Linshang LS190 vs LS192 Gloss Meter Malaysia Which Model Should You Choose?

Linshang LS190 vs LS192 Gloss Meter Malaysia Which Model Should You Choose? The Linshang LS190 and Linshang LS192 are both portable 60° gloss meters designed for surface gloss measurement, but they target different measurement requirements. The main differences are straightforward: Linshang LS190: 0200 GU measuring range with 1 GU resolution. Linshang LS192: 01000 GU measuring range with 0.1 GU resolution. For Malaysian manufacturers and QA/QC teams, understanding these differences can help avoid paying for specifications that are not requiredor choosing an instrument that does not provide enough measurement capability. LS190 vs LS192 at a Glance SpecificationLinshang LS190Linshang LS192Measurement Geometry60°60°Measuring Range0200 GU01000 GUResolution1 GU0.1 GUPositioningCost-effective routine QCWider range and finer resolution The biggest purchasing decision therefore comes down to range and resolution. Why Choose the Linshang LS190? The LS190 is designed as an economical gloss meter for routine industrial inspection. It is particularly suitable when your normal measurements fall within 0200 GU and 1 GU resolution is sufficient for the application. Typical users may include: Small and medium manufacturers Paint and coating companies Plastic manufacturers Metal fabricators Ceramic and tile companies Printing and packaging companies General QA/QC departments If the main objective is to determine whether production remains within an acceptable gloss range, the LS190 can provide a practical solution without unnecessary complexity. Why Choose the Linshang LS192? The LS192 becomes more attractive when the application requires: A much wider gloss measuring range Measurement up to 1000 GU 0.1 GU resolution Finer comparison between samples More demanding gloss measurement work The wider range also provides greater flexibility when a company measures many different products with significantly different surface gloss levels. 1 GU vs 0.1 GU Resolution Resolution is another important difference. The LS190 displays readings in 1 GU increments, while the LS192 provides 0.1 GU resolution. For example, the LS190 may display: 72 GU A higher-resolution instrument may provide a reading such as: 72.4 GU Does every factory need the extra decimal place? No. If your QC requirement simply specifies an acceptable range such as 6580 GU, the LS190 may already provide sufficient information. However, if small gloss differences are important to your process or customer specification, the LS192's finer resolution may be more appropriate. 0200 GU vs 01000 GU The same principle applies to measurement range. A larger number is not automatically better for every buyer. If all your products normally measure below 150 GU, a 01000 GU instrument may provide capability that is rarely used. On the ther hand, companies dealing with a broad variety of surfaces may prefer the flexibility of the LS192. Before buying, test or estimate the normal gloss range of your products. Choose According to the Application A simple way to decide is: Choose LS190 if: You need an affordable 60° gloss meter for routine production QC. Your expected readings are within 0200 GU. 1 GU resolution is sufficient. You mainly want to compare production batches, approved samples and QC limits. Choose LS192 if: You require a wider measurement range. You need measurements up to 1000 GU. You require 0.1 GU resolution. You handle a wider variety of surface gloss levels or need finer numerical comparison. Example: Paint Factory Suppose a paint manufacturer produces coated panels that normally measure between 60 and 90 GU. Its internal specification may be: 75 ± 5 GU For routine PASS / FAIL checking, the LS190 may already be sufficient. There may be little practical advantage in purchasing a 01000 GU meter if the factory never approaches that range. Example: Multi-Product Manufacturer Consider another manufacturer producing: Matte components Semi-gloss plastic parts Glossy coated products Highly reflective finished surfaces Because the company deals with a much broader range of products, the LS192's wider 01000 GU capability may provide more flexibility. Example: Fine Quality Comparison A company may need to investigate small differences between approved samples and new production. If distinguishing readings such as: 72.1 GU 72.6 GU 73.0 GU is important to the application, the LS192's 0.1 GU resolution is more suitable. If the company only needs to determine whether a product is approximately 72 GU or 85 GU, the LS190 may be sufficient. Do Not Buy Specifications You Do Not Need Industrial instrument purchasing should be application-driven. A higher-specification instrument is valuable when the additional capability solves a real measurement requirement. Otherwise, it simply increases investment. For many routine factory QC applications, an economical gloss meter can be the smarter choice. For more demanding measurement requirements, moving to a higher-specification model makes sense. Which Is Better for Malaysian SMEs? For many SMEs introducing gloss measurement for the first time, the Linshang LS190 is a logical starting point. It provides the essential function required to move from subjective visual inspection toward numerical gloss measurement. Companies with more demanding requirements can consider the LS192. This creates a simple selection strategy: Routine QC → LS190 Wider range / finer resolution → LS192 Applications for Both Models Depending on the measurement requirement, these instruments can be considered for: Paint and coatings Plastics Metal surfaces Ceramics Tiles Stone Paper Printing Packaging Furniture Automotive components General industrial QC Always confirm the required measurement geometry, range and resolution before selecting a model. Conclusion The choice between the Linshang LS190 and LS192 Gloss Meter should be based on actual measurement requirements rather than simply choosing the model with the higher specifications. The LS190 is the more economical choice for routine 60° gloss measurement from 0200 GU with 1 GU resolution. The LS192 is better suited to users requiring a 01000 GU range and finer 0.1 GU resolution. For many Malaysian factories performing straightforward production QC, the LS190 provides an excellent balance between functionality and cost. For applications requiring greater measurement flexibility or finer numerical detail, the LS192 is the more appropriate choice. Contact MTM Precision MTM Precision Sdn. Bhd. Showroom & Service Centre No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia 🌐 Website: www.mtmpre.com.my 📧 Email: mtmpre@yahoo.com 📱 WhatsApp: +6016-660 7346

15 Aug 2026