What Does -25 mm Prism Constant Mean for Myzox Monitoring Prism Malaysia

What Does -25 mm Prism Constant Mean?

 

When using a prism with a total station, prism constant is an important setting that should not be overlooked.

 

The Myzox TK-10S / TK-10 Monitoring Prism L-Bar Type has a specified prism constant of -25 mm.

 

For surveyors carrying out structural movement, deformation or construction monitoring, using the correct prism constant helps maintain consistent distance measurements across repeated observations.

 

MTM Precision Sdn. Bhd. is an authorized distributor of Myzox in Malaysia.

 

What Is a Prism Constant?

 

A surveying prism reflects the total station's EDM signal back toward the instrument.

 

Because the optical measurement path through the prism does not necessarily correspond exactly to the physical reference point of the prism assembly, a correction value is used.

 

This value is commonly known as the prism constant or prism offset.

 

Different prism designs may have different specified constants.

 

Myzox TK-10S / TK-10 Prism Constant

 

For the Myzox TK-10S / TK-10:

 

Prism Constant: -25 mm

 

This value should be considered when configuring the total station for measurements to this monitoring prism.

 

Surveyors should follow the total station manufacturer's operating procedure when entering or selecting the prism constant.

 

Why Is the Correct Prism Constant Important?

 

If the wrong prism constant is used, a systematic offset can be introduced into measured distances.

 

For ordinary work this is undesirable.

 

For deformation monitoring, where measurements from different dates are compared, maintaining consistent instrument and target settings is particularly important.

 

Before beginning a monitoring survey, operators should therefore verify:

 

Correct prism type

 

Correct prism constant

 

Correct total station settings

 

Monitoring point identification

 

Survey control

 

Observation procedure

 

These checks reduce avoidable inconsistencies between measurement sessions.

 

Example: Wrong Prism Setting

 

Consider a monitoring network containing several fixed prisms.

 

The survey team establishes baseline measurements using the correct prism configuration.

 

During a later observation, an incorrect prism constant is selected on the total station.

 

Even if the physical monitoring points have not changed, the distance results may contain an offset caused by the incorrect setting.

 

This could complicate comparison with the original baseline.

 

For monitoring work, equipment configuration should therefore be documented and checked before each observation campaign.

 

Does -25 mm Mean the Structure Has Moved 25 mm?

 

No.

 

The -25 mm value is the prism constant of the Myzox monitoring prism. It is not a measurement of structural displacement.

 

This distinction is important.

 

Prism constant relates to the optical measurement configuration between the total station and prism.

 

Structural movement is determined by comparing properly measured monitoring data over time.

 

Is Every Survey Prism -25 mm?

 

No.

 

Different prisms can have different prism constants.

 

Depending on the manufacturer and prism design, the specified constant may vary.

 

Surveyors should never assume that every prism uses the same setting simply because the prisms look similar.

 

Always check the specification for the actual prism being used.

 

Can Different Prism Types Be Used in the Same Monitoring Project?

 

Potentially, but careful measurement management is required.

 

If different prism models have different constants, the total station settings must correspond to the target being observed.

 

For long-term monitoring, using consistent prism models across the monitoring network can simplify field procedures and reduce the possibility of configuration mistakes.

 

The final equipment arrangement should follow the project's surveying requirements.

 

Why Monitoring Projects Need Consistency

 

Deformation monitoring is based on comparison.

 

For example:

 

Baseline Measurement → Observation 2 → Observation 3 → Observation 4 → Observation 5

 

If equipment configuration changes between these observations, it may become harder to determine whether a difference comes from actual target movement or from the measurement setup.

 

Consistency should therefore be maintained wherever practical in:

 

Prism model

 

Prism constant

 

Total station

 

Survey control

 

Observation procedure

 

Instrument setup

 

Target identification

 

Data processing method

 

Myzox TK-10S / TK-10 Specifications

 

SpecificationDetailsModelsTK-10S / TK-10TypeMonitoring Prism L-Bar TypePrism Diameter1 inch / 25 mmPrism Constant-25 mmPrism Height60 mmBeam Deviation5″DimensionsH90 × W86.5 × D30 mmWeightApprox. 207 gAdjustmentX/Y direction

 

The product is designed for fixed monitoring applications where the same target may be observed repeatedly.

 

Applications of Myzox Monitoring Prism

 

The TK-10S / TK-10 can support total station monitoring applications such as:

 

Building movement monitoring

 

Structural deformation monitoring

 

Retaining wall monitoring

 

Deep excavation monitoring

 

Bridge monitoring

 

Slope monitoring

 

Infrastructure monitoring

 

Construction monitoring

 

Prism Constant and Total Station Calibration Are Different

 

Prism constant and total station calibration should not be confused.

 

Prism constant relates to the prism being used and the corresponding EDM correction setting.

 

Instrument calibration involves checking and, where applicable, adjusting or verifying the performance of the surveying instrument.

 

For precision monitoring work, both correct prism configuration and properly maintained surveying equipment are important.

 

Before Starting a Monitoring Survey

 

A practical pre-measurement check may include:

 

Confirm the prism model.

 

Confirm the prism constant.

 

Check total station configuration.

 

Verify survey control points.

 

Confirm monitoring point IDs.

 

Check prism mounting.

 

Check prism orientation.

 

Confirm clear line of sight.

 

Record the observation conditions.

 

Follow the project's established monitoring procedure.

 

Good field discipline becomes increasingly important when measurements are repeated over weeks or months.

 

Why Choose a Dedicated Monitoring Prism?

 

A dedicated monitoring prism such as the Myzox TK-10S / TK-10 provides a fixed optical target for repeated observations.

 

Its monitoring-focused design includes:

 

Compact 1-inch prism

 

-25 mm prism constant

 

L-bar mounting configuration

 

X/Y directional adjustment

 

Anti-drop structure

 

Waterproof sealing design

 

Compact installation footprint

 

This makes it suitable for permanent or semi-permanent monitoring locations.

 

Myzox Monitoring Prism Supplier in Malaysia

 

MTM Precision supplies Myzox surveying equipment, monitoring prisms and total station accessories in Malaysia.

 

We support land surveyors, engineering consultants, contractors and monitoring teams requiring professional surveying equipment for construction and deformation monitoring projects.

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd.

Myzox Authorized Distributor in Malaysia

 

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Website: www.mtmpre.com.my

Email: mtmpre@yahoo.com

WhatsApp: +6016-6607346

 

Contact MTM Precision for Myzox TK-10S / TK-10 Monitoring Prism price, availability and technical enquiries in Malaysia.


 

18 Aug 2026