How to Check Solar Film Effectiveness Using TENMARS TM-751 Solar Power Meter Malaysia
How to Check Solar Film Effectiveness Using TENMARS TM-751 Solar Power Meter Malaysia
Solar film is widely used on automotive and building windows in Malaysia, where strong sunlight can contribute to heat and discomfort inside vehicles, offices, shops and homes.
But how can an installer demonstrate the difference between solar films using actual measurements?
One practical method is to compare solar radiation before and after it passes through the film or treated glass.
The TENMARS TM-751 Solar Power Meter is designed to measure solar radiation intensity in W/m², making it suitable for comparative solar film testing and demonstrations.
What Are You Measuring?
Before performing a test, it is important to understand what the instrument measures.
The TENMARS TM-751 measures solar radiation intensity.
Its measurement range is up to:
2000 W/m²
with a resolution of:
0.1 W/m²
The instrument can therefore show how much solar radiation reaches the sensor under a particular test condition.
This allows users to compare readings taken with and without a solar film or glass sample.
Basic Solar Film Testing Principle
The basic idea is simple:
Measurement A — Without Solar Film
Compare it with:
Measurement B — With Solar Film
If significantly less solar radiation reaches the sensor during the second measurement, the meter will show a lower W/m² reading.
For example:
Without Film: 900 W/m²
With Film: 420 W/m²
This demonstrates a measurable difference under those particular test conditions.
Step 1: Prepare the Solar Power Meter
Before starting the comparison, ensure the TENMARS TM-751 is ready for measurement.
The sensor should be clean and unobstructed.
Choose a location where the solar radiation is sufficiently stable for a meaningful comparison.
Direct outdoor sunlight can be used when conditions are suitable, but rapidly moving clouds may make comparative testing more difficult.
Step 2: Take the Reference Measurement
Start by measuring the solar radiation without the film blocking the sensor.
Position the meter consistently and record the reading.
For example:
Reference Solar Radiation: 935 W/m²
This becomes the baseline for the comparison.
Also record basic information such as:
Time
Weather
Sensor position
Sensor angle
Test location
This helps improve measurement consistency.
Step 3: Introduce the Solar Film
Next, position the solar film between the incoming sunlight and the measurement sensor.
Try not to change the sensor location or angle.
The purpose is to keep the test setup as similar as possible while changing primarily the film being evaluated.
For example, the second measurement might be:
Solar Radiation Through Film: 455 W/m²
The difference between the reference and film measurements provides a practical demonstration of reduced solar radiation reaching the sensor.
Step 4: Repeat the Measurement
Do not rely automatically on a single measurement.
Repeat the test several times.
For example:
Reference: 930 W/m²
Film A: 470 W/m²
Repeat:
Reference: 925 W/m²
Film A: 465 W/m²
If the readings remain reasonably consistent, confidence in the comparison improves.
If the readings change dramatically, check whether clouds, sensor movement or other environmental factors are affecting the test.
Step 5: Compare Different Solar Films
Once a consistent test method has been established, different film samples can be compared.
For example:
Test ConditionSolar RadiationNo Film940 W/m²Film A610 W/m²Film B490 W/m²Film C360 W/m²
Under this example test setup, Film C allows the lowest measured solar radiation to reach the sensor.
However, this should be described as a comparative field measurement, not automatically treated as the manufacturer's certified film specification.
Why Test Conditions Must Remain Consistent
Comparative measurements are useful only when the conditions are reasonably similar.
Solar radiation can change because of:
Cloud movement
Time
Sensor angle
Sensor position
Shadows
Reflections
Film position
Glass angle
If the reference reading is taken during strong sunlight and the film reading is taken when a cloud passes over, the comparison will be misleading.
Therefore, measurements should be taken as close together in time as practical.
Avoid Shading the Sensor
One surprisingly common measurement error is caused by the person performing the test.
Your hand, body or test sample holder can unintentionally shade the sensor.
This can cause the W/m² reading to drop even when the film itself is not responsible for the entire reduction.
During testing, check that the sensor receives solar radiation through the intended test path without accidental obstruction.
Testing Film Installed on Automotive Glass
The same principle can be applied to vehicle windows.
A technician can compare measurements associated with:
Untinted glass
Existing tint
New solar film
Different vehicle windows
Different film specifications
However, automotive glass itself may already affect solar transmission.
Therefore, a measurement through glass + film should not automatically be interpreted as the performance of the film alone.
The complete test configuration should always be recorded.
Testing Building Window Film
Solar control film is also widely used in buildings.
Possible applications include:
Office windows
Retail storefronts
Residential windows
Factory offices
Showrooms
Hotels
Schools
Commercial buildings
Installers can perform before-and-after comparisons to demonstrate changes in solar radiation reaching the interior side of the glass.
This can provide useful supporting information during a site demonstration.
Can You Calculate a Reduction Percentage?
For a simple comparative test, users may calculate the reduction between the reference and measured values.
For example:
Reference = 1000 W/m²
After Film = 400 W/m²
Difference:
1000 − 400 = 600 W/m²
Simple measured reduction relative to the reference:
600 ÷ 1000 × 100 = 60%
Under those specific test conditions, the measured solar radiation reaching the sensor was approximately 60% lower.
However, this should not automatically be advertised as the film's certified solar rejection specification.
Certified product performance may involve defined laboratory methods, spectral measurements and applicable standards.
Solar Power Measurement Is Not the Same as VLT
Automotive tint customers frequently discuss VLT — Visible Light Transmission.
VLT describes how much visible light passes through the glass or film.
The TENMARS TM-751 is a solar power meter, not a dedicated VLT meter.
Therefore:
Solar radiation measurement ≠ VLT measurement
If the objective is to verify visible light transmission for regulatory or specialised automotive testing, an appropriate VLT measurement instrument should be used.
This distinction is important when selecting testing equipment.
Solar Radiation Is Also Different from Temperature
Another common misunderstanding is assuming that a solar power meter directly measures heat rejection.
The TM-751 measures solar radiation intensity in W/m².
It does not directly measure:
Cabin temperature
Glass temperature
Surface temperature
Air temperature
Temperature measurements require an appropriate thermometer, temperature probe or infrared thermometer depending on the application.
Using the correct terminology makes demonstrations more technically credible.
How Tint Shops Can Use the TM-751
Automotive tint businesses can use the instrument as part of a product demonstration.
For example, a salesperson can show:
Step 1: Reference solar radiation.
Step 2: Reading through an entry-level film.
Step 3: Reading through a higher-performance film.
Instead of relying entirely on statements such as "this film is much better", the customer sees actual measurement differences under the demonstration conditions.
This can create a more professional sales experience.
Useful for Solar Film Suppliers
Film distributors can also use comparative measurements when:
Training dealers
Demonstrating new products
Comparing product ranges
Conducting internal evaluations
Supporting technical presentations
A portable instrument makes it easier to perform demonstrations outside a laboratory environment.
Common Mistakes When Testing Solar Film
Avoid these common problems:
Changing the sensor angle between tests
Testing during rapidly changing sunlight
Accidentally shading the sensor
Comparing measurements taken at very different times
Confusing solar radiation with VLT
Confusing W/m² with lux
Treating field measurements as certified laboratory results
Using only one measurement without repetition
A simple test becomes much more useful when it is performed consistently.
Field Comparison vs Laboratory Certification
The TENMARS TM-751 is valuable for practical measurements, demonstrations and comparative testing.
However, there is an important distinction between:
Field comparison
and
Certified laboratory testing
Laboratory evaluation of window films may involve controlled light sources, specialised spectrophotometers, defined wavelength ranges and standardised procedures.
A handheld solar power meter should not be presented as a replacement for those methods.
Its strength is portability and practical real-world comparison.
Who Can Benefit from Solar Film Testing?
The TENMARS TM-751 may be useful for:
Automotive tint shops
Solar film installers
Window film distributors
Glass contractors
Automotive accessory companies
Building maintenance teams
Facility managers
Technical training centres
Engineering educators
Solar PV contractors
This gives the instrument applications across several industries.
Make Solar Film Demonstrations More Measurable
Customers increasingly expect technical products to be supported by measurable information.
A solar film demonstration based only on appearance can be subjective.
Adding a solar radiation measurement provides another layer of information.
With the TENMARS TM-751 Solar Power Meter, installers can compare solar radiation before and after different films or glass configurations and display the results directly in W/m².
For automotive tint shops and building window film contractors in Malaysia, this provides a simple way to make demonstrations more technical, measurable and professional.
Looking for TENMARS TM-751 Solar Power Meter in Malaysia?
MTM Precision supplies professional testing and measurement instruments for solar, automotive, building, environmental and industrial applications.
Contact us for enquiries about the TENMARS TM-751 Solar Power Meter for solar film testing, automotive window comparison, glass testing and solar radiation measurement in Malaysia.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
13 Aug 2026