DITRON H01 vs H02 Digital Thickness Gauges | Paper and Plastic Film Measurement Malaysia

Choosing a Digital Thickness Gauge for Thin Materials


The DITRON H01 and H02 Digital Thickness Gauges measure material thickness between upper and lower contact faces. The catalogue identifies plastic film, paper and thin pieces as intended applications.


Both series offer 12.7mm and 25.4mm measuring ranges. The main difference is resolution and stated accuracy: H01 models provide 0.01mm resolution, while H02 models provide 0.001mm resolution.


For packaging manufacturers, printing businesses and quality control teams in Malaysia, selection should consider material thickness, required tolerance, contact access and whether the material compresses during measurement.


KEY FEATURES


Direct Digital Reading


The display shows the separation between the measuring contacts, providing a direct thickness reading when the material is seated correctly.


Lever-Operated Contact Opening


The illustrated lever mechanism opens the measuring contacts for inserting and removing a sample. Operate the mechanism gently and follow the manufacturer’s instructions for applying contact.


Millimetre/Inch Conversion


The catalogue lists inch/mm conversion for working with metric and imperial thickness specifications.


Zero Function


The zero function establishes the reference reading. Clean the contact faces and check zero before measuring.


Manual Power On/Off


Manual power control is specified on the supplied catalogue page.


Aluminium and ABS Housing


The catalogue lists aluminium and ABS housing materials with a stainless steel probe.


MODEL SPECIFICATIONS


Model: H01-127

Measuring range: 0–12.7mm / 0.5in

Resolution: 0.01mm / 0.0005in

Accuracy: ±0.02mm


Model: H01-254

Measuring range: 0–25.4mm / 1in

Resolution: 0.01mm / 0.0005in

Accuracy: ±0.03mm


Model: H02-127

Measuring range: 0–12.7mm / 0.5in

Resolution: 0.001mm / 0.00005in

Accuracy: ±5µm, equivalent to ±0.005mm


Model: H02-254

Measuring range: 0–25.4mm / 1in

Resolution: 0.001mm / 0.00005in

Accuracy: ±7µm, equivalent to ±0.007mm


The supplied drawing also shows a 28mm horizontal reach dimension. Confirm the selected model’s dimensional drawing if measurement access from the sample edge is critical.


H01 VS H02: WHICH SERIES SHOULD YOU CHOOSE?


H01 for Applications Suited to 0.01mm Resolution


The H01 series is an option where a 0.01mm reading increment and the stated accuracy meet the inspection requirement.


Choose H01-127 for thicknesses within 12.7mm or H01-254 when additional measuring capacity is needed.


H02 for Finer Thickness Readings


The H02 series provides a 0.001mm display increment and better listed accuracy than the corresponding H01 models.


This finer resolution can help observe smaller differences between samples. However, material compression, surface texture and contact conditions must also be controlled.


Choose by Required Range


A larger range does not provide better accuracy. The 12.7mm models have better listed accuracy than the corresponding 25.4mm models.


Select sufficient capacity for the sample while considering the required measurement performance.


RESOLUTION IS DIFFERENT FROM ACCURACY


The H02-127 displays in 0.001mm increments but has a stated accuracy of ±0.005mm. It should not be described as having ±0.001mm accuracy.


For very thin film, compare the expected thickness and tolerance with the gauge accuracy. A fine display alone does not establish whether the instrument can reliably assess the required variation.


TYPICAL APPLICATIONS


Paper Thickness Checks


Measure accessible paper samples at selected positions to compare thickness variation. Keep the samples flat and use a consistent contact procedure.


Plastic Film Inspection


Check suitable film samples between the contact faces. Avoid folds, wrinkles and contamination that could increase the reading.


Packaging Material Comparison


Compare thin packaging pieces where the measuring range and contact arrangement suit the material.


Thin Sheet and Component Checks


The gauge may be considered for other thin pieces, subject to material behaviour, surface geometry and the inspection tolerance.


These applications are relevant to packaging, printing and manufacturing teams in Selangor, Penang, Johor and other industrial areas in Malaysia.


MEASURING SOFT OR COMPRESSIBLE MATERIALS


Paper, film and other flexible materials can respond differently to contact pressure.


The supplied page does not specify measuring force or contact face diameter. These details matter when comparing results between instruments or following a test method that requires defined pressure.


Do not assume compliance with a particular paper, film or textile testing standard from resolution and accuracy alone. Confirm the required force, contact geometry and procedure before selecting the gauge for standardised testing.


This instrument measures total thickness between its contacts. It does not separately measure a coating on a substrate.


BASIC MEASUREMENT WORKFLOW


1. Clean the contact faces.


Remove dust and residue from both measuring surfaces.


2. Check the reference.


Bring the contacts together gently and check zero according to the operating instructions.


3. Open the contacts.


Use the lever mechanism to provide clearance for the sample.


4. Position the material.


Place the intended measuring area between the contacts without folds or trapped debris.


5. Apply contact consistently.


Release the mechanism gently. Avoid adding hand pressure that could compress the sample.


6. Record and repeat.


Measure several positions where appropriate. Keep contact timing and sample handling consistent.


After measurement, recheck zero if the readings appear unusual or inconsistent.


CARE AND ROUTINE CHECKING


Protect the probe and contact faces from impact. Avoid dragging abrasive samples across the measuring surfaces.


If readings vary, check cleanliness, sample flatness, zero setting and compression before assuming an instrument fault.


Confirm battery requirements, supplied accessories and any calibration documentation when requesting a quotation; these details are not established by the supplied page.


FREQUENTLY ASKED QUESTIONS


What is the difference between H01 and H02?


H01 models have 0.01mm resolution. H02 models have 0.001mm resolution and better listed accuracy.


What measuring ranges are available?


Both series offer 0–12.7mm and 0–25.4mm ranges.


Can they measure paper and plastic film?


Yes. Both applications are listed in the catalogue. Suitability depends on the required tolerance and material response to contact.


Does H02 have ±0.001mm accuracy?


No. H02-127 is listed at ±0.005mm and H02-254 at ±0.007mm.


Can it measure coating thickness separately?


No. It measures the total material thickness between the contacts.


Is measuring pressure specified?


The supplied page does not state measuring force or contact pressure. Confirm these requirements for compressible materials or standardised testing.


What information helps with selection?


Provide the material type, expected thickness, tolerance, distance from the sample edge and any required test method.


SEO META DESCRIPTION


Compare DITRON H01 and H02 digital thickness gauges in Malaysia. Explore paper and film measurement, 12.7mm and 25.4mm ranges, resolution and accuracy.


CONTACT MTM PRECISION


Contact MTM Precision with your material type, thickness range and inspection tolerance for assistance selecting a DITRON H01 or H02 Digital Thickness Gauge.


MTM Precision Sdn Bhd

Showroom & Service Centre: No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia

Tel: 03-8080 7172

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com

Website: www.mtmpre.com.my

25 Oct 2026