CUSTOM Clamp Meter AC Leak Clamp Meter C-14 AC Leak Clamp Meter C-14
Brand: CUSTOM
Specifications
SKU: CUSTOM Clamp Meter AC Leak Clamp Meter C-14 AC Leak Clamp Meter C-14
Product overview
A clamp meter with a low-pass filter that can measure everything from load current to leakage current
- True RMS measurement type that can accurately measure even distorted waveforms
- The clamp shape is perfectly round and the maximum measurement conductor diameter is Φ32mm
- LPF/PEAK measurement/HOLD function
- Supports operation in dark places (dial, indicator, LCD, and operation buttons light up).
- The flashlight illuminates dark places.
Features
Current measurement image
flash light image
Backlight imagePart names
Main unit
- ①Clamp sensor
- ②Clamp opening/closing lever
- ③Backlight button *
- ④Range indicator *
- ⑤LPF button *
- ⑥PEAK measurement button *
- ⑦Dial indicator *
- ⑧Range dial
- ⑨Display section
- ⑩HOLD, flashlight button
- ⑪ Barrier part of clamp
- ⑫LED light section
360° rotating image
Clicking on the image will open a new window.
specification
Electrical Performance
| range | resolution | Frequency Range | Accuracy (LPF: OFF) | Accuracy (LPF: ON) | Accuracy guarantee range |
|---|---|---|---|---|---|
| 6.000mA | 0.001mA | 50/60 Hz | ±(1.0% + 8 dgt) | ±(1.5% + 8 dgt) | 0.300 - 6.000 mA |
| 60 Hz - 1 kHz | ±(3.0%rdg + 8dgt) | - | |||
| 60.00 mA | 0.01mA | 50/60 Hz | ±(1.0% + 5 dgt) | ±(1.5% + 8 dgt) | 3.000 - 60.00 mA |
| 60 Hz - 1 kHz | ±(3.0%rdg + 8dgt) | - | |||
| 600.0 mA | 0.1mA | 50/60 Hz | ±(1.0% + 5 dgt) | ±(1.5% + 8 dgt) | 30.00 - 600.0 mA |
| 60 Hz - 1 kHz | ±(3.0%rdg + 8dgt) | - | |||
| 6,000 A | 0.001 A | 50/60 Hz | ±(1.0% + 8 dgt) | ±(1.5% + 8 dgt) | 0.300 - 6.000 A |
| 60 Hz - 1 kHz | ±(3.0%rdg + 8dgt) | - | |||
| 60.00 A | 0.01 A | 50/60 Hz | ±(1.5% + 8 dgt) | ±(1.5% + 8 dgt) | 3.000 - 60.00 A |
| 60 Hz - 1 kHz | ±(3.0%rdg + 8dgt) | - | 3.000 - 10.00 A | ||
| 60 Hz - 400 Hz | 10.00 - 60.00 A | ||||
| 100.0 A | 0.1 A | 50/60 Hz | ±(1.5% + 8 dgt) | ±(2.0% + 8 dgt) | 6.000 - 100.0 A |
| 60 Hz - 1 kHz | ±(3.5%rdg + 8dgt) | - | 6.000 - 10.00 A | ||
| 60 Hz - 400 Hz | 10.00 - 60.00 A |
* The measurement frequency range varies depending on the measurement current value, even within the same range.
* The maximum rated current is AC100A, and the maximum rated voltage is AC300V.LPF (Low Pass Filter) Cutoff Frequency: 190±20 Hz (-3dB)
General specifications
| Detection method | True RMS method |
|---|---|
| display | 6000 counts |
| Maximum measurement conductor diameter | φ32 mm |
| polarity display | Automatic switching "-" sign only |
| sampling | Approximately 5 times/second |
| Auto Power Off | Approximately 15 minutes (can be canceled) |
| Operating temperature and humidity | +5 to +40°C, 80% RH or less (no condensation) |
| Storage temperature and humidity | -20 to +60°C, 80% RH or less (no condensation) |
| size | Approximately W 85 × H 233 × D 45 mm |
| weight | Approximately 360 g (including batteries) |
| power supply | 3 x AAA batteries (batteries sold separately) |
| battery life | Approximately 23 hours of continuous use |
| accessories | Instruction manual (with warranty), soft case |
| proofreading | Possible |
| Compliance standards | EN61010-1/IEC6101010-2-032 CAT.III AC300V |
| JAN | 4983621090277 |
Inquiry - CUSTOM Clamp Meter AC Leak Clamp Meter C-14 AC Leak Clamp Meter C-14