200kN 20 Ton Anchor Pull-Out Tester Malaysia Langry APT200

200kN 20 Ton Anchor Pull-Out Tester Malaysia Langry APT200 Looking for a 200kN Anchor Pull-Out Tester in Malaysia? If your construction, civil engineering or inspection project requires an anchor pull-out tester with up to 200kN capacity, the Langry APT200 is a professional hydraulic testing solution designed for on-site anchorage testing. The Langry APT200 provides a measurement range of: 0200kN This corresponds to approximately: 20-ton class testing capacity The tester can be used for suitable pull-out testing applications involving anchor rods, steel bars, expansion bolts and other anchoring components. For contractors, QA/QC teams, consultants and testing companies in Malaysia, the APT200 provides a practical middle-capacity option between Langry's 100kN and 300kN models. What Is a 200kN Anchor Pull-Out Tester? A 200kN anchor pull-out tester is a hydraulic testing instrument designed to apply and measure tensile force up to 200 kilonewtons. It is commonly used to evaluate installed anchoring systems under controlled tensile loading. Potential applications include: Anchor bolt testing Chemical anchor testing Mechanical anchor testing Expansion bolt testing Anchor rod testing Suitable steel bar testing Post-installed anchorage testing Faade anchor testing Curtain wall anchor testing Construction QA/QC Is 200kN the Same as 20 Tons? Approximately. 200kN ≈ 20.4 metric tonnes-force. For this reason, equipment in this range is commonly described commercially as a 20-ton anchor pull-out tester. However, engineering test requirements should normally be expressed and recorded using the appropriate force units specified by the project. Langry APT200 Technical Specifications SpecificationLangry APT200Measurement Range0200kNCapacity ClassApprox. 20 TonCylinder Centre Hole35mmCylinder Stroke70mmCylinder WeightApprox. 13kgCommon AnchorageΦ6Φ25Pull RodM24ConverterM6M22Data Storage500 RecordsContinuous Working Time>200 HoursAccuracy ClassificationEN ISO 7500-1 Class 1 These specifications make the APT200 suitable for a broad range of professional field-testing requirements. What Can a 200kN Pull-Out Tester Be Used For? Chemical Anchor Pull-Out Testing Chemical or bonded anchors can be tested where the project requires verification of installed anchorage performance. The test may be used to identify problems associated with factors such as: Hole preparation Embedment Adhesive installation Curing Concrete condition Workmanship Mechanical Anchor Testing Mechanical anchors, including suitable expansion-type fixings, can also require site pull-out testing. The performance of these installations may depend on: Drill diameter Embedment Installation torque Correct setting Base material Edge distance Workmanship Expansion Bolt Pull-Out Testing Expansion bolts are widely used for construction fixings. A pull-out tester allows a controlled tensile force to be applied to the installed anchor according to the approved test procedure. Steel Bar and Anchor Rod Testing The Langry APT series is also intended for suitable steel bar and anchor rod pull-out testing applications. The required test configuration depends on: Bar diameter Required load Connection method Exposed length Reaction setup Curtain Wall and Faade Anchor Testing Faade contractors may need to verify selected anchors used to connect brackets and supporting systems to the building structure. The APT200 can be used for suitable on-site pull-out testing arrangements where the required test load remains within its measurement capacity. Why Choose 200kN Instead of 100kN? A 100kN tester may be sufficient when all expected test loads remain below its maximum capacity. However, companies working on different construction projects may encounter higher test requirements. A 200kN tester provides additional range. This can be useful for: Testing companies serving multiple customers Contractors handling different anchor sizes Faade contractors working on different projects QA/QC teams requiring greater flexibility Companies planning to expand their testing capabilities Why Not Simply Buy a 300kN Tester? More capacity is not automatically better. A higher-capacity system may involve: Greater equipment size Additional weight Higher investment More difficult site handling If the company's normal test requirements remain below 200kN, a 200kN tester may provide a better balance between capacity and field usability. Langry APT100 vs APT200 vs APT300 ModelMaximum RangeApproximate ClassAPT100100kN10 TonAPT200200kN20 TonAPT300300kN30 Ton The correct model should be selected according to the maximum anticipated test requirement. Who Should Consider a 200kN Pull-Out Tester? The Langry APT200 may be suitable for: Main contractors Civil contractors Structural contractors Faade contractors Curtain wall contractors Steel contractors M&E contractors Anchor installation companies QA/QC departments Engineering consultants Inspection companies Testing laboratories Infrastructure contractors 200kN Tester for Construction QA/QC Anchor pull-out testing can form part of a broader construction quality-control process. A typical QA/QC workflow may include: Inspect anchor installation Identify test locations Confirm required proof load Set up the pull-out tester Apply controlled tensile load Monitor anchor behaviour Record the result Inspect after testing Prepare test documentation The actual procedure should follow the approved project requirements. 200kN Is Maximum Capacity Not the Required Test Load This is extremely important. Buying a 200kN pull-out tester does not mean every anchor should be tested to 200kN. For example, a project may specify a proof load substantially below 200kN. The required test load depends on: Anchor system Design requirement Anchor specification Base material Project specification Approved testing procedure The APT200 provides the measurement range. It does not determine the project's test load. How to Choose the Correct Anchor Pull-Out Tester Before purchasing, identify the following: 1. What are you testing? Chemical anchor, expansion bolt, steel bar or another anchoring system? 2. What is the required test load? This determines the minimum capacity required. 3. What is the anchor diameter? This helps determine the appropriate connection. 4. What is the thread size? The correct adapter or converter must be available. 5. How much anchor is exposed? There must be sufficient access for the pulling connection. 6. Where will testing be performed? Ground-level and elevated faade testing may have very different handling requirements. 7. What is the reaction arrangement? The hydraulic cylinder requires an appropriate and stable test setup. Why Digital Data Storage Is Useful The Langry APT series supports storage of up to 500 measurement records. This is useful when testing multiple anchors on the same project. However, digital force records should form only part of the complete QA/QC documentation. A professional test record may also need: Anchor ID Test location Required load Holding time Observations Pass/fail result Photographs Operator details What Should You Send When Requesting a Quotation? If you are looking for a 200kN anchor pull-out tester, send your supplier the following information: Anchor type Anchor diameter Thread size Required test load Maximum expected load Base material Application Site testing requirement This helps confirm whether the Langry APT200 is appropriate or whether another capacity should be considered. Frequently Asked Questions What is the capacity of the Langry APT200? The Langry APT200 provides a maximum measurement range of 200kN, approximately a 20-ton class capacity. Is 200kN enough for anchor pull-out testing? It depends on the project. If the maximum required test load is below 200kN and the test configuration is compatible, the APT200 may be suitable. Can the APT200 test chemical anchors? Yes, it can be used for suitable chemical anchor pull-out testing applications with the appropriate setup. Can it test expansion bolts? Suitable expansion bolts and mechanical anchoring components are among the applications of this type of pull-out tester. Can it be used for curtain wall anchor testing? Yes. The APT series is suitable for appropriate anchor testing applications associated with faade and curtain wall works. Does the tester record measurements? The Langry APT series supports storage of up to 500 measurement records. Is APT200 better than APT100? It provides twice the maximum measurement range. Whether that additional capacity is necessary depends on the user's test requirements. Should I buy APT200 or APT300? If your maximum required load remains below 200kN, APT200 may be sufficient. If testing needs can exceed 200kN, APT300 should be considered. 20 Ton Anchor Pull-Out Tester Supplier Malaysia MTM Precision supplies professional construction, civil engineering and testing instruments for customers throughout Malaysia. If you are searching for: 200kN Anchor Pull-Out Tester Malaysia 20 Ton Anchor Pull-Out Tester Malaysia Anchor Bolt Pull-Out Tester Malaysia Chemical Anchor Pull-Out Tester Malaysia Expansion Bolt Pull-Out Tester Malaysia Langry APT200 Malaysia contact MTM Precision with your required test load and anchor information. We can help identify whether the APT200 or another Langry APT model is more appropriate for your application. Contact MTM Precision MTM Precision Sdn. Bhd. Showroom & Service Centre No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia 🌐 Website: www.mtmpre.com.my 📧 Email: mtmpre@yahoo.com 📱 WhatsApp: +6016-660 7346 For Langry APT200 200kN / 20 Ton Anchor Pull-Out Tester Malaysia, quotation, model selection and construction testing equipment enquiries, contact MTM Precision.

11 Aug 2026