Why Is My Indoor Humidity So High? How to Check with TASI TA622C Malaysia

High indoor humidity is a common concern in Malaysia, particularly in air-conditioned buildings, warehouses, hotels, offices, laboratories and commercial facilities.

 

People may notice symptoms such as condensation, a damp feeling, musty conditions or unusually high relative humidity readings.

 

However, before assuming that the air-conditioning system is faulty or that the building has a moisture problem, it is useful to measure actual environmental conditions at several locations.

 

The TASI TA622C Digital Thermo-Hygrometer measures temperature, relative humidity, dew point and wet bulb temperature and uses a separate measurement probe, making it useful for investigating high indoor humidity.

 

Why Can Indoor Humidity Be High in Malaysia?

 

Malaysia has a warm and humid tropical climate.

 

Indoor humidity can therefore be influenced by both internal and external conditions.

 

Possible factors include:

 

Humid outdoor air entering the building

 

Frequent door opening

 

Poor ventilation control

 

Air-conditioning operation

 

HVAC system condition

 

Building air leakage

 

High occupancy

 

Moisture-producing activities

 

Rainy weather

 

Temperature changes

 

High humidity does not automatically mean there is one specific fault.

 

Measurements should be used together with building and HVAC inspection.

 

First Step: Measure Actual Relative Humidity

 

Descriptions such as:

 

“The room feels humid.”

 

or:

 

“The warehouse feels damp.”

 

are useful observations, but they are subjective.

 

The first step is to obtain an actual relative humidity reading.

 

The TASI TA622C measures:

 

0 to 100%RH

 

with specified humidity accuracy of:

 

±3%RH within 10–90%RH

 

It also measures temperature from:

 

-40°C to 80°C

 

with specified temperature accuracy of:

 

±0.5°C.

 

Why Temperature Matters

 

Relative humidity depends on temperature.

 

If air cools while its moisture content remains similar, relative humidity generally increases.

 

If the same air becomes warmer, relative humidity generally decreases.

 

Therefore, an RH reading should not be interpreted without considering the temperature at the same location.

 

The TA622C displays both temperature and RH, allowing users to evaluate them together.

 

Do Not Measure Only One Location

 

A single humidity measurement may not represent an entire building.

 

For example, one area may be affected by:

 

An external door

 

An air-conditioning outlet

 

A window

 

Poor airflow

 

Nearby equipment

 

A cold surface

 

Use a portable instrument to compare several locations.

 

This can help determine whether the problem is widespread or localised.

 

Check Near Doors and Entrances

 

Frequently opened doors can allow humid outdoor air into an air-conditioned building.

 

This may be particularly relevant to:

 

Hotel entrances

 

Warehouse loading bays

 

Retail premises

 

Office entrances

 

Production facilities

 

Compare the RH near the entrance with measurements deeper inside the building.

 

A large difference may provide useful information for further investigation.

 

Check Different Warehouse Zones

 

Warehouse humidity may vary considerably.

 

Possible measurement locations include:

 

Loading bay

 

Warehouse centre

 

Upper storage rack

 

Lower storage rack

 

External wall area

 

Air-conditioned zone

 

Non-air-conditioned zone

 

The TA622C separate probe makes it easier to check these different locations.

 

Check HVAC Supply and Return Areas

 

HVAC technicians may compare conditions around:

 

Supply air outlet

 

Return air grille

 

Room centre

 

Different HVAC zones

 

This can help determine whether environmental conditions differ significantly across the air-conditioning system.

 

The TA622C also provides wet bulb temperature, which can provide additional information for HVAC assessment.

 

Check for Condensation Conditions

 

High humidity may become particularly noticeable when condensation forms on cold surfaces.

 

Possible locations include:

 

Air-conditioning diffusers

 

Chilled water pipes

 

Windows

 

Metal surfaces

 

Cold room doors

 

Refrigeration equipment

 

The TA622C provides dew point temperature, which is useful when investigating condensation conditions.

 

How Dew Point Helps

 

Dew point indicates the temperature at which the surrounding air would become saturated under its current moisture condition.

 

If a surface becomes sufficiently cold relative to the dew point, condensation can occur.

 

For example:

 

Measured Dew Point: 19°C

 

If a nearby surface is significantly warmer than 19°C, condensation from the current environmental condition is less likely.

 

If the surface is around or below 19°C, condensation may be possible.

 

An appropriate infrared or contact thermometer can be used when actual surface temperature measurement is required.

 

High Humidity vs Water Leakage

 

These are not the same problem.

 

A high RH reading tells you about moisture conditions in the air.

 

It does not prove that water is leaking through a:

 

Roof

 

Pipe

 

Wall

 

Ceiling

 

Floor

 

Likewise, a water leak can exist even when the room's general RH does not appear unusually high.

 

If material moisture is suspected, a suitable moisture meter or further building inspection may be required.

 

High Humidity vs Damp Wall

 

The TASI TA622C is not a wall moisture meter.

 

It measures environmental air conditions.

 

For a damp wall investigation, technicians may use a combination of:

 

Thermo-hygrometer

 

Material moisture meter

 

Surface thermometer

 

Thermal imaging camera

 

Visual inspection

 

depending on the nature of the problem.

 

Why Is the TA622C Separate Probe Useful?

 

The TA622C uses a separate temperature and humidity probe.

 

This allows technicians to position the sensor at specific locations such as:

 

HVAC outlets

 

Corners

 

Storage racks

 

Server racks

 

Near doors

 

Different heights

 

Restricted areas

 

The main meter can remain in a convenient viewing position.

 

This is useful when trying to locate environmental differences within a building.

 

Check Humidity at Different Heights

 

Temperature and humidity may vary vertically within a space.

 

For example, conditions at:

 

Floor level

 

Working height

 

Upper storage rack

 

Ceiling level

 

may not be identical.

 

This can be relevant in high warehouses, server rooms and industrial facilities.

 

The separate probe provides more flexibility for comparing different measurement heights.

 

Does Air-Conditioning Always Reduce Humidity?

 

Air-conditioning can remove moisture as part of the cooling process, but actual indoor humidity depends on many factors.

 

These can include:

 

HVAC design

 

System operation

 

Cooling load

 

Outdoor air

 

Door opening

 

Occupancy

 

Ventilation

 

Building leakage

 

Equipment condition

 

Therefore, a high RH reading should be investigated systematically rather than immediately assuming one component is faulty.

 

Why Does a Cold Room Sometimes Have Condensation Outside?

 

Cold rooms create a large temperature difference between cold internal surfaces and warm humid surrounding air.

 

When humid air contacts a sufficiently cold surface, condensation may form.

 

Common locations include:

 

Door frames

 

Metal panels

 

Pipes

 

Refrigeration equipment

 

Transition areas

 

Dew point measurement can help technicians understand whether the surrounding environmental conditions support condensation.

 

Why Can a Hotel Room Feel Humid Even When It Is Cold?

 

Comfort depends on more than temperature alone.

 

A room can be cool while still having relatively high humidity.

 

Hotel engineering personnel can measure:

 

Temperature

 

Relative humidity

 

Dew point

 

Wet bulb

 

to obtain a clearer picture of the room environment.

 

This can provide more useful information than relying only on the thermostat setting.

 

Why Can a Warehouse Be More Humid in the Morning?

 

Environmental conditions can change throughout the day.

 

Possible reasons include:

 

Outdoor temperature changes

 

Overnight HVAC schedules

 

Rain

 

Door opening

 

Ventilation

 

Building temperature changes

 

This is why one afternoon spot reading may not explain a problem reported earlier in the morning.

 

Use Data Recording for Intermittent Humidity Problems

 

The TASI TA622C provides data recording capability.

 

This can be useful when humidity problems occur only at certain times.

 

For example:

 

Early morning

 

Afternoon

 

During production

 

During heavy rain

 

When HVAC is switched off

 

When loading doors are opened

 

Recorded measurements can provide more information about when the environmental change occurs.

 

The TA622C also supports USB PC communication.

 

Use MAX / MIN / AVG

 

The TA622C provides:

 

MAX

 

MIN

 

AVG

 

These functions can help technicians understand environmental variation during an inspection period.

 

For example, the current reading may be 65%RH, while the maximum recorded value may have been significantly higher.

 

This can help identify intermittent conditions.

 

What Is the Correct Indoor Humidity?

 

There is no single humidity value suitable for every building and application.

 

Acceptable limits depend on factors such as:

 

Building use

 

Stored products

 

Manufacturing process

 

Equipment

 

Comfort requirements

 

Internal SOP

 

Industry requirements

 

For professional applications, use the appropriate specification or requirement for the facility rather than applying one universal number.

 

A Practical High-Humidity Investigation

 

When investigating an indoor humidity complaint, a useful workflow is:

 

Measure temperature and RH at the complaint location.

 

Allow the probe reading to stabilise.

 

Measure other areas for comparison.

 

Check near doors and external air entry points.

 

Check HVAC supply and return areas where appropriate.

 

Review dew point if condensation is involved.

 

Measure relevant surface temperatures if required.

 

Investigate material moisture separately if a leak or damp wall is suspected.

 

Use data recording if the problem occurs intermittently.

 

Compare findings with the facility's environmental requirements.

 

This provides a more systematic approach than relying on one humidity reading.

 

Frequently Asked Questions

 

Why is my indoor humidity high?

Possible causes include humid outdoor air, HVAC operation, ventilation, building leakage, occupancy, moisture-producing activities and changing temperatures.

 

Can TASI TA622C find the cause of high humidity?

It provides environmental measurements that can support troubleshooting, but identifying the root cause may require HVAC or building inspection.

 

Does TA622C measure relative humidity?

Yes. Its specified range is 0 to 100%RH.

 

Can TA622C detect water leakage?

No. It measures environmental air conditions rather than directly detecting leaks.

 

Can TA622C measure wall moisture?

No. A suitable material moisture meter should be considered for wall or material moisture measurements.

 

Can TA622C help check condensation?

Yes. It provides temperature, RH and dew point information useful for evaluating condensation conditions.

 

Can TA622C record humidity changes?

Yes. It provides data recording capability and supports USB PC communication.

 

Looking for a Temperature Humidity Meter for High Humidity Troubleshooting in Malaysia?

 

MTM Precision supplies professional temperature humidity meters, thermo-hygrometers, dew point meters, moisture meters, data loggers and environmental testing instruments in Malaysia.

 

If you are investigating high humidity, condensation or HVAC environmental problems, the TASI TA622C Digital Thermo-Hygrometer can be used for professional portable temperature and humidity measurements.

 

Contact MTM Precision with your application, and we can help you select the appropriate environmental measurement instruments.

 

Contact MTM Precision

 

MTM Precision Sdn Bhd

 

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia.

 

Website: www.mtmpre.com.my

WhatsApp: +6016-660 7346

Email: mtmpre@yahoo.com


 

26 Aug 2026