Complete Guide to Elitech Inframate S Refrigerant Leak Detector Malaysia
The Elitech Inframate S is a professional infrared refrigerant leak detector intended for HVAC, refrigeration and compatible automotive air-conditioning applications.
It helps technicians search for supported refrigerant near accessible pipe joints, valves, coils, service ports and other suspected leak areas. However, it is important to understand what the detector measures, which refrigerants it supports and what its alarm does not confirm.
MTM Precision currently has one unit of Elitech Inframate S ready stock in Malaysia, subject to prior sale and final stock confirmation.
What Is the Elitech Inframate S?
The Inframate S is a handheld electronic refrigerant leak detector based on infrared absorption spectroscopy.
Compared with basic detectors using replaceable heated sensing elements, an infrared model may be considered by professional users who value:
Longer sensor-life potential
Resistance to high refrigerant concentrations
Reduced dependence on frequently replaced sensing elements
Fast response
Multiple sensitivity levels
Clear visual and audible indications
Suitability for regular HVAC and refrigeration work
A refrigerant detector is a locating instrument. It does not replace complete HVAC diagnosis, pressure measurement, pressure testing or professional assessment.
Published Inframate S Specifications
According to Elitech's published information, the Inframate S includes:
Infrared refrigerant sensing principle
Three sensitivity levels
Maximum published sensitivity below 4 g/year
Response time below one second
Approximately 30-second warm-up
Automatic calibration
Audible and visual alarm indication
Colour TFT display
Approximately eight hours of continuous operation
Automatic shutdown after inactivity
Flexible probe approximately 445 mm long
Published sensor life of approximately 10 years
These figures apply under the manufacturer's stated conditions.
Actual detection can be affected by refrigerant compatibility, leak size, airflow, background refrigerant, probe movement, filter condition and the working environment.
Supported Refrigerant Groups
Elitech publishes support for refrigerants within the following groups:
CFC
HCFC
HFC
HFO-1234yf
The exact refrigerant should be identified before purchasing or using the detector.
Relevant information may be found on:
Equipment nameplate
Compressor label
Outdoor-unit label
Vehicle refrigerant label
System documentation
Maintenance records
Previous service reports
A description such as "Freon leak detector" does not mean that the instrument supports every refrigerant or gas.
Understanding the Three Sensitivity Levels
Elitech publishes the following sensitivity levels:
High: 0.1 oz/year, below 4 g/year
Medium: 0.25 oz/year, approximately 7 g/year
Low: 0.50 oz/year, approximately 14 g/year
Higher sensitivity may help when searching for a smaller refrigerant concentration. It may also make the detector more responsive to refrigerant already present in the surrounding air.
A published sensitivity figure does not guarantee that every leak of that rate will be located under all site conditions.
The result can be influenced by:
Air movement
Background refrigerant
Probe distance
Probe speed
Leak accessibility
Filter condition
Instrument preparation
Operating environment
What Does the Detector Alarm Mean?
An alarm means that compatible refrigerant may be present near the probe.
It does not independently confirm:
Exact physical leak point
Leak-opening size
Total refrigerant loss
Remaining refrigerant charge
System pressure
Cooling capacity
Compressor condition
Required repair
Complete system safety
The suspected area should be narrowed down and verified using an appropriate method before repair work begins.
Common Refrigerant Leak Areas
Depending on the equipment design, possible leak areas may include:
Flare joints
Brazed connections
Service valves
Schrader valves
Charging ports
Compressor connections
Evaporator coils
Condenser coils
Filter-drier connections
Pressure sensor connections
Refrigerant pipe fittings
Corroded tubing
Components affected by vibration
Previously repaired sections
A detector response near a component does not automatically prove that the component has failed.
Residential Air-Conditioning Applications
Residential air-conditioning technicians may use a compatible leak detector while investigating:
Weak cooling
Repeated refrigerant charging
Oil residue near a connection
Suspected leakage around a flare joint
Previous refrigerant-circuit repair
Damaged or vibrating pipework
Poor cooling does not automatically confirm refrigerant leakage.
Other possible causes include:
Dirty air filter
Restricted airflow
Dirty evaporator
Dirty condenser
Fan problem
Electrical fault
Temperature sensor issue
Compressor problem
Refrigerant circuit restriction
The Inframate S is one tool within the complete troubleshooting process.
Commercial HVAC Applications
Commercial HVAC contractors and facility teams may inspect compatible equipment serving:
Offices
Shopping premises
Hotels
Restaurants
Factories
Warehouses
Educational facilities
Healthcare facilities
Apartment common areas
Technical facilities
Commercial systems may contain multiple connections, coils and service points.
Strong ventilation, air-handling equipment and condenser fans can carry refrigerant away from the leak source. The location of the first detector response may not be the original source.
Cold Room and Refrigeration Applications
Cold rooms and commercial refrigeration systems may be used for:
Frozen food
Meat and seafood
Dairy products
Fresh produce
Restaurant supplies
Food-processing materials
Supermarket products
Temperature-sensitive inventory
A leak detector may support inspection around accessible valves, joints, compressor fittings and coil sections.
However, a cold room that cannot maintain temperature may also have:
Dirty condenser
Restricted evaporator airflow
Fan failure
Damaged door seal
Insulation problem
Control fault
Compressor problem
Excessive door opening
Refrigerant leak checking should form part of a broader refrigeration assessment.
Automotive Air-Conditioning Applications
Elitech includes HFO-1234yf in its published detectable refrigerant information for the standard Inframate S.
Automotive workshops should confirm:
Vehicle refrigerant label
Exact refrigerant
Detector compatibility
Required sensitivity
Applicable servicing requirements
Possible automotive leak areas may include:
Service ports
Valve cores
Hose connections
Compressor connections
Condenser
Evaporator
Pressure sensor connections
Damaged pipework
The Inframate S is not a refrigerant identifier. It cannot confirm the composition or purity of an unknown refrigerant.
Infrared vs Heated Diode Detectors
Infrared Detector
An infrared detector may be preferred when:
The instrument will be used regularly
Longer sensor life is important
High refrigerant exposure is possible
Reduced sensing-element replacement is preferred
Long-term operating cost matters
A professional-level detector is required
Heated Diode Detector
A heated diode detector may remain practical when:
Usage is occasional
Initial purchasing budget is limited
Replacement sensing elements are acceptable
A basic detector meets the requirement
The selected model supports the refrigerant
An infrared detector is not automatically the correct choice for every user. The application, refrigerant, workload and budget should be considered together.
Sensor Life and Long-Term Ownership
Elitech publishes a sensor life of approximately 10 years for the Inframate S.
This does not mean:
The complete detector requires no maintenance
The battery will last for 10 years
The filter never requires attention
The probe cannot be damaged
Functional checking is unnecessary
Every instrument will operate for exactly 10 years
Long-term cost may include:
Filter replacement
Battery care
Probe damage
Accessories
Instrument downtime
Technical assessment
Repair or replacement
The longer-life sensor may still provide value for technicians who perform frequent leak inspections.
Resistance to High Refrigerant Concentrations
Elitech states that the Inframate S infrared sensor is designed not to be damaged under high refrigerant concentration conditions.
This does not mean that the detector should be deliberately exposed to concentrated refrigerant.
Technicians must still follow:
Proper refrigerant-handling procedures
Ventilation requirements
Instrument maintenance
Filter care
Applicable safety requirements
Environmental responsibilities
Deliberate refrigerant release should not be used as an improvised detector test.
Warm-Up and Automatic Calibration
Elitech publishes an approximately 30-second warm-up time and identifies automatic calibration among the Inframate S functions.
The detector should be allowed to complete normal preparation before inspection begins.
Preparing the instrument in air that already contains refrigerant may affect the reference condition and make localisation more difficult.
Technicians should follow the current Elitech manual rather than using an unverified preparation or testing procedure.
Flexible Probe and Access
Elitech publishes a probe length of approximately 445 mm.
The flexible probe may assist when checking around accessible:
Coil connections
Compressor pipework
Service valves
Refrigerant joints
Components positioned behind other equipment parts
The probe must not be placed near:
Moving fans
Belts
Pulleys
Live electrical parts
Hot exhaust components
Rotating machinery
A detector does not remove the need for proper electrical and mechanical safety procedures.
Airflow and False Alarm Considerations
Airflow may come from:
Indoor-unit fan
Condenser fan
Mechanical ventilation
Exhaust fan
Workshop fan
Open door or window
Outdoor wind
Air movement can carry refrigerant away from its original source.
Recent charging, recovery or hose disconnection may also leave refrigerant in the surrounding air. This can cause the detector to respond broadly or at a location away from the active leak.
A wide-area alarm does not confirm that every nearby connection is leaking.
Why the Detector May Not Respond
No response near a suspected area may be related to:
Unsupported refrigerant
Probe positioned too far away
Probe movement that is too fast
Strong airflow
Leak located in a concealed section
Leak behaving intermittently
Detector not fully prepared
Filter condition
Battery condition
No active leak at that location
A non-response does not prove that the complete system is leak-free.
Why the Detector May Keep Alarming
Continuous or widespread alarming may be associated with:
Background refrigerant
Recent servicing
Larger nearby leak
Poor ventilation
Refrigerant trapped inside a cabinet
Airflow distributing refrigerant
High sensitivity
Probe or filter contamination
Instrument condition requiring assessment
The environment and instrument condition should be reviewed before the detector is considered defective.
Inframate S vs Inframate S MAX
The Inframate S and Inframate S MAX are separate models.
Elitech publishes:
Inframate S
Maximum sensitivity below 4 g/year
Three published sensitivity levels
Support for CFC, HCFC, HFC and HFO-1234yf groups
Probe approximately 445 mm long
Published sensor life of approximately 10 years
Inframate S MAX
Maximum sensitivity of 1 g/year
Specifically identified as A2L compatible
Intended for halogen refrigerants according to Elitech
Probe approximately 340 mm long
Published sensor life of at least 10 years
Customers requiring specifically documented A2L compatibility or higher sensitivity should evaluate the S MAX.
Specifications belonging to the S MAX must not be applied automatically to the standard Inframate S.
Selecting the Correct Model
Before purchasing, confirm:
Exact refrigerant
HVAC, refrigeration or automotive application
Required sensitivity
Frequency of use
A2L compatibility requirement
Infrared or heated diode preference
Working environment
Probe accessibility
Sensor and filter maintenance expectations
Required quantity
Delivery location
Current stock
The detector should be chosen according to the application rather than price or sensitivity alone.
Maintenance and Storage
The detector should be protected from:
Oil
Water
Condensation
Heavy dust
Chemical vapour
Physical impact
Probe crushing
Excessive heat
Unsuitable cold storage
Moving machinery
Any cleaning, filter replacement, battery work or functional checking should follow the current Elitech instructions.
Do not use:
Unverified cleaning chemicals
Sharp tools inside the probe
Improvised test gases
Deliberate refrigerant release
Unauthorised internal adjustments
Procedures intended for another detector model
Checking, Calibration and Repair
These terms should not be treated as interchangeable.
Checking
Checking confirms whether the instrument appears to start, prepare and respond according to the manufacturer's approved method.
Calibration
Calibration compares instrument performance with an appropriate reference under controlled conditions and documents the result according to the applicable process.
A basic response check should not automatically be described as calibration.
Repair
Repair addresses a confirmed battery, probe, display, housing or internal instrument problem.
The appropriate action depends on the observed symptom and technical assessment.
When Further Instrument Assessment May Be Required
Further checking may be appropriate when the detector:
Does not power on
Cannot hold battery charge
Does not complete normal preparation
Responds continuously in a suitable clean environment
Does not respond during the approved functional check
Has a damaged probe
Has a visibly contaminated filter
Shows signs of moisture entry
Has suffered a strong impact
Produces repeated unstable indications
Do not dismantle or adjust the detector based on an unverified online procedure.
Regional Supply for Johor
Johor HVAC contractors, cold-room technicians and automotive workshops may contact MTM Precision for:
Product selection
Stock confirmation
Formal quotation
Model clarification
Delivery arrangement
Provide the exact refrigerant, application and delivery location when requesting a quotation.
Regional Supply for Penang
Penang factories, facility teams, HVAC contractors and refrigeration technicians may contact MTM Precision remotely.
The customer does not need to visit the Puchong showroom to request:
Product information
Compatibility clarification
Stock confirmation
Quotation
Delivery arrangement
Industrial ventilation, outdoor airflow and site contamination should be considered when selecting and using a detector.
Selangor and Kuala Lumpur Enquiries
Customers in Selangor and Kuala Lumpur may confirm availability before visiting the Puchong showroom.
MTM Precision's Showroom and Service Centre is located at:
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
Because current stock is limited, availability should be reconfirmed before visiting or arranging collection.
Elitech Inframate S Ready Stock Malaysia
MTM Precision currently has one unit of Elitech Inframate S ready stock, subject to prior sale and final confirmation.
Customers should provide:
Full model name
Exact refrigerant
Intended application
Required quantity
Delivery or collection location
MTM Precision does not publish the selling price in this article. Contact us for a current quotation.
Frequently Asked Questions
1. What is the Elitech Inframate S?
It is a handheld infrared refrigerant leak detector for professional HVAC, refrigeration and compatible automotive air-conditioning applications.
2. Which refrigerant groups does it support?
Elitech publishes support for CFC, HCFC, HFC and HFO-1234yf refrigerant groups.
3. What is its highest published sensitivity?
Elitech publishes a high sensitivity level of 0.1 oz/year, below 4 g/year.
4. Does it have different sensitivity levels?
Yes. Elitech publishes high, medium and low sensitivity levels.
5. What is the published response time?
Elitech publishes a response time below one second under the stated conditions.
6. How long is the warm-up time?
The published warm-up time is approximately 30 seconds.
7. How long is the published sensor life?
Elitech publishes a sensor life of approximately 10 years under the stated conditions.
8. Can it be used for cold-room maintenance?
It may be considered when the cold-room system uses a supported refrigerant.
9. Can it be used for HFO-1234yf automotive air-conditioning?
Elitech includes HFO-1234yf in the standard Inframate S detectable refrigerant information. The exact vehicle refrigerant must still be confirmed.
10. Can it identify an unknown refrigerant?
No. A leak detector is not a refrigerant identifier.
11. Can it measure pressure or refrigerant charge?
No. Suitable pressure-measurement and servicing instruments are required.
12. Why might it alarm throughout the work area?
Background refrigerant, recent servicing, airflow, high sensitivity or instrument contamination may cause a broad response.
13. Is the standard Inframate S identified as A2L compatible?
Elitech specifically identifies the Inframate S MAX as A2L compatible. Verify the exact model for A2L applications.
14. Is the Elitech Inframate S available in Malaysia?
MTM Precision currently has one unit available, subject to prior sale and final stock confirmation.
15. How can I request a quotation?
Provide MTM Precision with the exact refrigerant, equipment application, required quantity and delivery or collection location.
Internal Linking
Elitech Inframate S Infrared Refrigerant Leak Detector Supplier Malaysia
Infrared vs Heated Diode Refrigerant Leak Detector Malaysia
How to Choose a Refrigerant Leak Detector for HVAC Work Malaysia
Refrigerant Leak Detection for Cold Room Maintenance Malaysia
Air Conditioner Not Cooling and Refrigerant Leak Cannot Be Found Malaysia
Elitech Inframate S vs Inframate S MAX Refrigerant Leak Detector Malaysia
HFO-1234yf Automotive Air Conditioning Leak Detection Malaysia
Commercial HVAC Refrigerant Leak Inspection and Preventive Maintenance Malaysia
Refrigerant Leak Detector Keeps Alarming or Does Not Respond Malaysia
How to Maintain an Infrared Refrigerant Leak Detector Malaysia
Elitech Inframate S Refrigerant Leak Detector for Johor HVAC Contractors Malaysia
Elitech Inframate S Refrigerant Leak Detector for Penang Industry Malaysia
Where to Buy Elitech Inframate S Refrigerant Leak Detector Malaysia
Elitech Inframate S FAQ, Applications and Limitations Malaysia
SEO Meta Title
Complete Guide to Elitech Inframate S Malaysia
SEO Meta Description
Complete guide to the Elitech Inframate S infrared refrigerant leak detector covering sensitivity, supported refrigerants, HVAC, cold-room and automotive applications, troubleshooting, maintenance and Malaysia availability.
For product selection, stock confirmation or quotation, WhatsApp MTM Precision with the exact refrigerant, equipment application and delivery location.
MTM Precision Sdn Bhd
Showroom & Service Centre:
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
Tel: +603-80807172
WhatsApp / Mobile: +6016-6607346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
24 Nov 2026