How to Use TENMARS TM-4002 Hot Wire Anemometer Malaysia
How to Use TENMARS TM-4002 Hot Wire Anemometer Malaysia
The TENMARS TM-4002 Hot Wire Anemometer is designed for professional airflow and environmental measurement applications including HVAC testing, ventilation inspection, air balancing and facility maintenance.
Unlike a basic wind speed meter, the TM-4002 combines air velocity, CFM/CMM air volume, temperature, relative humidity, dew point and wet bulb temperature measurements with a telescopic hot wire probe.
Understanding the correct measurement procedure helps users obtain more useful and consistent readings.
What Can the TENMARS TM-4002 Measure?
The TM-4002 provides several HVAC-related measurements:
Air velocity
Air volume
Air temperature
Relative humidity
Dew point
Wet bulb temperature
Air velocity can be displayed in:
m/s
ft/min
km/hr
mph
knots
Air volume can be displayed in:
CFM
CMM
This makes the TM-4002 suitable for both airflow measurement and broader HVAC environmental inspection.
Step 1 – Inspect the Probe Before Measurement
Before taking measurements, check that the hot wire probe is clean and undamaged.
The sensing element is an important part of the instrument and should be handled carefully.
Avoid unnecessary physical contact with the sensing area.
For professional field instruments, good probe handling helps maintain reliable measurement performance.
Step 2 – Extend the Telescopic Probe
The TM-4002 features a telescopic probe that extends approximately from:
400 mm to 1020 mm
Adjust the probe length according to the measurement location.
For an easily accessible air outlet, the full length may not be required.
For measurements deeper inside HVAC ductwork, the extended probe provides additional reach.
Step 3 – Select the Required Air Velocity Unit
Choose the appropriate measurement unit according to your application.
For many Malaysian engineering applications, m/s is commonly convenient.
Other available units allow technicians to work with different project specifications or reporting formats.
Step 4 – Position the Sensor in the Airflow
Correct sensor positioning is important.
Place the hot wire sensor in the airflow according to the instrument's indicated airflow direction.
Incorrect orientation can affect the reading.
When measuring inside a duct, avoid allowing the probe to touch internal surfaces unnecessarily.
Step 5 – Allow the Reading to Stabilize
Do not immediately record the first number displayed.
Airflow can fluctuate, particularly inside ventilation systems.
Hold the sensor steadily and allow sufficient time for the reading to become reasonably stable.
The HOLD function can then be useful when recording the result.
Step 6 – Take Measurements at Multiple Points
One of the most important rules in HVAC airflow testing is:
Do not assume one measurement represents the entire duct.
Air velocity may vary across a duct because of:
Duct geometry
Bends
Dampers
Obstructions
Turbulence
Fan conditions
Depending on the required testing method, measurements may need to be taken at several points.
Step 7 – Measure CFM or CMM Air Volume
When air volume is required, determine the relevant duct or outlet area.
The TM-4002 supports:
CFM – Cubic Feet per Minute
CMM – Cubic Metres per Minute
The correct area value is important because an incorrect area will result in an incorrect air volume calculation.
This function is particularly useful for HVAC air balancing and ventilation assessment.
Step 8 – Check Temperature and Humidity
Airflow is only one part of HVAC performance.
The TM-4002 also measures:
Air Temperature
and
Relative Humidity
These measurements can help technicians evaluate the environmental condition of the air being supplied to a room or building zone.
Step 9 – Check Dew Point and Wet Bulb
The TM-4002 additionally provides:
Dew point
Wet bulb temperature
These parameters provide additional information about moisture conditions and are useful in various HVAC and environmental applications.
Step 10 – Store Measurement Data
The TM-4002 provides 99 sets of manual data memory.
This is useful when measurements need to be taken at multiple locations, such as:
Room 1
Room 2
Room 3
Supply duct
Return duct
Different diffusers
Different HVAC zones
Instead of depending entirely on handwritten notes during measurement, readings can be stored for reference during the inspection.
Using MAX, MIN and HOLD
The TM-4002 also provides useful field measurement functions.
MAX
Useful for identifying the highest observed reading during a measurement period.
MIN
Useful for identifying the lowest observed reading.
HOLD
Freezes the displayed reading so the technician can record or review the value more easily.
These functions can be particularly helpful when the display is difficult to observe while the probe is positioned inside a duct.
How to Measure an HVAC Duct
A practical duct measurement procedure may involve:
Select an appropriate measurement location.
Extend the telescopic probe.
Insert the sensor into the duct.
Position it correctly relative to airflow.
Allow the reading to stabilize.
Take measurements at the required points.
Record the readings.
Calculate or measure CFM/CMM where required.
Compare results with the project's required airflow values.
Always follow the relevant project specification or HVAC testing procedure.
Common Measurement Mistakes
Incorrect technique can produce misleading results.
Avoid common mistakes such as:
Incorrect sensor orientation
Measuring immediately after switching measurement locations
Taking only one reading in a large duct
Measuring too close to strong turbulence where avoidable
Using an incorrect duct area for CFM/CMM
Touching or damaging the sensing element
Comparing readings taken under very different HVAC operating conditions
Consistent measurement technique improves the usefulness of the collected data.
Where Can TM-4002 Be Used?
Typical applications include:
HVAC duct testing
Air balancing
Air-conditioning maintenance
Ventilation inspection
Cleanrooms
Laboratories
Facility management
Commercial buildings
Factories
Hospitals
Hotels
Shopping malls
Data centres
Industrial ventilation systems
Why Choose TENMARS TM-4002?
The advantage of the TM-4002 is not simply that it measures wind speed.
It combines:
0.01–25.00 m/s Air Velocity
CFM/CMM Air Volume
Temperature
Relative Humidity
Dew Point
Wet Bulb Temperature
400–1020 mm Telescopic Hot Wire Probe
99 Sets Manual Data Memory
For HVAC technicians and facility maintenance professionals, this combination makes it a practical multi-function airflow measurement instrument.
TENMARS TM-4002 Hot Wire Anemometer Malaysia
For professional HVAC, ventilation, air balancing and facility maintenance applications, the TENMARS TM-4002 Hot Wire Anemometer provides the measurement functions needed for detailed airflow assessment.
For enquiries regarding the TENMARS TM-4002 in Malaysia, contact MTM Precision.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
15 Aug 2026