Professional Fuzrr ES3002E Multifunction Earth Resistance Tester (Malaysia)
Professional Fuzrr ES3002E Multifunction Earth Resistance Tester (Malaysia)
Product Applications
-
Earth ground resistance testing for power distribution networks, substations, transmission towers, and factory grounding grids
-
No-auxiliary pole online grounding resistance testing using selection or dual-clamp methods without disconnecting ground conductors
-
Soil resistivity (Wenner 4-pole method) surveys for electrical grounding grid design and site analysis
-
AC leakage current and load current testing up to 1000.0A in grounding loops and power lines
-
Voltage to ground (AC) and DC voltage measurements across lightning protection systems, computer rooms, and telecom sites
Key Features & Operational Advantages
-
Comprehensive Measurement Methods: Supports 4-wire precision, 3-wire, simple 2-wire, selection method, and dual-clamp method for ground resistance and DC resistance testing.
-
No-Auxiliary Ground Pole Testing: Utilizes dual-clamp technology to perform online ground resistance measurements without driving auxiliary ground stakes or disconnecting equipment ground bonds.
-
Extensive Soil Resistivity Range: Measures soil resistivity (ρ = 2πaR) from 0.00Ωm to 9999kΩm with selectable electrode spacing from 0.1m to 100.0m.
-
AC Current Measurement Capability: Integrates AC current testing from 0.00A up to 1000.0A with a fine resolution of 0.01mA.
-
High-Capacity Rechargeable Power: Built-in 11.1V lithium battery capable of delivering over 1000 continuous AC resistance measurements on a full charge.
-
Data Management & Rugged Enclosure: Features 500-group data storage, USB interface for PC data reading and export, controlled backlight, and IP45 ingress protection.
Technical Specifications — Fuzrr ES3002E
Core Measurement Parameters & Accuracy
-
2/3/4 Wire Method Grounding Resistance:
-
Range: 0.000Ω to 200.00kΩ
-
Precision: ±1.5% rdg ± 70dgt
-
Resolution: 0.001Ω
-
-
DC Resistance:
-
Range: 0.000Ω to 200.00kΩ
-
Precision: ±1.5% rdg ± 70dgt
-
Resolution: 0.001Ω
-
-
Selection Method Grounding Resistance:
-
Range: 0.00Ω to 3.000kΩ
-
Precision: ±2% rdg ± 30dgt
-
Resolution: 0.01Ω
-
-
Dual-Clamp Grounding Resistance:
-
Range: 0.00Ω to 200Ω
-
Precision: ±10% rdg ± 10dgt
-
Resolution: 0.01Ω
-
-
Soil Resistivity (ρ = 2πaR):
-
Range: 0.00Ωm to 9999kΩm
-
Precision: ρ = 2πaR
-
Resolution: 0.01Ωm
-
-
Voltage to Ground (AC Voltage):
-
Range: 0.000V to 50.00V
-
Precision: ±1.5% rdg ± 50dgt
-
Resolution: 0.001V
-
-
DC Voltage:
-
Range: 0.000V to 50.00V
-
Precision: ±1.5% rdg ± 50dgt
-
Resolution: 0.001V
-
-
AC Current:
-
Range: 0.00A to 1000.0A
-
Precision: ±2% rdg ± 50dgt
-
Resolution: 0.01mA
-
Measurement Speed & Conditions
-
Base Test Condition: 23°C ± 5°C, below 75% RH
-
Test Waveform & Frequency: Sine wave 128Hz
-
Electrode Spacing Setup Range: 0.1m to 100.0m
-
Measurement Time:
-
AC current: About 3 times / second
-
Ground resistance & soil resistivity: About 10 seconds / time
-
Functional Features & Data Management
-
Data Storage: 500 groups
-
USB Interface: USB interface for data reading, saving record data, and PC reporting
-
Backlight: Controlled backlight for dim environments
-
Automatic Shutdown: "APO" indicates automatic shutdown after 15 minutes of inactivity (default,shutdown time can be customized)
Hardware, Physical & Environmental Parameters
-
Power Supply: 11.1V Lithium battery (built-in, full charge allows > 1000 continuous tests in AC resistance mode)
-
Instrument Weight:
-
Main Instrument: 1975g (including battery)
-
Current Clamp: 940g (2 bars)
-
Test Line: 1300g
-
-
Ingress Protection Rating: IP45
-
Suitable Safety Regulations & Standards: IEC61010-1 (CAT III 300V, CAT IV 150V, Pollution degree 2); IEC61010-031; IEC61557-1 (earth resistance); IEC61557-5 (soil resistivity); JJG 366-2004 (earth resistance meter); JJG 1054-2009 (clamp earth resistance meter)
Why Choose MTM Precision in Malaysia?
10 Nov 2026