How to Measure Solar Irradiance with TENMARS TM-751 Malaysia
How to Measure Solar Irradiance with TENMARS TM-751 Malaysia
Solar irradiance measurement is useful for solar PV installation, site inspection, panel positioning, maintenance and general solar energy assessment.
Instead of estimating sunlight intensity based only on weather conditions or visual observation, technicians can use a solar power meter such as the TENMARS TM-751 to obtain an actual solar radiation reading in W/m².
For solar contractors and engineers in Malaysia, understanding how to take consistent solar irradiance measurements can help improve site evaluation and troubleshooting.
What Is Solar Irradiance?
Solar irradiance describes the amount of solar power received over a particular surface area.
It is commonly expressed in:
W/m² — watts per square metre
The reading can change significantly depending on environmental and measurement conditions.
For example, solar irradiance measured under strong direct sunlight will normally be considerably higher than a measurement taken under heavy cloud cover.
Other factors such as panel orientation, shading and sensor angle can also affect the measurement.
Why Measure Solar Irradiance?
Solar PV systems depend on incoming solar energy.
When evaluating a photovoltaic installation, technicians may therefore need to understand whether the available sunlight at the time of inspection is sufficient for meaningful performance assessment.
Solar irradiance measurement can be useful for:
Solar PV site surveys
Installation checks
Panel orientation comparisons
Maintenance inspections
Performance troubleshooting
Shading investigation
Solar radiation surveys
Training and demonstration
Instead of simply recording that the weather is "sunny", the technician can record an actual irradiance value.
Using the TENMARS TM-751
The TENMARS TM-751 Solar Power Meter is designed for portable solar radiation measurements.
It offers a measurement range of up to:
2000 W/m²
with a resolution of:
0.1 W/m²
Its approximately 0.25-second sampling rate also allows technicians to observe changes in solar radiation relatively quickly while adjusting the measurement position.
This is particularly useful when comparing different panel angles or locations.
Step 1: Select a Suitable Measurement Location
Before taking the reading, identify the location that represents the condition you want to evaluate.
For solar PV applications, this will normally be near the solar panel array or installation area.
Avoid unintentionally positioning the meter where nearby structures create shadows that are not representative of the panel conditions.
Possible sources of shading include:
Roof structures
Water tanks
Trees
Utility poles
Antennas
Adjacent buildings
HVAC equipment
If shading itself is what you are investigating, take measurements at both shaded and unshaded locations for comparison.
Step 2: Position the Sensor Correctly
Sensor orientation is important when measuring solar radiation.
For a general sunlight measurement, expose the sensor directly to the sunlight according to the instrument's operating requirements.
For solar PV comparison work, positioning the sensor in approximately the same plane as the solar panel can provide a more relevant comparison with the radiation reaching the panel surface.
Small changes in angle may produce different readings.
Therefore, technicians should maintain consistent sensor positioning when comparing multiple locations or panels.
Step 3: Allow the Reading to Stabilise
Once the sensor is positioned, observe the display.
Sunlight can fluctuate because of moving clouds, atmospheric conditions and shadows.
Rather than recording a rapidly changing instantaneous value without context, allow the measurement to stabilise sufficiently for the application.
If conditions are changing quickly, record several readings.
For example:
Measurement 1: 820 W/m²
Measurement 2: 845 W/m²
Measurement 3: 831 W/m²
This provides more useful information than simply describing the conditions as "bright sunlight".
Step 4: Record the Measurement Conditions
A W/m² reading becomes more valuable when accompanied by basic site information.
Consider recording:
Solar irradiance reading
Date
Time
Location
Weather condition
Panel orientation
Panel angle
Shading condition
Relevant system measurements
This allows technicians to compare measurements taken during future maintenance visits.
Step 5: Compare Different Solar Panel Positions
One useful application of the TENMARS TM-751 is comparing solar radiation at different angles.
For example, a technician can measure irradiance at one panel orientation and then repeat the measurement at another orientation.
If the first position measures:
650 W/m²
and another position measures:
890 W/m²
under otherwise similar conditions, the difference indicates that the second orientation is receiving greater solar radiation at that particular time.
However, a single measurement should not be treated as the complete basis for designing a solar PV system.
Solar position changes throughout the day and year.
Professional system design should also consider long-term solar data, site geometry, shading and other engineering factors.
Using Irradiance Measurements for Solar PV Troubleshooting
Solar irradiance measurements can also provide useful context during photovoltaic troubleshooting.
Imagine a technician measures lower-than-expected PV output.
Without measuring sunlight, it may be difficult to determine whether the lower output is associated with:
Low solar radiation
Cloud cover
Shading
Dirty panels
Electrical problems
Panel problems
Inverter issues
System configuration
Measuring solar irradiance does not identify every fault automatically.
However, it provides an important environmental reference.
If solar irradiance is low, reduced PV output may be expected.
If solar irradiance is strong but system output is unexpectedly poor, further electrical and system investigation may be required.
Irradiance and Shading Inspection
Partial shading can significantly influence solar PV performance.
The TENMARS TM-751 can be used to compare solar radiation between different positions around an installation.
For example, technicians can compare:
Unshaded location → W/m²
versus
Partially shaded location → W/m²
This provides measurable evidence of the difference in solar exposure.
It can be useful when investigating roofs affected by trees, nearby buildings or rooftop equipment.
Why Time of Measurement Matters
Solar irradiance changes throughout the day.
A reading taken at 9:00 AM cannot automatically be compared directly with another reading taken at 1:00 PM without considering the different solar conditions.
For better comparative measurements, technicians should try to keep test conditions as consistent as practical.
This is especially important when comparing:
Different panels
Different roof areas
Different panel angles
Different solar films
Different glass samples
Consistent testing produces more meaningful results.
Can a Lux Meter Measure Solar Irradiance?
A lux meter and a solar power meter measure different quantities.
A lux meter measures illuminance, normally expressed in lux.
The TENMARS TM-751 measures solar radiation intensity in W/m².
Therefore, users evaluating solar energy should select an instrument designed for solar radiation measurement rather than assuming that a lux value can directly replace an irradiance measurement.
Applications Beyond Solar Panels
Although solar PV is an important application, the TENMARS TM-751 can also be used for comparative solar measurements involving:
Automotive windows
Window tint
Solar control films
Building glass
Transparent glass
Coated glass
Solar transmission demonstrations
For example, readings can be compared before and after solar radiation passes through a piece of treated glass.
This makes the instrument relevant beyond the photovoltaic industry.
Common Solar Irradiance Measurement Mistakes
Several simple mistakes can make measurements less useful.
Avoid:
Accidentally shading the sensor with your body
Changing sensor angles during comparison tests
Comparing measurements taken under very different weather conditions
Taking readings at different locations without recording them
Confusing W/m² with lux
Assuming one instantaneous reading represents the entire day's solar conditions
Good measurement practice is just as important as selecting the correct instrument.
TENMARS TM-751 for Solar Measurement in Malaysia
Malaysia's strong sunlight and expanding use of rooftop photovoltaic systems create many applications for portable solar measurement instruments.
The TENMARS TM-751 Solar Power Meter provides engineers, technicians and solar contractors with a straightforward method of measuring solar irradiance directly at the work site.
For installation, inspection, troubleshooting or solar radiation comparison, recording actual W/m² values provides more useful information than relying on visual judgement alone.
Looking for TENMARS TM-751 Solar Power Meter in Malaysia?
MTM Precision supplies professional testing and measurement instruments for solar, electrical, environmental and industrial applications.
Contact our team for product enquiries and assistance selecting a suitable solar measurement instrument for your application.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
13 Aug 2026