Split-Type Digital Anemometer in Malaysia: In-Depth Guide to the Swevy SW-6036 Anemometer
Split-Type Digital Anemometer in Malaysia: In-Depth Guide to the Swevy SW-6036 Anemometer
High-Resolution Wind Speed, Temperature & Humidity Diagnostics
-
Five Wind Speed Units with Fine Resolution: Measures airflow across 0.3–45 m/s (0.001 m/s resolution, 0.3 m/s minimum starting threshold), 59–8800 Ft/min (0.01/0.1/1 Ft/min resolution, 59 Ft/min minimum starting threshold), 0.58–88 Knots (0.01/0.1 Knots resolution, 0.58 Knots minimum starting threshold), 1.08–140 Km/h (0.001 Km/h resolution, 1.08 Km/h minimum starting threshold), and 0.67–100 mph (0.001/0.01 mph resolution, 0.67 mph minimum starting threshold)
. -
Defined Wind Speed Accuracy: Rated at ±(0.5 m/s + 0.05 x indicated wind speed) across low to high airflow velocities
. -
Ambient Temperature Measurement: Measures air temperature from 0.0°C to 45.0°C (32.0°F to 113.0°F) at 0.1°C / 0.1°F resolution
. -
Relative Humidity Measurement: Measures relative humidity from 1% RH to 99% RH at 1% RHresolution, giving HVAC and facility engineers immediate insight into indoor air comfort and dehumidification performance
.
Split-Probe Ergonomics, Rechargeable Power & Field Ratings in Malaysia
-
Separate Vane Probe with Coiled Cable: Allows the operator to reach ceiling diffusers, duct openings, fan guards, and louvers easily while reading wind speed, temperature, and humidity clearly on the handheld screen
. -
Compact Handheld Body & 3.7V Lithium Battery: Measures 64 x 157 x 30 mm and runs on a rechargeable 3.7V lithium battery, eliminating the hassle of frequent disposable battery replacements during busy commissioning schedules
. -
Operating & Storage Environment Ratings: Rated for -10°C to 50°C (14°F to 122°F) and 20% RH to 85% RH during operation, and -20°C to 60°C (-4°F to 140°F) and 10% RH to 90% RH during storage, aligning well with indoor mechanical rooms and field environments across Malaysia
.
Where the Swevy SW-6036 Adds Value Across Malaysia
-
Ceiling Diffusers, Grilles & Duct Balancing: Positioning the split vane probe directly at supply or return outlets to capture high-resolution airflow up to 45 m/s alongside temperature and 1%–99% RH humidity
. -
Cleanrooms, Server Rooms & Dehumidification Audits: Monitoring air velocity, temperature (0.0°C–45.0°C), and relative humidity simultaneously on a single screen
. -
Industrial Fans, Exhaust Hoods & Field Inspections: Reaching awkward vents safely with the tethered probe and a rechargeable 3.7V lithium-powered meter
.