How to Measure Temperature and Humidity Correctly with TASI TA622C Malaysia
Using a professional temperature and humidity meter is straightforward, but measurement technique can significantly affect the usefulness of the reading.
Even a good thermo-hygrometer may give an unrepresentative result if the probe is held too close to the operator, moved rapidly between different environments, positioned directly against a surface or read before the sensor has stabilised.
The TASI TA622C Digital Thermo-Hygrometer uses a separate temperature and humidity probe and provides temperature, relative humidity, dew point and wet bulb temperature.
This guide explains how to obtain more meaningful environmental measurements when using the TA622C for HVAC, warehouse, data centre, laboratory, building maintenance and industrial applications in Malaysia.
1. Understand What You Are Trying to Measure
Before taking a reading, define the measurement objective.
Are you checking:
General room conditions?
An air-conditioning outlet?
A warehouse storage rack?
A server rack inlet?
A suspected humid area?
Conditions near a cold surface?
Differences between two rooms?
Environmental changes over time?
The correct probe location depends on the question you are trying to answer.
2. Do Not Automatically Measure Where You Are Standing
A common mistake is to enter a room, hold the meter in front of your body and assume the reading represents the whole room.
Environmental conditions may vary significantly within the same space.
Possible differences can occur:
Near doors
Near windows
At different heights
Near HVAC outlets
Behind equipment
Around machinery
Between storage racks
Near external walls
Take measurements at locations relevant to the problem being investigated.
3. Use the TA622C Separate Probe Properly
One of the practical advantages of the TASI TA622C is its separate temperature and humidity probe.
Instead of positioning the entire meter at the measurement point, place the probe where you want to measure.
This can be useful around:
Ceiling diffusers
Return air grilles
Warehouse racks
Server racks
Equipment cabinets
Storage shelves
Restricted areas
Keep the main display where it can be read comfortably.
4. Keep the Probe Away from Your Body
Your body produces heat and moisture.
Breathing can also increase humidity around the sensor.
Holding a humidity sensor directly in front of your face or very close to your hand may influence the local measurement.
Where practical, use the separate probe to maintain some distance between the sensing element and the operator.
This is particularly important when comparing small environmental differences between locations.
5. Allow the Reading to Stabilise
Do not expect an environmental sensor to instantly represent a new location after moving it from one condition to another.
For example:
Air-conditioned office → outdoor environment
Outdoor environment → cold room
Normal room → HVAC supply outlet
The sensor requires time to respond to the new temperature and humidity conditions.
Wait until the reading becomes sufficiently stable before recording or comparing the measurement.
6. Avoid Unintended Contact with Surfaces
The TA622C is being used here to measure environmental air conditions.
Do not unintentionally press the humidity probe against:
Walls
Metal surfaces
Pipes
Equipment
Your hand
Packaging
unless the manufacturer's measurement method specifically requires such positioning.
Contact with a surface can influence the local temperature around the sensor.
If actual surface temperature is required, use an appropriate surface temperature measurement instrument.
7. Avoid Direct Sunlight
Direct sunlight can heat the probe and affect the temperature measurement.
For ambient environmental measurements, avoid exposing the sensor directly to sunlight unless that is specifically part of the measurement objective.
The same principle applies to strong radiant heat sources.
8. Consider Airflow
Airflow can affect environmental measurements.
When checking HVAC systems, the airflow itself may be exactly what you want to measure.
However, when measuring general room conditions, placing the probe directly in front of an air-conditioning outlet may not represent the overall room environment.
This is why the measurement location must match the measurement objective.
9. Take Measurements at Multiple Locations
One measurement point may not represent an entire facility.
For example, in a warehouse you may compare:
Loading bay
Lower rack
Upper rack
Warehouse centre
Corner
Air-conditioned area
In a data centre you may compare:
Rack inlet
Rack exhaust
Hot aisle
Cold aisle
Different rack heights
Multiple measurements can reveal environmental differences that a single reading cannot.
10. Measure at Consistent Locations When Comparing
If you are comparing conditions over time, try to use a consistent measurement method.
For example, record measurements at:
The same location
Similar height
Similar probe position
Similar distance from HVAC outlets
Changing the measurement location can make trend comparisons less meaningful.
11. Understand Temperature Measurement
The TASI TA622C has a specified temperature measurement range of:
-40°C to 80°C
with specified temperature accuracy of:
±0.5°C
Remember that the displayed air temperature is the temperature at the probe location.
It is not automatically the temperature of a nearby wall, pipe or equipment surface.
12. Understand Relative Humidity Measurement
The TA622C has a specified relative humidity measurement range of:
0 to 100%RH
with specified accuracy of:
±3%RH within 10–90%RH.
Relative humidity is temperature-dependent.
Therefore, when investigating humidity, always consider the temperature measurement together with RH.
13. Use Dew Point When Investigating Condensation
The TA622C provides dew point temperature.
This can be particularly useful when investigating:
Condensation around HVAC outlets
Cold pipes
Windows
Cold room areas
Metal surfaces
Building moisture complaints
If a surface becomes sufficiently cold relative to the measured dew point, condensation may become possible.
For a more complete investigation, an appropriate surface temperature instrument may also be required.
14. Use Wet Bulb for HVAC Applications
The TA622C also provides wet bulb temperature.
Wet bulb information is useful for understanding the relationship between temperature, moisture and evaporative cooling.
HVAC technicians can use wet bulb together with:
Air temperature
Relative humidity
Dew point
when evaluating environmental conditions.
15. Use MAX / MIN / AVG
Environmental conditions may fluctuate during an inspection.
The TA622C provides:
MAX
MIN
AVG
These functions can help users identify:
Highest reading
Lowest reading
Average reading
during a measurement period.
This provides more information than relying only on the current display.
16. Use Data Recording for Changing Conditions
Some problems do not appear during a short inspection.
For example:
Warehouse humidity rises in the afternoon
HVAC performance changes during peak occupancy
Server room temperature increases under load
Cold room conditions change when doors open
Building humidity changes during rain
The TA622C provides data recording capability.
This allows environmental changes to be reviewed over a period rather than relying only on one spot reading.
17. Use USB PC Communication When Required
The TA622C supports USB PC communication.
This can be useful when recorded measurements need to be reviewed on a computer.
For professional users, this provides a more structured workflow than manually writing every reading.
18. Do Not Confuse Air Temperature with Surface Temperature
This is especially important for condensation troubleshooting.
The TA622C measures environmental air conditions at its probe.
If you need the actual temperature of:
Wall
Pipe
Window
Metal panel
Equipment casing
you may need an appropriate infrared thermometer or contact thermometer.
Comparing surface temperature with environmental dew point can provide useful information when investigating condensation.
19. Do Not Confuse Air Humidity with Material Moisture
Another common mistake is using a thermo-hygrometer to determine whether a wall or material is wet.
The TA622C measures relative humidity in the air.
A material moisture meter is designed for measuring or evaluating moisture in materials, depending on the model.
For building moisture investigations, both types of instruments may be required.
20. Record Measurement Location, Not Just the Number
For professional inspection, writing:
Temperature: 25.2°C
RH: 68%
may not be enough.
A better record includes the location:
Warehouse Rack A – Lower Level
Warehouse Rack A – Upper Level
Loading Bay
HVAC Supply Area
This makes measurements much easier to interpret later.
21. Compare Measurements Under Similar Conditions
When comparing two locations, avoid unnecessary differences in measurement technique.
For example, do not compare:
One probe in direct sunlight
Another probe in shade
or:
One probe directly in HVAC airflow
Another in still room air
unless those differences are intentionally part of the investigation.
22. Calibration Matters for Professional Work
For general troubleshooting, routine instrument checks may be sufficient according to your internal procedures.
For quality-controlled, audited or regulated applications, users should consider:
Calibration requirements
Calibration interval
Internal SOP
Customer requirements
Applicable standards
Measurement uncertainty
The appropriate calibration arrangement depends on the application.
Common Temperature Humidity Measurement Mistakes
Avoid these common errors:
Reading immediately after entering a new environment
Holding the probe too close to your body
Breathing directly onto the humidity sensor
Assuming one point represents the whole room
Measuring in direct sunlight unintentionally
Confusing RH with material moisture
Confusing air temperature with surface temperature
Ignoring dew point when investigating condensation
Comparing readings taken at inconsistent locations
Choosing a meter based only on display resolution
Correct technique is just as important as choosing the right instrument.
Frequently Asked Questions
How long should I wait before reading a humidity meter?
Allow sufficient time for the reading to stabilise after moving the probe into a different environment. The required time depends on the size of the environmental change and measurement conditions.
Should I hold the humidity probe close to my face?
No. Body heat and breathing may influence the local measurement.
Can TASI TA622C measure wall moisture?
No. TA622C measures environmental air temperature and humidity. A suitable material moisture meter should be used for material moisture applications.
Can TA622C measure surface temperature?
It is primarily an environmental temperature and humidity instrument. Use an appropriate surface thermometer when dedicated surface temperature measurement is required.
Can TA622C measure dew point?
Yes.
Can TA622C measure wet bulb temperature?
Yes.
Can TA622C record measurements?
Yes. It provides data recording capability.
Can recorded data be transferred to a PC?
Yes. TA622C supports USB PC communication.
Looking for a Professional Temperature & Humidity Meter in Malaysia?
MTM Precision supplies professional temperature humidity meters, thermo-hygrometers, dew point meters, data loggers, moisture meters and environmental testing instruments in Malaysia.
If you are looking for the TASI TA622C Digital Thermo-Hygrometer for HVAC, warehouse, data centre, laboratory, building maintenance or industrial environmental inspection, contact MTM Precision.
We can help you select the appropriate measurement instrument according to what you need to measure.
Contact MTM Precision
MTM Precision Sdn Bhd
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Website: www.mtmpre.com.my
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
26 Aug 2026