How to Choose the Right Anchor Pull-Out Tester for Construction Projects Malaysia
How to Choose the Right Anchor Pull-Out Tester for Construction Projects Malaysia
Anchor Pull-Out Tester Selection Guide Malaysia
Choosing the correct anchor pull-out tester requires more than checking whether a machine is rated at 10 ton, 20 ton or 30 ton.
The most suitable tester should match the actual test requirement, including the anchor type, expected tensile load, adapter connection, site access, reaction setup and project testing method.
For construction contractors, QA/QC teams, engineering consultants, inspection companies and testing laboratories in Malaysia, selecting the right equipment can help avoid two common problems:
Buying a tester with insufficient capacity
Buying a much larger system than the application actually requires
The Langry APT100, APT200 and APT300 provide different load ranges for different anchor testing requirements.
Step 1 – Know What Type of Anchor You Are Testing
The first question should be:
What exactly are you testing?
Common applications may include:
Chemical anchors
Mechanical anchors
Expansion bolts
Anchor rods
Threaded rods
Steel bars
Post-installed rebar
Curtain wall anchors
Façade anchors
Structural fixings
Different anchoring systems may require different adapters and testing arrangements.
Step 2 – Determine the Required Test Load
This is one of the most important selection criteria.
Do not select a tester simply because a supplier says it is “20 ton.”
You should first know the required test load from:
Project specification
Engineer’s requirement
Anchor system specification
Approved test method
QA/QC procedure
The tester must have sufficient capacity for the required load.
Step 3 – Do Not Confuse Tester Capacity with Test Load
If a tester has a 200kN maximum range, it does not mean every anchor should be tested to 200kN.
For example:
Langry APT200 = 0–200kN maximum measurement range
The actual test may require a much lower load.
The tester provides the available capacity.
The project determines how much force should be applied.
Step 4 – Choose the Correct Capacity
Langry offers several common capacities.
ModelMaximum RangeApproximate CapacityAPT1000–100kN10 TonAPT2000–200kN20 TonAPT3000–300kN30 Ton
A simple selection approach is:
Below 100kN: consider APT100
Above 100kN and up to 200kN: consider APT200
Above 200kN and up to 300kN: consider APT300
The final selection should still consider the complete test setup.
Step 5 – Check the Anchor Diameter
Anchor diameter is important, but it should not be used as the only selection factor.
The Langry APT200 configuration lists common anchorage applications within approximately Φ6–Φ25.
However, the user should also confirm:
Required force
Thread size
Pulling connection
Exposed length
Adapter availability
Test geometry
A tester can have enough capacity but still require the correct mechanical connection.
Step 6 – Check the Thread or Connection Type
The tester must connect securely to the anchor.
Possible connections may involve:
Threaded adapters
Pull rods
Converters
Special fixtures
Couplers
For the Langry APT200, the listed configuration includes:
M24 pull rod
M6–M22 converters
The actual connection should be confirmed before the test.
Step 7 – Check the Available Exposed Anchor Length
Sometimes an anchor is suitable for testing in terms of load, but there is not enough exposed thread or rod to attach the pulling system.
This is a common site issue.
Before testing, check:
Exposed thread length
Available bar length
Accessibility
Nearby obstructions
Clearance for the hydraulic cylinder
Planning the test setup in advance can prevent problems later.
Step 8 – Consider the Reaction Setup
The hydraulic tester needs a stable reaction arrangement.
The reaction setup should match the anchor location and substrate.
Factors to consider include:
Concrete surface condition
Nearby edges
Nearby anchors
Anchor spacing
Local substrate strength
Available support area
Test fixture geometry
Poor reaction setup can affect both safety and test reliability.
Step 9 – Consider Site Access
A tester that is easy to use on the ground may be more difficult to use in confined or elevated areas.
Examples include:
Curtain wall installations
Ceiling supports
Plant rooms
Narrow service areas
High-rise façade work
Tight structural spaces
Portability and physical size should therefore be considered.
Step 10 – Check Cylinder Stroke
Hydraulic cylinder stroke can affect the available movement during testing.
The Langry APT200 provides a 70mm cylinder stroke.
This can be useful where some movement is expected during the loading process.
However, the actual test setup should still be checked carefully.
Step 11 – Check the Cylinder Centre Hole
The cylinder centre hole affects the type of pulling arrangement that can pass through the hydraulic cylinder.
The Langry APT200 has a 35mm centre hole.
This should be considered when selecting the pull rod and adapter configuration.
Step 12 – Consider Data Recording
For professional QA/QC and inspection work, recording the result may be important.
The Langry APT series supports storage of up to 500 measurement records.
This can be useful when multiple anchors are tested across a project.
Typical records may include:
Test location
Anchor number
Required load
Maximum applied load
Test result
Date
Operator details
Step 13 – Consider Accuracy Requirements
The Langry APT200 is specified with an EN ISO 7500-1 Class 1 accuracy classification.
For professional testing applications, measurement accuracy should always be considered.
Where a project has specific calibration or traceability requirements, these should also be checked before testing begins.
Step 14 – Check Operating Time
Field testing may involve long work periods.
The Langry APT series provides more than 200 hours of continuous working time according to the listed specification.
This can be useful for site work where multiple anchors need to be tested.
Step 15 – Consider Equipment Weight
Higher-capacity hydraulic equipment can be heavier.
The Langry APT200 cylinder weighs approximately 13kg.
For ground-level testing this may not be a major issue, but weight becomes more important when testing:
At height
On scaffolding
Inside confined areas
Across multiple floors
At many test points
The user should therefore balance required capacity with site portability.
What Capacity Is Best for Chemical Anchors?
There is no single answer.
The correct tester depends on:
Rod diameter
Anchor system
Embedment depth
Base material
Required proof load
Project specification
For lighter requirements, APT100 may be sufficient.
For broader construction use, APT200 may offer more flexibility.
For higher-load applications, APT300 may be required.
What Capacity Is Best for Expansion Bolts?
The same principle applies.
Do not select based only on bolt diameter.
Check:
Required tensile load
Anchor type
Installation condition
Base material
Test procedure
A 20-ton tester may be useful for users handling multiple mechanical anchor sizes, but only when the required load falls within its working range.
What Capacity Is Best for Rebar Pull-Out Testing?
Rebar and steel bar testing can involve relatively high tensile loads.
Before selecting equipment, check:
Bar diameter
Expected load
Steel grade
Anchorage system
Embedment
Project requirement
If the required load may exceed 100kN, a 100kN tester may not provide enough capacity.
In this case, APT200 or APT300 may be more suitable.
What Capacity Is Best for Curtain Wall Contractors?
Curtain wall and façade contractors may encounter different anchor types across different projects.
A broader-capacity tester may provide more flexibility.
However, the decision should still be based on actual project requirements.
For many mixed construction applications, the APT200 200kN / 20-ton class can offer a practical middle range.
What Capacity Is Best for Testing Companies?
Testing laboratories and inspection companies often work for different clients.
Their future test requirements may be less predictable.
When selecting a tester, they should review:
Typical historical test loads
Maximum expected project load
Types of anchors normally tested
Future service scope
Portability requirements
A wider-capacity system may provide greater flexibility where the company expects varied testing work.
Should You Buy the Largest Model?
Not necessarily.
Buying the largest tester can provide more capacity, but it may also mean:
More weight
Less portability
Higher cost
Larger equipment
More difficult handling
If your normal testing never exceeds 150kN, a 300kN tester may not provide much practical advantage over a suitable 200kN system.
The best choice is the one that matches your work.
Why the Langry APT200 Is a Practical Middle Choice
The APT200 is often attractive because it sits between the 100kN and 300kN models.
Key specifications include:
SpecificationLangry APT200Measurement Range0–200kNApproximate Capacity20 TonCylinder Centre Hole35mmCylinder Stroke70mmCylinder WeightApprox. 13kgCommon AnchorageΦ6–Φ25Pull RodM24ConverterM6–M22Data Storage500 RecordsContinuous Working Time>200 HoursAccuracy ClassificationEN ISO 7500-1 Class 1
For users who want more capacity than a 100kN system without moving directly to 300kN, the APT200 can be a practical choice.
Common Mistakes When Buying an Anchor Pull-Out Tester
Mistake 1 – Buying Only by Ton Rating
“20 ton” does not tell you whether the adapters and test geometry are suitable.
Mistake 2 – Ignoring the Required Test Load
Never buy a tester before confirming the maximum expected load.
Mistake 3 – Ignoring the Anchor Connection
A strong tester is useless if it cannot connect safely to the anchor.
Mistake 4 – Ignoring Site Accessibility
Heavy equipment can be difficult to use at height or inside restricted areas.
Mistake 5 – Assuming One Setup Fits Every Anchor
Different anchors may need different adapters and fixtures.
Mistake 6 – Buying Too Small
A tester operating too close to its maximum range on a regular basis may limit future work.
Mistake 7 – Buying Too Large
Extra capacity is unnecessary if the user never needs it.
Questions to Provide to Your Supplier
Before requesting a quotation, provide:
Anchor type
Anchor diameter
Thread size
Required proof load
Maximum expected load
Base material
Installation method
Exposed anchor length
Site location
Testing application
This helps the supplier recommend a more suitable configuration.
Frequently Asked Questions
How do I choose an anchor pull-out tester?
Start with the required test load, then confirm anchor type, connection, test setup, site access and project requirements.
Is a 20-ton tester enough?
It depends on the maximum required test load. A 200kN / 20-ton class tester is sufficient only if the test requirement remains within its range.
Is a larger-capacity tester more accurate?
Not necessarily. Capacity and accuracy are separate equipment characteristics.
Can one tester be used for both chemical and mechanical anchors?
Yes, provided the load range, adapters and test arrangement are suitable.
Is the Langry APT200 portable?
It is designed as a field pull-out testing system, although the cylinder weighs approximately 13kg, so site handling should be considered.
Can the APT200 store results?
Yes. The system supports up to 500 measurement records.
Which model should I buy if I am unsure?
Obtain the required test load and anchor details first. MTM Precision can then help compare the Langry APT100, APT200 and APT300.
Where can I buy an anchor pull-out tester in Malaysia?
MTM Precision Sdn. Bhd. supplies Langry anchor pull-out testers and other construction testing instruments in Malaysia.
Anchor Pull-Out Tester Supplier Malaysia
MTM Precision supplies professional construction, civil engineering and inspection equipment for customers in Malaysia.
If you are choosing between a 100kN, 200kN or 300kN anchor pull-out tester, send us your application details and required test load.
This allows us to recommend a more suitable model instead of simply offering the largest machine.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
For Langry APT100, APT200 and APT300 Anchor Pull-Out Tester Malaysia, model selection, quotations and construction testing equipment enquiries, contact MTM Precision.
11 Aug 2026