What Size Anchor Pull-Out Tester Do I Need? 100kN vs 200kN vs 300kN Malaysia

What Size Anchor Pull-Out Tester Do I Need? 100kN vs 200kN vs 300kN Malaysia


How to Select the Correct Anchor Pull-Out Tester Capacity Malaysia


One of the most common questions when buying an anchor pull-out tester is:


“What capacity do I need?”


Should you choose:


100kN?


200kN?


or


300kN?


The answer should be based primarily on the maximum required test load, together with the anchor type, test configuration and project requirements.


Langry offers three common capacities in its APT Anchor Pull-Out Tester series:


APT100 – 100kN / 10 Ton Class


APT200 – 200kN / 20 Ton Class


APT300 – 300kN / 30 Ton Class


For many mixed construction testing applications, the APT200 provides a practical middle-capacity option, but it is not automatically the correct choice for every user.


Quick Answer: What Size Pull-Out Tester Do I Need?


A simple starting guide is:


Maximum Required Test LoadModel to ConsiderUp to 100kNAPT100Above 100kN and up to 200kNAPT200Above 200kN and up to 300kNAPT300


However, this is only the first step.


You must also confirm:


Anchor type


Anchor diameter


Thread size


Pulling connection


Test setup


Site access


Required accessories


First Question: What Is Your Required Test Load?


This is the most important information.


Before buying a pull-out tester, obtain the required test load from the appropriate source.


This may be specified by:


Structural engineer


Project consultant


Approved method statement


Project specification


Anchor system requirements


QA/QC procedure


Do not guess the required load based only on anchor diameter.


What Does 100kN Mean?


A 100kN pull-out tester provides approximately:


10.2 metric tonnes-force


For commercial equipment selection, this is commonly referred to as a:


10 Ton Anchor Pull-Out Tester


The Langry model in this range is:


APT100


What Does 200kN Mean?


200kN corresponds to approximately:


20.4 metric tonnes-force


This is commonly referred to commercially as a:


20 Ton Anchor Pull-Out Tester


The Langry model is:


APT200


This model provides a useful middle range for users who require more than 100kN but do not normally need more than 200kN.


What Does 300kN Mean?


300kN corresponds to approximately:


30.6 metric tonnes-force


This is commonly referred to as a:


30 Ton Anchor Pull-Out Tester


The Langry model is:


APT300


It should be considered where test requirements can exceed the 200kN capacity of the APT200.


Should I Buy APT100?


Consider the Langry APT100 if:


Your maximum required load is below 100kN


You mainly test lighter anchors


Higher loads are unlikely


Portability is important


Your project scope is relatively consistent


If your work is clearly below 100kN, purchasing additional capacity may not be necessary.


Should I Buy APT200?


Consider the Langry APT200 if:


Your required loads may exceed 100kN


Maximum requirements remain within 200kN


You test different anchor types


You work on different construction projects


You want more flexibility than a 100kN tester


The APT200 can be particularly relevant for:


Contractors


QA/QC departments


Façade contractors


Anchor installers


Inspection companies


Testing laboratories


Should I Buy APT300?


Consider the Langry APT300 if:


Your required test load can exceed 200kN


You regularly handle heavier anchoring applications


200kN would restrict your service range


Your project specification requires higher testing capacity


Do not buy APT300 simply because it is the largest model.


Buy it when your application requires the additional range.


Should I Leave Extra Capacity?


It can be useful to consider future testing requirements.


For example:


If your maximum current test requirement is already close to 100kN and you expect larger projects in the future, the APT200 may provide additional flexibility.


However, this does not mean you should always select the next larger model.


Consider:


Current projects


Future projects


Frequency of testing


Equipment weight


Portability


Budget


Do I Choose Capacity Based on Anchor Diameter?


No.


Anchor diameter is important, but it does not directly tell you which tester capacity to purchase.


For example, two anchors of similar diameter may have different:


Anchor designs


Embedment depths


Base materials


Design loads


Test requirements


Therefore:


Anchor Diameter ≠ Required Test Load


Always confirm the actual test requirement.


What Size Tester for Chemical Anchors?


Chemical anchor test loads vary significantly.


The correct capacity depends on:


Threaded rod or bar diameter


Anchoring system


Embedment depth


Concrete


Required proof load


Project specification


Possible selection:


Below 100kN → APT100 may be sufficient


100–200kN → APT200 may be appropriate


Above 200kN → Consider APT300


The actual test method must still be confirmed.


What Size Tester for Expansion Bolts?


Mechanical anchor testing should also be selected according to required load.


Do not assume all expansion bolts need the same tester.


Check:


Bolt size


Anchor type


Installation


Required proof load


Concrete condition


Project specification


What Size Tester for Post-Installed Rebar?


Post-installed steel bar applications may involve higher tensile loads.


Before selecting equipment, confirm:


Bar diameter


Steel properties


Required test load


Anchoring system


Embedment


Test method


If the required load exceeds 100kN, the APT100 will not provide sufficient measurement range.


APT200 or APT300 should then be considered depending on the required load.


What Size Tester for Curtain Wall Anchors?


Curtain wall and façade projects can involve different anchoring systems.


These may include:


Chemical anchors


Expansion anchors


Mechanical anchors


Threaded rods


Façade brackets


There is no single capacity that applies to every curtain wall project.


The façade engineer's or project's required test load should determine the capacity.


What Size Tester for a Testing Laboratory?


Testing companies should think differently from contractors working on one project.


A laboratory may receive future jobs involving many different anchor systems.


It should consider:


Historical maximum test loads


Customer enquiries


Future service scope


Portability


Calibration requirements


Range of adapters


For a laboratory expecting varied medium-range work, the APT200 can provide greater flexibility than the APT100.


What Size Tester for a Contractor?


A contractor should review the types of projects it normally handles.


Mostly small anchor tests


APT100 may be enough.


Mixed construction projects


APT200 may provide more flexibility.


Regular high-load testing


APT300 may be required.


The correct answer depends on actual project data.


Why the APT200 Is an Important Middle Option


The Langry APT200 provides:


0–200kN measurement range


It offers substantially more range than the APT100 while remaining below the higher 300kN class.


Key APT200 specifications include:


SpecificationLangry APT200Measurement Range0–200kNApproximate Capacity20 TonCylinder Centre Hole35mmCylinder Stroke70mmCylinder WeightApprox. 13kgCommon AnchorageΦ6–Φ25Pull RodM24ConverterM6–M22Data Storage500 RecordsContinuous Working Time>200 HoursAccuracy ClassificationEN ISO 7500-1 Class 1


Capacity Is Not the Only Thing That Matters


Suppose your project requires 120kN.


You correctly identify that a 100kN tester is insufficient.


You purchase a 200kN tester.


But you still need to confirm:


Can the tester connect to the anchor?


Is the correct adapter available?


Is there enough exposed thread?


Can the cylinder fit the location?


Is the reaction setup suitable?


Capacity solves only one part of the equipment-selection problem.


Check the Pulling Connection


The Langry APT200 configuration includes:


M24 Pull Rod


and


M6–M22 Converters


Before purchasing, provide the supplier with your anchor details.


For special anchor configurations, additional review may be required.


Check the Cylinder Centre Hole


The APT200 has a:


35mm Cylinder Centre Hole


The pulling arrangement must be compatible with the cylinder and test geometry.


This is particularly important for unusual steel bars or anchor configurations.


Check the Cylinder Stroke


The APT200 provides:


70mm Cylinder Stroke


Cylinder stroke should be considered as part of the complete testing arrangement.


Consider Equipment Weight


The APT200 cylinder weighs approximately:


13kg


This matters when testing:


At height


On scaffolding


Across multiple floors


In restricted areas


On façade projects


Higher capacity is useful only if the equipment remains practical for your work.


Do Not Choose a Tester Based Only on Price


Suppose:


Tester A costs less but provides 100kN.


Tester B costs more but provides 200kN.


If your project requires 150kN, Tester A is not the cheaper option.


It is the wrong equipment.


Likewise, buying 300kN when your maximum requirement is only 50kN may provide little additional value.


Correct capacity comes first.


Five Questions Before Buying


Before asking for a quotation, answer these five questions:


1. What are you testing?


Chemical anchor, mechanical anchor, expansion bolt or steel bar?


2. What is the maximum required test load?


This determines the capacity.


3. What is the anchor diameter and thread?


This helps determine the connection.


4. Where will you perform the test?


Ground level, façade, confined area or laboratory?


5. What documentation does your project require?


Check calibration, reporting and traceability requirements.


Simple Buying Decision


If you tell MTM Precision:


“I need an anchor pull-out tester.”


we still need more information.


If you tell us:


Anchor: M16 Chemical Anchor


Required Load: 135kN


Application: Curtain Wall


we can immediately understand that a 100kN tester does not provide sufficient capacity and a higher-range model should be considered.


This is why application information is important.


Frequently Asked Questions


What size anchor pull-out tester do I need?


Choose according to the maximum required test load and confirm that the anchor connection and test setup are compatible.


Is 100kN enough?


It is sufficient only when your required test load remains within the 100kN range.


When should I choose 200kN?


Choose a 200kN-class tester when required loads can exceed 100kN but remain within 200kN.


When do I need 300kN?


Consider 300kN when the required test load can exceed 200kN.


Is 200kN approximately 20 tons?


Yes. 200kN corresponds to approximately 20.4 metric tonnes-force.


Is a bigger pull-out tester always better?


No. Higher capacity can mean additional weight, size and cost. Select equipment according to the actual application.


Can I choose the tester based on anchor diameter?


Not by diameter alone. Required test load is a more important capacity-selection factor.


Which Langry model is the middle capacity?


The Langry APT200, with a maximum measurement range of 200kN.


Where can I buy Langry APT100, APT200 or APT300 in Malaysia?


Contact MTM Precision Sdn. Bhd. for model selection, current quotation and Langry anchor pull-out testing equipment in Malaysia.


100kN, 200kN and 300kN Anchor Pull-Out Tester Supplier Malaysia


MTM Precision supplies professional construction and testing equipment for customers throughout Malaysia.


If you are unsure which Langry model to choose, send us:


Anchor Type + Anchor Diameter + Required Test Load + Application


We can help determine whether APT100, APT200 or APT300 is more suitable for your testing requirement.


Contact MTM Precision


MTM Precision Sdn. Bhd.


Showroom & Service Centre


No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia


🌐 Website: www.mtmpre.com.my

📧 Email: mtmpre@yahoo.com

📱 WhatsApp: +6016-660 7346


For 100kN, 200kN and 300kN Langry Anchor Pull-Out Tester Malaysia, model selection, current quotation and construction testing equipment enquiries, contact MTM Precision.



11 Aug 2026