Anchor Pull-Out Tester for Testing Laboratory and Inspection Company Malaysia

Anchor Pull-Out Tester for Testing Laboratory and Inspection Company Malaysia


Professional Anchor Pull-Out Testing Equipment Malaysia


Testing laboratories and inspection companies often require more flexibility from an anchor pull-out tester than a contractor purchasing equipment for one specific project.


A professional testing company may receive enquiries involving different anchor types, diameters, applications and required test loads.


These can include:


Chemical anchors


Mechanical anchors


Expansion bolts


Anchor rods


Threaded rods


Post-installed steel bars


Façade anchors


Curtain wall anchors


Structural fixings


For this type of professional field testing, the Langry APT200 Anchor Pull-Out Tester provides a maximum measurement range of 0–200kN, approximately equivalent to a 20-ton class pull-out testing system.


Why Testing Companies Need Flexible Pull-Out Testing Equipment


A contractor may know exactly what anchor system is used on a particular project.


An independent testing company has a different challenge.


Today, the customer may request testing of an expansion bolt.


Tomorrow, another project may involve a chemical anchor.


The next enquiry may involve façade anchors or post-installed steel bars.


This means testing companies should consider not only today's application but also the range of work they expect to accept in the future.


Langry APT200 – 200kN Testing Capacity


The Langry APT200 provides:


Measurement Range: 0–200kN


This corresponds to approximately:


20-ton class capacity


The 200kN range can provide useful flexibility for laboratories and inspection companies whose test requirements may exceed the capacity of a smaller 100kN system.


Langry APT200 Technical Specifications


SpecificationLangry APT200Measurement Range0–200kNApproximate Capacity20 TonCylinder Centre Hole35mmCylinder Stroke70mmCylinder WeightApprox. 13kgCommon AnchorageΦ6–Φ25Pull RodM24ConverterM6–M22Data Storage500 RecordsContinuous Working Time>200 HoursAccuracy ClassificationEN ISO 7500-1 Class 1


These characteristics make the APT200 relevant to professional on-site anchor testing applications.


Why 200kN Can Be a Useful Range for Inspection Companies


An inspection company should consider the maximum test load it is likely to encounter.


A 100kN tester can be sufficient for lower-load applications.


However, once a customer's required test exceeds 100kN, that equipment no longer provides sufficient range.


The 200kN APT200 provides additional capacity without immediately moving to a 300kN system.


For companies serving multiple customers, this can expand the range of projects they are able to consider.


When Is 100kN Enough?


The Langry APT100 may be suitable when:


All expected test loads remain below 100kN


The company mainly handles lighter anchors


Portability is a high priority


Higher-load testing is rarely requested


If the testing laboratory knows its work will remain comfortably within this range, a 100kN model may be sufficient.


When Should a Testing Company Consider 300kN?


The Langry APT300 should be considered when the company's work can require test loads above 200kN.


This may apply to specialist companies handling heavier anchoring applications.


However, additional capacity should be purchased because it is genuinely required—not simply because 300kN is the largest option.


APT100 vs APT200 vs APT300 for Testing Companies


ModelMaximum RangeApproximate CapacityGeneral PositionAPT100100kN10 TonLower-load applicationsAPT200200kN20 TonBroad middle rangeAPT300300kN30 TonHigher-load applications


A laboratory should review its existing and anticipated customer requirements before choosing.


Chemical Anchor Testing Services


Testing companies may receive requests to verify chemical or bonded anchor installations.


The performance of these anchors can depend on:


Drilling


Hole diameter


Hole cleaning


Embedment depth


Adhesive installation


Adhesive curing


Concrete condition


Workmanship


Where required by the project, the tester can be used to apply the specified tensile test load to selected anchors.


Mechanical Anchor and Expansion Bolt Testing


Mechanical anchors may also require field verification.


Potential factors affecting performance include:


Hole diameter


Embedment


Installation torque


Expansion setting


Concrete condition


Edge distance


Anchor spacing


Installation workmanship


The Langry APT200 can be used for suitable pull-out testing configurations where the required load remains within 200kN.


Façade and Curtain Wall Inspection


Façade projects can create significant demand for anchor inspection and testing.


Testing companies may be appointed to verify selected anchors associated with:


Curtain wall brackets


Façade supports


Cladding systems


Chemical anchors


Expansion anchors


Structural fixings


Because test points may be spread throughout a building, portable field equipment is important.


Post-Installed Steel Bar Testing


Some construction and retrofit projects may require suitable post-installed steel bars or anchoring elements to undergo pull-out verification.


Before accepting such a job, the testing company should confirm:


Bar diameter


Required test load


Pulling connection


Available exposed length


Reaction arrangement


Project test method


The term “rebar pull-out test” can refer to different test objectives, so the exact requirement should always be clarified.


Measurement Accuracy Matters


Testing companies sell measurement and inspection services.


Therefore, equipment accuracy is an important consideration.


The Langry APT200 is specified with an:


EN ISO 7500-1 Class 1 accuracy classification


However, the testing company should still confirm any project-specific calibration and traceability requirements before performing the work.


Calibration Requirements for Professional Testing


Some customers may ask:


“Is your pull-out tester calibrated?”


Testing companies should be prepared for this question.


Depending on the project, documentation requirements may include:


Equipment identification


Serial number


Calibration certificate


Calibration date


Calibration validity


Measurement traceability


The exact requirement depends on the contract, project specification and customer's QA/QC procedure.


Why Calibration Records Matter


If a test result is challenged later, the testing company should be able to identify which instrument was used.


A professional report may therefore record:


Equipment manufacturer


Model


Serial number


Measurement range


Calibration information


Test date


This improves traceability.


Why Data Storage Is Useful for Testing Companies


The Langry APT series supports storage of up to 500 measurement records.


This is useful when testing many anchors during a project.


However, stored readings should not replace a complete test report.


The testing company may still need to record:


Project


Location


Anchor ID


Anchor type


Required load


Maximum applied load


Holding time


Observations


Result


Photographs


Test Reporting Is Part of the Service


A testing company does not simply provide a number.


Customers normally need a usable test record.


A professional anchor pull-out test report may include:


Project Details


Project name, location, contractor and test date.


Anchor Details


Type, diameter, installation and location.


Equipment Details


Tester model, serial number and calibration information where required.


Test Requirement


Specified proof load and loading procedure.


Results


Actual applied force and observations.


Acceptance


Pass/fail according to the defined project criteria.


Force Measurement Is Not the Same as Engineering Acceptance


This distinction is especially important for independent testing companies.


The instrument measures the force.


For example:


Maximum Applied Load: 125.6kN


But whether that anchor passes depends on the approved acceptance criteria.


The testing company should avoid inventing its own acceptance limit unless it is responsible and authorised to define the test method.


Proof Testing vs Ultimate Testing


Testing companies should establish the required test objective before mobilising to site.


Proof Test


The anchor is loaded to a predetermined level according to the approved procedure.


The objective is normally not to intentionally cause failure.


Ultimate Test


The test continues according to a defined method until a failure criterion is reached.


This may be destructive.


The equipment, safety controls and reporting requirements may differ significantly between these two test types.


Why Site Setup Matters


A laboratory-quality force indicator does not guarantee a good field test if the physical setup is poor.


The operator should consider:


Pulling alignment


Adapter connection


Reaction arrangement


Concrete condition


Anchor location


Edge distance


Available clearance


Safety zone


Good testing practice requires both suitable measurement equipment and an appropriate mechanical setup.


Importance of Operator Training


Professional testing equipment should be operated by personnel who understand:


Hydraulic loading


Test setup


Equipment limitations


Anchor connections


Force readings


Safety precautions


Test documentation


An experienced operator is particularly important when testing at high loads.


Safety for Professional Pull-Out Testing


A 200kN pull-out system can generate substantial tensile force.


Testing companies should establish appropriate safety procedures.


These may include:


Equipment inspection


Correct PPE


Controlled test area


Secure adapters


Proper alignment


Stable reaction setup


Exclusion from the potential failure path


Controlled pressure release


Safety should be considered during every test, regardless of whether the required load is below the maximum equipment capacity.


Building an Anchor Pull-Out Testing Service


For an inspection company considering adding anchor pull-out testing to its services, equipment selection is only one part of the setup.


The company should also consider:


Testing equipment


Required capacities


Adapters and accessories


Calibration


Operator training


Method statements


Safety procedures


Test report templates


Equipment maintenance


Customer application review


This creates a more professional service than simply purchasing a hydraulic tester.


Why APT200 May Be a Good Starting Point


For a testing company that expects a variety of normal construction anchor applications, the APT200 can be an attractive middle-capacity model.


It provides:


Up to 200kN measurement range


Approximately 20-ton class capacity


Digital force measurement


Data storage


Portable field use


More range than a 100kN system


However, companies expecting regular loads above 200kN should consider the APT300.


Can Anchor Pull-Out Testing Become a Service Business?


For inspection companies, the equipment can support paid testing services across different industries and projects.


Potential customers include:


Main contractors


Façade contractors


Structural contractors


M&E contractors


Anchor installers


Engineering consultants


Building owners


Infrastructure contractors


Companies that already provide construction inspection services may be able to integrate anchor pull-out testing into their existing QA/QC offering.


Questions to Ask a Customer Before Accepting a Test Job


Before mobilising equipment, ask:


What type of anchor is being tested?


What is the anchor diameter?


What is the required test load?


Is this proof testing or destructive testing?


What is the test method?


What are the acceptance criteria?


How many anchors need testing?


Where are the anchors located?


Is working at height required?


What report and calibration documents are required?


These questions can prevent major problems at the site.


Frequently Asked Questions


Is the Langry APT200 suitable for testing companies?


It can be a practical option for professional users requiring suitable anchor pull-out testing up to 200kN.


Why might a testing laboratory choose 200kN instead of 100kN?


The additional range allows the company to consider projects requiring loads above 100kN.


Does the APT200 store test readings?


The Langry APT series supports storage of up to 500 measurement records.


Is calibration important?


For professional testing services, calibration and measurement traceability may be required depending on the project or customer.


Can the APT200 test chemical anchors?


Yes, for suitable chemical anchor testing configurations within its capacity.


Can it be used for curtain wall inspection?


Yes. Pull-out testing can be applicable to suitable façade and curtain wall anchoring systems where specified.


Can a testing company decide whether an anchor passes?


The result should be evaluated against the approved project acceptance criteria. The force reading alone does not define pass or fail.


Where can a testing company buy the Langry APT200 in Malaysia?


Contact MTM Precision Sdn. Bhd. for Langry anchor pull-out testing equipment, quotations and model-selection assistance in Malaysia.


Anchor Pull-Out Testing Equipment Supplier Malaysia


MTM Precision supplies professional testing and measurement instruments for construction, civil engineering, inspection and industrial applications.


For testing laboratories and inspection companies, we recommend providing:


Anchor Type + Diameter + Maximum Required Test Load + Typical Application


This helps determine whether APT100, APT200 or APT300 provides the appropriate testing range.


Contact MTM Precision


MTM Precision Sdn. Bhd.


Showroom & Service Centre


No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia


🌐 Website: www.mtmpre.com.my

📧 Email: mtmpre@yahoo.com

📱 WhatsApp: +6016-660 7346


For Langry APT200 Anchor Pull-Out Tester for Testing Laboratory and Inspection Company Malaysia, current quotation, model selection and professional construction testing equipment enquiries, contact MTM Precision.



11 Aug 2026