How to Use Myzox CL-28 CL-36 Auto Level for Site Leveling Malaysia

How to Use Myzox CL-28 CL-36 Auto Level for Site Leveling Malaysia

 

The Myzox CL-28 and CL-36 Auto Levels are optical automatic levels designed for construction surveying, civil engineering and elevation measurement work.

 

For contractors and site teams, knowing how to correctly set up and use an auto level is just as important as selecting the right instrument. Good field procedures can help reduce measurement errors and improve the reliability of leveling results.

 

MTM Precision Sdn. Bhd. is an authorized distributor of Myzox in Malaysia, supplying Myzox surveying instruments and accessories for professional users.

 

What Do You Need for Auto Leveling?

 

A typical leveling setup requires:

 

Myzox CL-28 or CL-36 Auto Level

 

Suitable surveying tripod

 

Leveling staff

 

Known benchmark or reference elevation

 

Field book or data-recording method

 

The benchmark provides the known elevation from which other site elevations can be determined.

 

Step 1: Set Up the Tripod

 

Position the tripod on stable ground.

 

Spread the tripod legs sufficiently to create a stable platform and firmly secure each leg.

 

Avoid placing the tripod on:

 

Loose soil

 

Unstable material

 

Moving platforms

 

Soft surfaces where legs may gradually sink

 

A stable setup is essential because instrument movement can affect the observations.

 

Step 2: Mount the Myzox Auto Level

 

Carefully mount the CL-28 or CL-36 onto the tripod and secure it correctly.

 

Check that the instrument is firmly attached before beginning the leveling procedure.

 

Avoid excessive force when tightening the mounting screw.

 

Step 3: Roughly Level the Instrument

 

Use the leveling screws and bubble to bring the instrument into its appropriate setup position.

 

The Myzox CL series has a specified self-leveling range of ±15′.

 

The automatic compensating mechanism works within its designed range, but the operator should still perform proper initial leveling.

 

Step 4: Focus the Telescope

 

Point the telescope toward the leveling staff.

 

Adjust the eyepiece and focusing system until the crosshairs and staff graduations appear clear.

 

Proper focusing is important for reliable staff readings.

 

The Myzox CL-28 and CL-36 both have a minimum focusing distance of approximately 0.4 m, providing flexibility for shorter-distance observations.

 

Step 5: Take a Backsight Reading

 

Position the leveling staff vertically on a known benchmark.

 

Observe the staff through the telescope and record the reading.

 

This first observation is commonly called the backsight.

 

If the benchmark elevation is known, the Height of Instrument can be determined using:

 

Height of Instrument = Benchmark Elevation + Backsight Reading

 

Step 6: Take a Foresight Reading

 

Move the leveling staff to the point where the elevation needs to be determined.

 

Observe and record the new staff reading.

 

The elevation of the new point can then be calculated using:

 

Point Elevation = Height of Instrument − Foresight Reading

 

This basic principle allows elevations to be transferred from one point to another.

 

Example of a Simple Level Calculation

 

Assume:

 

Benchmark Elevation: 100.000 m

Backsight Reading: 1.250 m

 

Therefore:

 

Height of Instrument = 101.250 m

 

If the foresight reading at the new point is:

 

1.850 m

 

Then:

 

New Point Elevation = 101.250 − 1.850

 

New Point Elevation = 99.400 m

 

This is a simplified example. Actual project procedures should follow the required surveying method and engineering specifications.

 

CL-28 or CL-36 for Site Leveling?

 

Both models operate using the same general leveling principle.

 

The primary differences are their magnification and specified accuracy.

 

Myzox CL-28

 

28X magnification

 

36 mm objective aperture

 

0.4 m minimum focusing distance

 

±2.0 mm accuracy for 1 km double-run leveling

 

The CL-28 is suitable for general construction and routine site leveling.

 

Myzox CL-36

 

36X magnification

 

36 mm objective aperture

 

0.4 m minimum focusing distance

 

±1.0 mm accuracy for 1 km double-run leveling

 

The CL-36 is suitable when higher magnification or greater specified leveling accuracy is preferred.

 

Common Auto Leveling Mistakes

 

Even a good surveying instrument can produce unreliable results if it is used incorrectly.

 

Common mistakes include:

 

Unstable Tripod Setup

 

If the tripod moves during observation, staff readings may be affected.

 

Leveling Staff Not Vertical

 

A tilted staff can introduce measurement error. The staff should be held vertically during observations.

 

Poor Focusing

 

Make sure the crosshairs and leveling staff are properly focused before taking a reading.

 

Excessive Sight Distance

 

Very long observation distances can make accurate staff readings more difficult, especially under poor atmospheric conditions.

 

Unequal Sight Distances

 

Where the leveling procedure requires it, keeping backsight and foresight distances reasonably balanced can help reduce certain systematic errors.

 

Recording Errors

 

Incorrectly recording a staff reading can invalidate otherwise good field measurements.

 

Always check important readings before leaving the measurement point.

 

Where Can the Myzox CL Series Be Used?

 

The Myzox CL-28 and CL-36 can support applications including:

 

Building construction

 

Foundation leveling

 

Road works

 

Drainage projects

 

Earthworks

 

Infrastructure construction

 

Landscaping

 

Benchmark transfer

 

Elevation checking

 

General civil engineering

 

Frequently Asked Questions

 

Is an auto level difficult to use?

 

The basic principle is straightforward, but operators should understand proper leveling procedures and field practices before relying on measurements for critical construction work.

 

Does an auto level automatically calculate elevation?

 

No. The CL-28 and CL-36 are optical automatic levels. Staff readings are observed through the telescope, and elevations are calculated or recorded separately.

 

What does “automatic” mean in an auto level?

 

It refers to the internal compensating mechanism that helps establish a horizontal line of sight after the instrument has been properly set up within its operating range.

 

Which is better for longer-distance observation?

 

The CL-36 has 36X magnification, compared with 28X for the CL-28, making it the higher-magnification option.

 

Should an auto level be checked regularly?

 

Yes. Surveying instruments used on construction sites should be inspected periodically and checked whenever accuracy is in doubt, particularly after impact, transportation or intensive field use.

 

Myzox CL-28 & CL-36 Auto Level Malaysia

 

MTM Precision supplies Myzox CL-28, CL-36 and professional surveying accessories in Malaysia.

 

As an authorized distributor of Myzox in Malaysia, we support contractors, engineers, surveyors and construction companies looking for suitable surveying instruments for their projects.

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd.

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Website: www.mtmpre.com.my

Email: mtmpre@yahoo.com

WhatsApp: +6016-6607346

 

Contact MTM Precision for enquiries about the Myzox CL-28, CL-36 Auto Level and professional surveying equipment in Malaysia.


 

16 Aug 2026