TENMARS TM-751 for Solar Panel Installation and Angle Testing Malaysia

TENMARS TM-751 for Solar Panel Installation and Angle Testing Malaysia

 

Solar panel performance depends not only on the photovoltaic module itself but also on how much solar radiation reaches its surface.

 

Panel orientation, tilt angle, surrounding buildings, trees, rooftop structures and changing weather conditions can all influence the amount of sunlight available at a solar PV installation.

 

The TENMARS TM-751 Solar Power Meter provides solar installers and technicians with a portable method of measuring solar radiation in W/m² directly at the site.

 

With measurements taken at different positions and angles, technicians can obtain useful field data when evaluating solar exposure.

 

Why Solar Panel Angle Matters

 

A photovoltaic panel produces electricity from incoming solar radiation.

 

However, the amount of solar radiation reaching the panel surface changes according to the relationship between the sun and the panel.

 

If sunlight reaches the panel at a more favourable angle, the solar radiation received by the surface may be higher.

 

If the panel orientation is less favourable, the effective solar energy reaching the surface can be lower.

 

This is why panel orientation and tilt are important considerations in solar PV installation.

 

Measuring Solar Radiation Instead of Guessing

 

Technicians can visually estimate whether an area receives strong sunlight, but visual judgement does not provide a measurable value.

 

The TENMARS TM-751 provides solar radiation measurements in:

 

W/m² — watts per square metre

 

Its measurement range extends up to 2000 W/m², with 0.1 W/m² resolution.

 

This gives technicians an actual measurement that can be recorded and compared.

 

For example, instead of writing:

 

"Roof Area A has better sunlight."

 

a technician can record:

 

Roof Area A: 910 W/m²

Roof Area B: 675 W/m²

 

The measurements provide additional evidence when comparing solar exposure under similar conditions.

 

Using the TM-751 During Solar Site Inspection

 

Before installing a photovoltaic system, a contractor may need to inspect different areas of the roof.

 

Potential installation locations can be affected by:

 

Adjacent buildings

 

Trees

 

Water tanks

 

Air-conditioning equipment

 

Roof structures

 

Antennas

 

Parapet walls

 

Utility infrastructure

 

A solar power meter can be used as a supporting instrument during this inspection.

 

Measurements can be taken at several locations to identify differences in solar exposure.

 

Comparing Different Panel Angles

 

One application of the TENMARS TM-751 is finding a suitable incident angle for solar panels.

 

The technician can position the solar power meter at different angles and observe how the W/m² reading changes.

 

For example:

 

Position A — 730 W/m²

Position B — 815 W/m²

Position C — 905 W/m²

 

Under sufficiently similar sunlight conditions, Position C is receiving the highest solar radiation at that moment.

 

This type of comparison can help technicians understand how orientation influences incoming solar energy.

 

Keep the Test Conditions Consistent

 

When comparing different angles, the measurements should be taken as close together in time as practical.

 

This is important because sunlight can change quickly.

 

Cloud movement alone can cause the irradiance reading to change significantly.

 

For meaningful comparisons:

 

Use the same meter.

 

Keep the measurement location consistent.

 

Change only the angle being evaluated where possible.

 

Take the readings within a short period.

 

Avoid comparisons when sunlight is changing rapidly.

 

Record the weather conditions.

 

Consistent measurement methods improve the usefulness of the results.

 

Solar Panel Angle Changes Throughout the Day

 

There is no single instantaneous measurement that represents solar conditions for the entire year.

 

The sun's position changes throughout the day and also varies seasonally.

 

A panel angle producing the highest irradiance reading at one particular moment may not automatically represent the optimum annual system design.

 

Therefore, TM-751 measurements should be considered as field measurement data, not a replacement for professional photovoltaic system design.

 

Solar contractors should also consider:

 

Historical solar radiation data

 

Geographic location

 

Roof orientation

 

Seasonal solar position

 

Shading analysis

 

System design

 

Module specifications

 

Engineering requirements

 

The TM-751 provides another useful measurement input during this process.

 

Checking Shading Around Solar Panels

 

Shading is an important issue for photovoltaic installations.

 

Even when a roof appears generally exposed to sunlight, certain areas may experience partial shading at different times.

 

Potential sources include trees, walls, adjacent buildings and rooftop equipment.

 

Technicians can take solar radiation measurements at multiple locations.

 

For example:

 

Open roof area: 950 W/m²

 

Area near rooftop structure: 610 W/m²

 

The difference provides an indication of the solar exposure at those two positions under the test conditions.

 

This can help support further shading assessment.

 

Using the TM-751 During Installation

 

The solar power meter can also be used while the installation is being carried out.

 

Technicians may use it to:

 

Check incoming solar radiation

 

Compare panel orientations

 

Evaluate different roof positions

 

Record site conditions

 

Support commissioning measurements

 

Document environmental conditions

 

The instrument's portable design makes it suitable for technicians moving around a rooftop or solar installation.

 

Using Solar Irradiance During Maintenance

 

Solar irradiance measurement remains useful after installation.

 

Consider a solar PV system that appears to be producing less power than expected.

 

The technician needs context.

 

If solar irradiance is only:

 

250 W/m²

 

then low PV output may be expected.

 

If solar irradiance is:

 

950 W/m²

 

but system output is still unusually low, further investigation may be justified.

 

Possible areas for inspection could include:

 

Module contamination

 

Partial shading

 

Module condition

 

Cable connections

 

Electrical faults

 

Inverter operation

 

System configuration

 

The solar power meter does not diagnose these problems by itself.

 

Instead, it provides a solar radiation reference that helps technicians interpret other measurements.

 

Solar Irradiance and Electrical Measurements

 

Professional solar PV troubleshooting often involves more than one instrument.

 

A solar technician may need to evaluate both environmental and electrical parameters.

 

Depending on the work, this could include measurements such as:

 

Solar irradiance

 

DC voltage

 

DC current

 

AC voltage

 

AC current

 

Temperature

 

Insulation resistance

 

Electrical continuity

 

The TENMARS TM-751 focuses specifically on solar radiation measurement.

 

Combining irradiance information with appropriate electrical measurements can provide a more complete picture of PV system operating conditions.

 

Fast Response for Field Comparison

 

The TM-751 has an approximately 0.25-second sampling rate.

 

This is useful when technicians need to observe changes while adjusting the sensor position or angle.

 

Instead of waiting for a lengthy measurement cycle, the operator can quickly see how the displayed irradiance changes.

 

This is particularly convenient for comparative field measurements.

 

Suitable Users in Malaysia

 

The TENMARS TM-751 may be useful for:

 

Solar PV installers

 

Solar EPC contractors

 

Electrical contractors

 

Solar maintenance companies

 

Facility management teams

 

Building maintenance departments

 

Engineering consultants

 

Technical colleges

 

Universities

 

Renewable energy training centres

 

It can also be useful as a demonstration instrument when teaching the relationship between panel angle and incoming solar radiation.

 

Solar Measurement for Commercial and Industrial Rooftops

 

Commercial and industrial buildings in Malaysia increasingly use rooftop solar installations.

 

These projects can involve large roof areas with different orientations and potential shading obstacles.

 

A portable solar power meter allows technicians to take quick measurements at different points around the installation.

 

For example, measurements can be taken near:

 

Different solar arrays

 

Roof edges

 

Water tanks

 

HVAC systems

 

Adjacent structures

 

Areas suspected of shading

 

The results can then be recorded as part of an inspection or maintenance report.

 

Is the TM-751 a Complete Solar PV Analyser?

 

No.

 

The TENMARS TM-751 is a solar power meter.

 

Its role is to measure solar radiation intensity.

 

A complete solar PV assessment may require additional instruments and analysis depending on the application.

 

The advantage of the TM-751 is its simplicity: when the technician needs an immediate solar irradiance measurement in W/m², the instrument provides a direct and portable solution.

 

A Useful Supporting Tool for Solar Contractors

 

For solar contractors, measurements are more useful than assumptions.

 

The TENMARS TM-751 can help transform observations such as "strong sunlight", "partial shade" or "better panel angle" into measurable solar irradiance values.

 

This can support:

 

Site surveys

 

Installation

 

Angle comparison

 

Shading investigation

 

Commissioning

 

Maintenance

 

Troubleshooting

 

For Malaysia's growing solar PV industry, a portable solar radiation meter can therefore be a useful addition to a technician's field measurement equipment.

 

Looking for TENMARS TM-751 Solar Power Meter in Malaysia?

 

MTM Precision supplies professional testing and measurement instruments for solar PV, electrical, environmental and industrial applications in Malaysia.

 

Contact us for enquiries on the TENMARS TM-751 Solar Power Meter and other instruments suitable for solar installation, inspection and maintenance.

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd.

 

Showroom & Service Centre

 

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia

 

🌐 Website: www.mtmpre.com.my

📧 Email: mtmpre@yahoo.com

📱 WhatsApp: +6016-660 7346


 

13 Aug 2026