Share:


CUSTOM Digital Multimeter CDM-7000

Specifications

SKU: CUSTOM Digital Multimeter CDM-7000

Product overview

[Measurement item] AC voltage
[Measurement item] AC voltage (millivolts)
[Measurement item] DC voltage
[Measurement item] DC voltage (millivolts)
[Measurement item] AC current
[Measurement item] AC current (milliamperes)
[Measurement item] AC current (microamperes)
[Measurement item] DC current
[Measurement item] DC current (milliamperes)
[Measurement item] DC current (microamperes)
[Measurement item] Resistance
[Measurement item] Diode check
[Measurement item] Capacitor check
[Measurement item] Frequency
[Measurement item] Duty check
[Measurement item] Low voltage voltage detectionCovered AC Wire
[Measurement items] Temperature, K thermocoupleSensor included
[Function] Hold
[Function] Deviation
[Features] Equipped with backlight
[Features] TRUE RMS
[Function] Stand
*1 LED & buzzer notification
*2 Approximately 30 minutes (cancellable)

A standard model that combines functions frequently used at work sites

  • Voltage (DC, AC), current (DC, AC), resistance, frequency, capacitance, temperature, continuity check function, diode check function.
  • The true RMS method allows the display of RMS values ​​for waveforms other than sine waves.
  • Other features include duty check function, data hold function, and relative comparison function.
  • It has a backlight, making it easy to check the values ​​even when working in a dark place.
  • Equipped with an auto power off function to prevent battery drain.
  • Equipped with non-contact voltage detection function (NCV).
  • Test leads can be attached and stored on the back.
  • Comes with a shock-absorbing holster case.

With non-contact voltage detection function (NCV)

CDM-7000 Non-contact voltage detection※imageWhen the detector on the top of the unit is brought close and AC voltage is detected, a buzzer and LED will sound to notify you.
*The detection voltage range is AC 90-1000V, 50-60Hz. This function is a guideline, so to measure the exact voltage, please use the AC voltage (ACV) measurement function of this device.

The test leads can be stored on the back of the main unit.

CDM-7000 test lead storage

Product Details

Part names

CDM-7000 Part names
  • ① Liquid crystal display section
  • ② Select button
  • ③ Range button
  • ④ Function Dial
  • ⑤ 10A input terminal
  • ⑥ COM input terminal
  • ⑦ V/Ω/Diode/Continuity/Capacitor/Hz/%/Temperature/μA/mA Input Terminal
  • ⑧ Frequency/Duty/Relative button
  • ⑨ Backlight/Hold Button
  • ⑩ Voltage detector (NCV)
  • ⑪ Test lead attachment part
  • ⑫ Stand
  • ⑬ Battery cover
  • ⑭ Probe cover
  • ⑮ Barrier part of test lead
  • ⑯ Test lead
▲Back to top of page

specification

Electrical Performance

  range resolution Accuracy remarks
DCV 600 mV / 6 V / 60 V / 600 V 0.1 mV /0.001 V / 0.01 V / 0.1 V ±(0.5% + 2 dgt)
  • Input impedance 10 MΩ
1000 V 1 V ±(0.8% + 3 dgt)
ACV 600 mV / 6 V / 60 V 0.1 mV /0.001 V / 0.01 V ±(0.8% + 2 dgt)
  • Input impedance 10 MΩ
  • 40 Hz to 1000 Hz
600V / 750V 0.1V / 1V ±(1.0% + 3 dgt)
DCA 600 μA / 6000 μA / 60 mA / 600 mA 0.1 μA / 1 μA / 0.01 mA / 0.1 mA / ±(1.0%rdg + 2dgt)
  • Up to 10 A
10A 0.01 A ±(1.5%rdg + 3dgt)
ACA 600 μA / 6000 μA / 60 mA / 600 mA 0.1 μA / 1 μA / 0.01 mA / 0.1 mA ±(1.0% + 3 dgt)
  • Up to 10 A
  • 50 Hz to 60 Hz
10A 0.01 A ±(1.5% + 3 dgt)
Ω 600Ω / 6kΩ / 60kΩ / 600kΩ 0.1 Ω / 0.001 kΩ / 0.01 kΩ / 0.1 kΩ ±(0.8%rdg + 2dgt)
  • Open circuit voltage: approx. 0.3 V
6 MΩ / 60 MΩ 0.001 MΩ / 0.01 MΩ ±(2.0%rdg + 3dgt)
capacitance 60nF / 600nF / 6μF / 60μF 0.01 nF / 0.1 nF / 0.001 μF / 0.01 μF ±(3.0%rdg + 3dgt)
  • 10 nF to 60 mF
600 μF / 6 mF / 60 mF 0.1 μF / 0.001 mF / 0.01 mF ±(5.0%rdg + 5dgt)
temperature 1000℃ 1°C ±(2.5%rdg + 3dgt)
  • -20℃ to 400℃
  • K-type thermocouple
 
  Buzzer Threshold remarks
Continuity check Approximately 50 MΩ
  • Open circuit voltage: approx. 1.0 V
  range resolution remarks
Diode Check 0 V to 3 V 1 mV
  • Open circuit voltage: approx. 3.3 V
  Measurement range Accuracy frequency
frequency 1 Hz to 5 MHz ±(0.8%rdg + 2dgt) 1.0 Vrms or more, sine wave, 50% square wave
DUTY 1.0 to 99.0% ±(2.5% + 3 dgt) 10 Hz to 10 kHz, 1.5Vrms or more, square wave
Voltage tester AC 90 V to AC 1000 V - 50 Hz or 60 Hz
*Accuracy guarantee for AC voltage/current is limited to sine waves.
*At 23±5°C, 75% RH or less

General specifications

Detection method True RMS
display LCD, maximum display “6000”
Range switching Auto/Manual
polarity display Automatic switching, only "-" displayed
sampling Approximately 3 times/second
Auto Power Off Approximately 30 minutes (can be canceled)
Operating temperature and humidity 0 to +40°C, 80% RH or less (no condensation)
Storage temperature and humidity -10 to +60°C, 80% RH or less (no condensation)
size Approx. W 74 × H 148 × D 38 mm
weight Approximately 210 g (including batteries)
Test lead length Approximately 75cm
power supply 2 x AA batteries
battery life Approximately 900 hours (when using alkaline batteries)
accessories Instruction manual, test leads, K-type thermocouple, battery cover screwdriver
option
proofreading Possible
Compliance standards IEC61010-1 CAT III 600V
JAN 4983621100433
*The battery included with this device is a sample. It may have a shorter battery life than regular commercially available batteries. Heavy use of the backlight/buzzer will shorten the battery life.


 Inquiry - CUSTOM Digital Multimeter CDM-7000