaysia is an important part of industrial storage tank inspection, preventive maintenance and corrosion monitoring.

 

Industrial storage tanks are widely used in manufacturing facilities, water treatment plants, chemical processing facilities, engineering plants and other industrial environments.

 

Depending on the tank material, stored product and operating conditions, metal tank walls may experience internal corrosion, external corrosion, localised pitting, erosion or general wall thinning.

 

These conditions may reduce the remaining metal thickness and require further inspection or engineering assessment.

 

An ultrasonic thickness gauge can help maintenance technicians measure the thickness of suitable tank wall materials from an accessible surface without cutting or damaging the inspected component.

 

The Benetech GT-1202 Ultrasonic Thickness Gauge is a portable instrument that may be considered for compatible non-destructive material thickness measurement applications.

 

In this guide, MTM Precision Sdn Bhd explains how ultrasonic tank wall thickness measurement works, how to select inspection locations, how to record thickness readings and how to improve inspection reliability.

 

What Is Tank Wall Thickness Measurement?

 

Tank wall thickness measurement is the process of determining the actual material thickness at selected locations on a storage tank.

 

For suitable metal tanks, ultrasonic thickness testing is commonly used because it can provide measurements when only one side of the material is accessible.

 

The instrument transmits ultrasonic sound waves into the material through a suitable probe.

 

The sound waves reflect from the opposite material boundary and return to the probe.

 

The thickness gauge calculates the material thickness based on the ultrasonic travel time and the selected sound velocity.

 

The basic pulse-echo formula is:

 

Thickness = Sound Velocity × Travel Time ÷ 2

 

For ordinary carbon steel, approximately 5,900 m/s is a commonly used longitudinal sound velocity reference.

 

However, the actual sound velocity should be verified for the material being inspected.

 

Why Is Storage Tank Thickness Inspection Important?

 

Metal storage tanks may experience material deterioration over time.

 

The rate and location of deterioration depend on the tank design, material, stored product, operating temperature, moisture exposure and environmental conditions.

 

Common concerns include:

 

Internal corrosion

 

External corrosion

 

Corrosion beneath damaged coatings

 

Tank bottom corrosion

 

Localised pitting

 

General wall thinning

 

Material degradation

 

Thickness inspection can provide useful information about the remaining metal thickness at selected locations.

 

However, ultrasonic thickness readings alone do not determine whether a tank is safe for continued operation.

 

Professional tank integrity assessment may require engineering calculations, other inspection methods and applicable industry standards.

 

Types of Industrial Tanks That May Require Thickness Inspection

 

1. Steel Water Storage Tanks

 

Steel water tanks may experience corrosion depending on water chemistry, protective coatings and environmental exposure.

 

Ultrasonic thickness testing can support inspection of compatible steel tank walls.

 

2. Industrial Process Tanks

 

Process tanks may contain liquids or other materials that affect the tank's internal surfaces.

 

Suitable ultrasonic thickness measurement may help monitor selected wall locations.

 

3. Chemical Storage Tanks

 

Chemical storage tanks may require specialised inspection procedures based on the stored chemicals, tank materials and safety requirements.

 

Ultrasonic thickness testing may form part of an appropriate inspection programme.

 

4. Fuel and Petroleum Storage Tanks

 

Certain metal fuel storage tanks may require periodic thickness inspection.

 

Inspection of regulated tanks should follow applicable requirements and be performed by appropriately qualified personnel.

 

5. Industrial Metal Vessels

 

Some metal vessels and related equipment may be suitable for ultrasonic wall thickness measurement.

 

However, pressure vessels and other safety-critical equipment may require specialised inspection methods and regulatory compliance.

 

Benetech GT-1202 for Storage Tank Wall Thickness Measurement

 

The Benetech GT-1202 Ultrasonic Thickness Gauge is intended for portable ultrasonic material thickness measurement.

 

It may be considered for compatible tank wall inspection applications involving:

 

Carbon steel tank walls

 

Suitable metal storage tanks

 

Industrial water tanks

 

Metal process equipment

 

Selected corrosion monitoring locations

 

Factory maintenance inspection

 

Before using the GT-1202 for tank inspection, confirm:

 

The tank material is compatible with the instrument.

 

The expected wall thickness is within the supported measurement range.

 

The probe is suitable for the material and surface condition.

 

The measurement surface can provide adequate ultrasonic coupling.

 

The operating temperature is within the instrument and probe limits.

 

The inspection requirements can be met by the selected instrument.

 

Important: Do not assume that the GT-1202 is suitable for every tank material, thickness, coating or inspection standard without checking the manufacturer's specifications.

 

How to Measure Tank Wall Thickness Using an Ultrasonic Thickness Gauge

 

The following is a general procedure for compatible ultrasonic tank wall thickness measurement.

 

Step 1 - Identify the Tank Material

 

Determine whether the tank is made from carbon steel, stainless steel or another compatible material.

 

Different materials may require different ultrasonic sound velocity settings.

 

For accurate measurement, verify the material velocity using a suitable reference sample.

 

Step 2 - Review Tank Information

 

Before inspection, review available information such as:

 

Tank design drawings

 

Material specifications

 

Original plate thickness

 

Previous inspection records

 

Known corrosion history

 

Stored product information

 

Applicable inspection requirements

 

This information helps determine the inspection objective.

 

Step 3 - Establish Safe Inspection Conditions

 

Before approaching the tank, follow the site's safety procedures.

 

Depending on the application, relevant controls may include:

 

Work permits

 

Hazardous atmosphere assessment

 

Appropriate personal protective equipment

 

Equipment isolation

 

Safe access arrangements

 

Fall protection

 

Confined-space procedures where applicable

 

Important: Never enter a storage tank or confined space solely to obtain thickness readings without the required authorisation, atmospheric testing, rescue arrangements and applicable safety procedures.

 

External ultrasonic measurement may avoid the need for internal access in some applications, but it does not eliminate all inspection hazards.

 

Step 4 - Select Tank Inspection Locations

 

Choose measurement points based on the tank design, expected damage mechanisms and inspection plan.

 

Potential locations include:

 

Lower shell courses

 

Areas with visible external corrosion

 

Locations exposed to moisture

 

Areas with damaged protective coatings

 

Previously identified corrosion locations

 

Regions near suitable structural features

 

Defined inspection grid locations

 

Inspection point selection should follow the applicable procedure rather than relying only on visible corrosion.

 

Step 5 - Prepare the Measurement Surface

 

Clean the selected area sufficiently to obtain reliable probe contact.

 

Remove loose dirt, rust or scale where necessary.

 

Avoid excessive grinding or unnecessary removal of sound base metal.

 

Heavily corroded or irregular surfaces may require specialised inspection techniques.

 

Step 6 - Verify the Ultrasonic Thickness Gauge

 

Check the instrument using a suitable reference block or known-thickness sample.

 

For the Benetech GT-1202, follow the manufacturer's verification procedure.

 

Confirm the probe connection, measurement settings and reading stability.

 

Step 7 - Set the Correct Sound Velocity

 

Select the appropriate ultrasonic sound velocity for the tank material.

 

For ordinary carbon steel, approximately 5,900 m/s is a commonly used starting reference.

 

However, the correct value should be verified for the actual material.

 

Step 8 - Apply Ultrasonic Couplant

 

Apply suitable ultrasonic coupling gel to the selected measurement point.

 

The couplant helps transmit ultrasonic energy between the probe and tank wall.

 

Insufficient coupling may produce unstable readings or prevent measurement.

 

Step 9 - Position the Probe

 

Place the probe correctly on the prepared tank surface.

 

Maintain stable contact and follow the manufacturer's operating instructions.

 

For curved or irregular surfaces, probe suitability and positioning may affect measurement reliability.

 

Step 10 - Record Thickness Readings

 

Obtain stable thickness readings and record the results at the defined inspection locations.

 

Repeat measurements where required.

 

Step 11 - Evaluate the Results

 

Compare verified readings with relevant baseline data, previous inspection records and applicable engineering criteria.

 

Unexpected results should be investigated before maintenance decisions are made.

 

Where Should Tank Wall Thickness Measurements Be Taken?

 

A tank inspection programme may divide the tank into defined inspection zones.

 

The correct locations depend on tank design, material, operating conditions and expected damage mechanisms.

 

Tank Shell

 

The tank shell may be inspected at selected locations across different shell courses.

 

Lower Tank Shell

 

The lower shell may require attention where corrosion mechanisms or operating conditions justify inspection.

 

Tank Roof

 

Certain metal tank roof components may require thickness inspection where access and measurement conditions are suitable.

 

Tank Bottom

 

Tank bottoms may experience corrosion, but conventional external point thickness measurement may not provide access to the entire bottom plate.

 

Specialised inspection methods may be required.

 

Areas with Visible Corrosion

 

Locations with visible corrosion or coating damage may warrant further inspection.

 

However, visual appearance alone does not establish the extent of material loss.

 

Example Storage Tank Thickness Inspection Record

 

A maintenance technician may record thickness measurements from several defined tank locations.

 

Tank LocationExample ThicknessShell Course 1 - Point A9.82 mmShell Course 1 - Point B9.76 mmShell Course 2 - Point A8.94 mmShell Course 2 - Point B8.88 mmShell Course 3 - Point A7.92 mm

 

Note: These values are hypothetical examples for explaining inspection documentation. They are not actual Benetech GT-1202 measurement results.

 

Different shell courses may have different design thicknesses.

 

Therefore, readings from different courses should not be directly compared without considering the tank design and material specifications.

 

How to Monitor Tank Wall Corrosion Over Time

 

Ultrasonic thickness measurement can support corrosion monitoring when measurements are collected consistently.

 

A monitoring programme may include:

 

Baseline Inspection

 

Record initial verified thickness measurements at defined locations.

 

Periodic Inspection

 

Repeat measurements according to an appropriate inspection schedule.

 

Thickness Trend Analysis

 

Compare current measurements with previous readings from the same locations.

 

Corrosion Assessment

 

Investigate significant changes and evaluate possible material loss.

 

Maintenance Planning

 

Use the inspection findings to support decisions about additional inspection, repair or replacement.

 

Inspection intervals should be established using appropriate engineering assessment and applicable requirements.

 

Example Tank Wall Corrosion Rate Calculation

 

A simplified average wall-loss rate can be calculated when reliable thickness measurements are available from different inspection dates.

 

The formula is:

 

Average Wall-Loss Rate = (Previous Thickness - Current Thickness) / Time Interval

 

For example:

 

Previous verified thickness: 10.00 mm

 

Current verified thickness: 9.40 mm

 

Time interval: 4 years

 

Calculation:

 

(10.00 - 9.40) / 4 = 0.15 mm/year

 

The illustrative average wall-loss rate is 0.15 mm per year.

 

However, actual corrosion rates may vary over time.

 

This calculation assumes that the measurements are comparable and sufficiently reliable.

 

Professional corrosion assessment may require additional inspection data, engineering calculations and relevant standards.

 

Common Problems During Tank Wall Thickness Measurement

 

Problem 1 - Unstable Thickness Readings

 

Possible causes include poor probe contact, insufficient couplant, surface roughness or unsuitable instrument settings.

 

Recommended Action: Check the probe, couplant, surface condition and measurement configuration.

 

Problem 2 - No Thickness Reading

 

The instrument may not obtain a reliable ultrasonic signal.

 

Recommended Action: Verify the instrument using a suitable reference block and inspect the probe connection and test surface.

 

Problem 3 - Unexpectedly Low Thickness

 

A low reading may indicate actual material loss or a measurement problem.

 

Recommended Action: Repeat the measurement and investigate the location before drawing conclusions.

 

Problem 4 - Different Readings Across Tank Sections

 

Differences may result from original plate thickness, manufacturing tolerances, corrosion or measurement uncertainty.

 

Recommended Action: Compare readings with the correct design information and inspection records.

 

Problem 5 - Difficulty Measuring Through Paint

 

Protective coatings may affect conventional ultrasonic thickness measurement.

 

Recommended Action: Confirm whether the instrument supports the required measurement method. Do not assume the GT-1202 automatically compensates for coatings.

 

Problem 6 - Severe Surface Corrosion

 

Heavy rust, scale or pitting may interfere with ultrasonic transmission.

 

Recommended Action: Use appropriate surface preparation and consider specialised inspection methods where necessary.

 

Ultrasonic Thickness Gauge vs Other Tank Inspection Methods

 

Different inspection methods provide different information.

 

Inspection MethodMain PurposeUltrasonic Thickness GaugeMeasures local material thicknessVisual InspectionIdentifies visible surface conditionsCoating Thickness GaugeMeasures compatible protective coating thicknessUltrasonic Flaw DetectorDetects or characterises certain material discontinuitiesMagnetic Flux Leakage TestingUsed in suitable applications to detect metal loss over inspected areasRadiographic TestingProvides imaging-based inspection information

 

An ultrasonic thickness gauge is useful for local thickness measurement.

 

However, it does not replace all inspection methods required for a complete tank integrity assessment.

 

Important Tank Inspection Standards and Requirements

 

Professional tank inspection may involve recognised standards and regulatory requirements.

 

Depending on the tank type and application, relevant references may include:

 

API 653 for certain aboveground storage tank inspection, repair, alteration and reconstruction activities

 

API 650 for applicable welded storage tank design and construction

 

API 510 for applicable pressure vessel inspection

 

ISO 16809 for ultrasonic thickness measurement principles and procedures

 

The applicability of any standard depends on the equipment and inspection scope.

 

These standards do not automatically establish that a particular portable thickness gauge is approved for every regulated inspection.

 

For critical applications, use qualified inspection personnel and appropriate procedures.

 

How to Choose an Ultrasonic Thickness Gauge for Tank Inspection

 

Before purchasing an ultrasonic thickness gauge for storage tank inspection in Malaysia, consider:

 

Tank Material

 

Confirm compatibility with carbon steel, stainless steel or the intended material.

 

Expected Thickness Range

 

Check the minimum and maximum wall thickness to be measured.

 

Measurement Accuracy

 

Select an instrument that meets the inspection requirements.

 

Probe Compatibility

 

Consider tank curvature, surface condition and temperature.

 

Data Recording

 

Determine whether stored readings or electronic reporting are required.

 

Calibration Requirements

 

Confirm whether calibration documentation or traceable verification is necessary.

 

Inspection Standards

 

Check whether the application requires a specific instrument capability or approved inspection procedure.

 

Technical Support

 

Choose a supplier that can assist with product information, quotations and technical enquiries.

 

Industrial Tank Thickness Measurement Applications Across Malaysia

 

Selangor and Kuala Lumpur

 

Manufacturing facilities, industrial storage tanks, engineering plants and factory maintenance.

 

Johor

 

Industrial facilities, chemical processing, steel fabrication and marine-related maintenance.

 

Penang

 

Manufacturing plants, engineering facilities and industrial quality control.

 

Melaka and Negeri Sembilan

 

Factory maintenance, industrial equipment inspection and mechanical engineering.

 

Perak, Pahang, Kedah, Kelantan, Terengganu and Perlis

 

Industrial infrastructure, water treatment facilities and suitable tank maintenance applications.

 

Sabah and Sarawak

 

Industrial facilities, storage equipment and marine-related maintenance.

 

MTM Precision supports industrial testing instrument enquiries from customers throughout Malaysia.

 

Frequently Asked Questions

 

What is tank wall thickness measurement?

 

Tank wall thickness measurement is the process of measuring the actual material thickness at selected tank locations, commonly using ultrasonic testing for suitable metal tanks.

 

Can Benetech GT-1202 measure steel tank thickness?

 

The Benetech GT-1202 may be considered for compatible steel tank wall thickness measurement when the material, thickness, surface condition and probe configuration are suitable.

 

Can ultrasonic thickness testing detect tank corrosion?

 

It can help identify possible wall thinning associated with corrosion at measured locations. It does not directly determine the corrosion mechanism or detect every type of defect.

 

Can GT-1202 measure tank bottoms?

 

Measurement may be possible at accessible locations under suitable conditions, but complete tank bottom inspection often requires specialised methods and procedures.

 

What sound velocity should be used for carbon steel tanks?

 

Approximately 5,900 m/s is a commonly used starting reference for ordinary carbon steel, but the correct value should be verified.

 

Can ultrasonic thickness testing be performed through paint?

 

This depends on the instrument's measurement method, coating condition and inspection requirements. Coating compensation should not be assumed without manufacturer confirmation.

 

How often should storage tanks be inspected?

 

Inspection intervals depend on tank type, operating conditions, corrosion history, risk assessment and applicable standards.

 

Can thickness readings determine whether a tank is safe?

 

No. Thickness measurements provide inspection data, but tank integrity assessment may require engineering calculations, additional testing and qualified personnel.

 

Where can I enquire about an ultrasonic tank thickness gauge in Malaysia?

 

Contact MTM Precision Sdn Bhd for product information, quotation and availability confirmation.

 

Benetech GT-1202 Ultrasonic Thickness Gauge Supplier Malaysia

 

Selecting the right ultrasonic thickness gauge for tank wall inspection requires understanding the tank material, expected thickness, surface condition and inspection requirements.

 

The Benetech GT-1202 Ultrasonic Thickness Gauge may be considered for compatible industrial metal thickness measurement applications.

 

MTM Precision Sdn Bhd supplies industrial testing and measuring instruments to Malaysian factories, engineering companies, maintenance contractors and industrial inspection customers.

 

For assistance, provide:

 

Tank material

 

Expected wall thickness

 

Tank type

 

Surface condition

 

Inspection application

 

Calibration requirements

 

Contact our team for product information and quotation.

 

Contact MTM Precision Malaysia

 

Looking for a Benetech GT-1202 Ultrasonic Thickness Gauge for storage tank wall thickness measurement, corrosion monitoring or industrial maintenance?

 

MTM Precision Sdn Bhd

 

Showroom & Service Centre

 

No. 29-1 & 2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Tel: 03-8080 7172

 

WhatsApp: +6016-660 7346

 

Email: mtmpre@yahoo.com

 

Website: www.mtmpre.com.my

 

Business Hours: Monday to Friday, 9:00 AM - 6:00 PM

 

For faster assistance, send us the tank type, material, expected thickness range and inspection application through WhatsApp.

 

You may also send photos of the tank or inspection area so our team can better understand your requirements.

 

MTM Precision - Industrial Testing and Measuring Instruments Malaysia


 

15 Oct 2026