Anchor Pull-Out Tester for Testing Laboratory and Inspection Company Malaysia
Anchor Pull-Out Tester for Testing Laboratory and Inspection Company Malaysia
Professional Anchor Pull-Out Testing Equipment Malaysia
Testing laboratories and inspection companies often require more flexibility from an anchor pull-out tester than a contractor purchasing equipment for one specific project.
A professional testing company may receive enquiries involving different anchor types, diameters, applications and required test loads.
These can include:
Chemical anchors
Mechanical anchors
Expansion bolts
Anchor rods
Threaded rods
Post-installed steel bars
Façade anchors
Curtain wall anchors
Structural fixings
For this type of professional field testing, the Langry APT200 Anchor Pull-Out Tester provides a maximum measurement range of 0–200kN, approximately equivalent to a 20-ton class pull-out testing system.
Why Testing Companies Need Flexible Pull-Out Testing Equipment
A contractor may know exactly what anchor system is used on a particular project.
An independent testing company has a different challenge.
Today, the customer may request testing of an expansion bolt.
Tomorrow, another project may involve a chemical anchor.
The next enquiry may involve façade anchors or post-installed steel bars.
This means testing companies should consider not only today's application but also the range of work they expect to accept in the future.
Langry APT200 – 200kN Testing Capacity
The Langry APT200 provides:
Measurement Range: 0–200kN
This corresponds to approximately:
20-ton class capacity
The 200kN range can provide useful flexibility for laboratories and inspection companies whose test requirements may exceed the capacity of a smaller 100kN system.
Langry APT200 Technical Specifications
SpecificationLangry APT200Measurement Range0–200kNApproximate Capacity20 TonCylinder Centre Hole35mmCylinder Stroke70mmCylinder WeightApprox. 13kgCommon AnchorageΦ6–Φ25Pull RodM24ConverterM6–M22Data Storage500 RecordsContinuous Working Time>200 HoursAccuracy ClassificationEN ISO 7500-1 Class 1
These characteristics make the APT200 relevant to professional on-site anchor testing applications.
Why 200kN Can Be a Useful Range for Inspection Companies
An inspection company should consider the maximum test load it is likely to encounter.
A 100kN tester can be sufficient for lower-load applications.
However, once a customer's required test exceeds 100kN, that equipment no longer provides sufficient range.
The 200kN APT200 provides additional capacity without immediately moving to a 300kN system.
For companies serving multiple customers, this can expand the range of projects they are able to consider.
When Is 100kN Enough?
The Langry APT100 may be suitable when:
All expected test loads remain below 100kN
The company mainly handles lighter anchors
Portability is a high priority
Higher-load testing is rarely requested
If the testing laboratory knows its work will remain comfortably within this range, a 100kN model may be sufficient.
When Should a Testing Company Consider 300kN?
The Langry APT300 should be considered when the company's work can require test loads above 200kN.
This may apply to specialist companies handling heavier anchoring applications.
However, additional capacity should be purchased because it is genuinely required—not simply because 300kN is the largest option.
APT100 vs APT200 vs APT300 for Testing Companies
ModelMaximum RangeApproximate CapacityGeneral PositionAPT100100kN10 TonLower-load applicationsAPT200200kN20 TonBroad middle rangeAPT300300kN30 TonHigher-load applications
A laboratory should review its existing and anticipated customer requirements before choosing.
Chemical Anchor Testing Services
Testing companies may receive requests to verify chemical or bonded anchor installations.
The performance of these anchors can depend on:
Drilling
Hole diameter
Hole cleaning
Embedment depth
Adhesive installation
Adhesive curing
Concrete condition
Workmanship
Where required by the project, the tester can be used to apply the specified tensile test load to selected anchors.
Mechanical Anchor and Expansion Bolt Testing
Mechanical anchors may also require field verification.
Potential factors affecting performance include:
Hole diameter
Embedment
Installation torque
Expansion setting
Concrete condition
Edge distance
Anchor spacing
Installation workmanship
The Langry APT200 can be used for suitable pull-out testing configurations where the required load remains within 200kN.
Façade and Curtain Wall Inspection
Façade projects can create significant demand for anchor inspection and testing.
Testing companies may be appointed to verify selected anchors associated with:
Curtain wall brackets
Façade supports
Cladding systems
Chemical anchors
Expansion anchors
Structural fixings
Because test points may be spread throughout a building, portable field equipment is important.
Post-Installed Steel Bar Testing
Some construction and retrofit projects may require suitable post-installed steel bars or anchoring elements to undergo pull-out verification.
Before accepting such a job, the testing company should confirm:
Bar diameter
Required test load
Pulling connection
Available exposed length
Reaction arrangement
Project test method
The term “rebar pull-out test” can refer to different test objectives, so the exact requirement should always be clarified.
Measurement Accuracy Matters
Testing companies sell measurement and inspection services.
Therefore, equipment accuracy is an important consideration.
The Langry APT200 is specified with an:
EN ISO 7500-1 Class 1 accuracy classification
However, the testing company should still confirm any project-specific calibration and traceability requirements before performing the work.
Calibration Requirements for Professional Testing
Some customers may ask:
“Is your pull-out tester calibrated?”
Testing companies should be prepared for this question.
Depending on the project, documentation requirements may include:
Equipment identification
Serial number
Calibration certificate
Calibration date
Calibration validity
Measurement traceability
The exact requirement depends on the contract, project specification and customer's QA/QC procedure.
Why Calibration Records Matter
If a test result is challenged later, the testing company should be able to identify which instrument was used.
A professional report may therefore record:
Equipment manufacturer
Model
Serial number
Measurement range
Calibration information
Test date
This improves traceability.
Why Data Storage Is Useful for Testing Companies
The Langry APT series supports storage of up to 500 measurement records.
This is useful when testing many anchors during a project.
However, stored readings should not replace a complete test report.
The testing company may still need to record:
Project
Location
Anchor ID
Anchor type
Required load
Maximum applied load
Holding time
Observations
Result
Photographs
Test Reporting Is Part of the Service
A testing company does not simply provide a number.
Customers normally need a usable test record.
A professional anchor pull-out test report may include:
Project Details
Project name, location, contractor and test date.
Anchor Details
Type, diameter, installation and location.
Equipment Details
Tester model, serial number and calibration information where required.
Test Requirement
Specified proof load and loading procedure.
Results
Actual applied force and observations.
Acceptance
Pass/fail according to the defined project criteria.
Force Measurement Is Not the Same as Engineering Acceptance
This distinction is especially important for independent testing companies.
The instrument measures the force.
For example:
Maximum Applied Load: 125.6kN
But whether that anchor passes depends on the approved acceptance criteria.
The testing company should avoid inventing its own acceptance limit unless it is responsible and authorised to define the test method.
Proof Testing vs Ultimate Testing
Testing companies should establish the required test objective before mobilising to site.
Proof Test
The anchor is loaded to a predetermined level according to the approved procedure.
The objective is normally not to intentionally cause failure.
Ultimate Test
The test continues according to a defined method until a failure criterion is reached.
This may be destructive.
The equipment, safety controls and reporting requirements may differ significantly between these two test types.
Why Site Setup Matters
A laboratory-quality force indicator does not guarantee a good field test if the physical setup is poor.
The operator should consider:
Pulling alignment
Adapter connection
Reaction arrangement
Concrete condition
Anchor location
Edge distance
Available clearance
Safety zone
Good testing practice requires both suitable measurement equipment and an appropriate mechanical setup.
Importance of Operator Training
Professional testing equipment should be operated by personnel who understand:
Hydraulic loading
Test setup
Equipment limitations
Anchor connections
Force readings
Safety precautions
Test documentation
An experienced operator is particularly important when testing at high loads.
Safety for Professional Pull-Out Testing
A 200kN pull-out system can generate substantial tensile force.
Testing companies should establish appropriate safety procedures.
These may include:
Equipment inspection
Correct PPE
Controlled test area
Secure adapters
Proper alignment
Stable reaction setup
Exclusion from the potential failure path
Controlled pressure release
Safety should be considered during every test, regardless of whether the required load is below the maximum equipment capacity.
Building an Anchor Pull-Out Testing Service
For an inspection company considering adding anchor pull-out testing to its services, equipment selection is only one part of the setup.
The company should also consider:
Testing equipment
Required capacities
Adapters and accessories
Calibration
Operator training
Method statements
Safety procedures
Test report templates
Equipment maintenance
Customer application review
This creates a more professional service than simply purchasing a hydraulic tester.
Why APT200 May Be a Good Starting Point
For a testing company that expects a variety of normal construction anchor applications, the APT200 can be an attractive middle-capacity model.
It provides:
Up to 200kN measurement range
Approximately 20-ton class capacity
Digital force measurement
Data storage
Portable field use
More range than a 100kN system
However, companies expecting regular loads above 200kN should consider the APT300.
Can Anchor Pull-Out Testing Become a Service Business?
For inspection companies, the equipment can support paid testing services across different industries and projects.
Potential customers include:
Main contractors
Façade contractors
Structural contractors
M&E contractors
Anchor installers
Engineering consultants
Building owners
Infrastructure contractors
Companies that already provide construction inspection services may be able to integrate anchor pull-out testing into their existing QA/QC offering.
Questions to Ask a Customer Before Accepting a Test Job
Before mobilising equipment, ask:
What type of anchor is being tested?
What is the anchor diameter?
What is the required test load?
Is this proof testing or destructive testing?
What is the test method?
What are the acceptance criteria?
How many anchors need testing?
Where are the anchors located?
Is working at height required?
What report and calibration documents are required?
These questions can prevent major problems at the site.
Frequently Asked Questions
Is the Langry APT200 suitable for testing companies?
It can be a practical option for professional users requiring suitable anchor pull-out testing up to 200kN.
Why might a testing laboratory choose 200kN instead of 100kN?
The additional range allows the company to consider projects requiring loads above 100kN.
Does the APT200 store test readings?
The Langry APT series supports storage of up to 500 measurement records.
Is calibration important?
For professional testing services, calibration and measurement traceability may be required depending on the project or customer.
Can the APT200 test chemical anchors?
Yes, for suitable chemical anchor testing configurations within its capacity.
Can it be used for curtain wall inspection?
Yes. Pull-out testing can be applicable to suitable façade and curtain wall anchoring systems where specified.
Can a testing company decide whether an anchor passes?
The result should be evaluated against the approved project acceptance criteria. The force reading alone does not define pass or fail.
Where can a testing company buy the Langry APT200 in Malaysia?
Contact MTM Precision Sdn. Bhd. for Langry anchor pull-out testing equipment, quotations and model-selection assistance in Malaysia.
Anchor Pull-Out Testing Equipment Supplier Malaysia
MTM Precision supplies professional testing and measurement instruments for construction, civil engineering, inspection and industrial applications.
For testing laboratories and inspection companies, we recommend providing:
Anchor Type + Diameter + Maximum Required Test Load + Typical Application
This helps determine whether APT100, APT200 or APT300 provides the appropriate testing range.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
For Langry APT200 Anchor Pull-Out Tester for Testing Laboratory and Inspection Company Malaysia, current quotation, model selection and professional construction testing equipment enquiries, contact MTM Precision.
11 Aug 2026