How to Check Condensation Problems with TASI TA622C Temperature Humidity Meter Malaysia
Condensation is a common problem in air-conditioned buildings, warehouses, hotels, cold rooms, data centres and industrial facilities in Malaysia.
You may see water droplets on:
Air-conditioning diffusers
Chilled water pipes
Windows
Metal surfaces
Cold room doors
Equipment
Ceiling areas
The immediate assumption is often that there is a water leak.
However, visible moisture does not always come from leaking water.
In some cases, humid air is contacting a sufficiently cold surface and water vapour is condensing into liquid water.
The TASI TA622C Digital Thermo-Hygrometer can support condensation troubleshooting by measuring temperature, relative humidity and providing dew point temperature.
What Causes Condensation?
Air contains water vapour.
When air comes into contact with a cold surface, the air immediately around that surface cools.
If it cools sufficiently to reach saturation, water vapour can condense into liquid droplets.
The environmental parameter particularly useful for understanding this condition is dew point.
What Is Dew Point?
Dew point is the temperature at which air becomes saturated under its existing moisture conditions.
In practical troubleshooting:
Surface temperature above dew point
Condensation caused by the current air conditions is less likely.
Surface temperature near dew point
Condensation risk increases.
Surface temperature below dew point
The environmental conditions can support condensation on that surface.
This makes dew point highly useful when investigating unexplained water droplets on cold surfaces.
Simple Condensation Example
Suppose the TASI TA622C shows:
Air Temperature: 26°C
Relative Humidity: 70%RH
Dew Point: approximately 20°C
Now suppose a chilled metal surface is measured at:
17°C
Because the surface is below the surrounding air's dew point, condensation can occur on the surface.
This does not automatically mean the pipe or equipment is leaking.
Important: TA622C Does Not Measure Surface Temperature Directly
The TASI TA622C is primarily an environmental temperature and humidity instrument.
When carrying out a complete condensation investigation, technicians may also need to measure the temperature of the actual surface.
Depending on the application, this may be done using an appropriate:
Infrared thermometer
Contact thermometer
Surface temperature probe
The environmental dew point can then be compared with the surface temperature.
Step 1: Measure Air Temperature
Begin by measuring environmental temperature near the problem area.
The TA622C has a specified temperature measurement range of:
-40°C to 80°C
with specified temperature accuracy of:
±0.5°C
Do not place the probe directly against the wet surface when the objective is to measure the surrounding air.
Step 2: Measure Relative Humidity
Next, check relative humidity.
The TA622C has a specified RH measurement range of:
0 to 100%RH
with specified humidity accuracy of:
±3%RH within 10–90%RH
Higher moisture conditions can increase the dew point and therefore increase the likelihood that cold surfaces will fall below it.
Step 3: Check Dew Point
The TA622C provides dew point temperature.
This is the key environmental value for the condensation investigation.
Record the dew point near the affected area.
Do not assume the dew point is identical throughout the entire building.
Environmental conditions may vary from one location to another.
Step 4: Measure the Surface Temperature
Use an appropriate instrument to measure the temperature of the surface where condensation is occurring.
Possible surfaces include:
Chilled water pipe
Air-conditioning diffuser
Window
Metal panel
Cold room door
Equipment casing
Compare this value with the measured environmental dew point.
Step 5: Compare Surface Temperature with Dew Point
For example:
Dew Point: 19°C
Surface Temperature: 24°C
Condensation caused by current environmental conditions is less likely.
Now consider:
Dew Point: 19°C
Surface Temperature: 16°C
The surface is below the measured dew point.
Condensation is therefore physically possible under those environmental conditions.
Step 6: Check Several Locations
Do not rely on one measurement.
Compare:
Directly near the problem
A few metres away
Near an entrance
Near HVAC supply
Near HVAC return
Other similar equipment
This can help determine whether the problem is localised or related to general indoor humidity.
Why Is the TA622C Separate Probe Useful?
The TASI TA622C uses a separate temperature and humidity probe.
This is useful when condensation appears around locations such as:
Ceiling diffusers
Chilled water systems
Equipment
Storage racks
Server racks
Restricted areas
The probe can be positioned close to the investigation point while the technician keeps the main display visible.
Condensation Around Air-Conditioning Diffusers
Water droplets around an air-conditioning diffuser may have several possible causes.
One possibility is that the diffuser surface is cold while the surrounding air has a relatively high dew point.
If the diffuser temperature falls below the dew point, condensation can form.
Other possible causes may involve HVAC or building issues, so environmental measurements should form part of a broader inspection.
Condensation on Chilled Water Pipes
Chilled water pipes can operate at temperatures well below surrounding room temperature.
Insulation is therefore important.
If:
Insulation is damaged
Insulation is incomplete
Vapour barriers are compromised
Cold metal is exposed
humid air may contact a sufficiently cold surface and condensation can occur.
Measuring room dew point helps technicians understand the environmental side of the problem.
Condensation on Windows
Air-conditioned indoor spaces may have windows that become cold enough for condensation under certain environmental conditions.
Depending on temperature differences and moisture conditions, condensation may appear on one side of the glass.
Measure:
Nearby air temperature
Relative humidity
Dew point
and, if required, the window surface temperature.
Cold Room Condensation
Cold rooms are particularly prone to condensation problems because they create large temperature differences.
Warm humid air may enter when doors open.
Potential condensation areas include:
Door frame
Metal panels
Refrigeration equipment
Pipework
Transition areas
Portable dew point measurement can help technicians assess surrounding moisture conditions.
Warehouse Condensation
Warehouses may experience condensation on:
Metal products
Storage racks
Machinery
Roof structures
Cold surfaces
Environmental conditions can change because of:
Rain
Outdoor humidity
Door opening
Temperature changes
HVAC operation
A portable thermo-hygrometer can help compare different warehouse zones.
Data Centre Condensation
Data centres generally require controlled environmental conditions.
Condensation is particularly undesirable around electrical and electronic equipment.
If unusual moisture is observed, technicians may investigate:
Temperature
RH
Dew point
Cooling equipment
Local cold surfaces
Permanent monitoring systems may be used for continuous monitoring, while the TA622C can be used for portable troubleshooting at specific locations.
Condensation vs Water Leak
This distinction is important.
Condensation
Water vapour from the air changes into liquid water on a sufficiently cold surface.
Water Leak
Liquid water enters from another source, such as plumbing, roof, drainage or building envelope.
Both can produce visible water.
Environmental measurements can help determine whether condensation is physically plausible, but they do not automatically prove the absence of a leak.
Condensation vs Material Moisture
The TA622C measures environmental air conditions.
It does not measure moisture inside:
Concrete
Wallboard
Timber
Flooring
Building materials
If material moisture is suspected, a suitable moisture meter or other inspection method may be required.
Why Does Condensation Sometimes Appear Only in the Morning?
Environmental conditions change over time.
Possible factors include:
Lower overnight surface temperature
HVAC schedule
Outdoor humidity
Morning door opening
Building thermal changes
A spot measurement later in the day may therefore miss the condition that caused the condensation.
Use Data Recording for Intermittent Condensation
The TASI TA622C provides data recording capability.
This can be useful when condensation occurs only during certain periods.
Users may investigate conditions:
Overnight
Early morning
During rain
During HVAC startup
During loading operations
The TA622C also supports USB PC communication for working with recorded measurements.
Use MAX / MIN / AVG
The TA622C provides:
MAX
MIN
AVG
These functions can help technicians understand environmental variation during the investigation.
For example, current RH may look acceptable while the maximum RH during an earlier period was significantly higher.
Common Condensation Troubleshooting Mistakes
Avoid these common mistakes:
Assuming all visible water is a leak
Measuring RH but ignoring temperature
Ignoring dew point
Measuring only one location
Comparing dew point without checking surface temperature
Confusing air humidity with material moisture
Taking a reading before the probe stabilises
Measuring too close to your body
Ignoring changing conditions over time
A systematic measurement approach provides better troubleshooting information.
Practical Condensation Investigation Checklist
When investigating condensation:
Identify where water is appearing.
Measure nearby air temperature.
Measure relative humidity.
Check dew point.
Measure the affected surface temperature with an appropriate instrument.
Compare surface temperature with dew point.
Check other nearby locations.
Investigate HVAC and building conditions.
Consider water leakage separately.
Use data recording if the problem is intermittent.
This helps distinguish environmental condensation conditions from other moisture problems.
Frequently Asked Questions
Can TASI TA622C detect condensation?
It measures temperature, RH and dew point, which can help evaluate whether environmental conditions support condensation.
Can TA622C tell me whether a pipe is leaking?
No. It does not directly detect plumbing leakage.
Does TA622C measure surface temperature?
It is primarily designed for environmental measurement. A suitable surface temperature instrument may be required for direct surface measurement.
What is the most important value for checking condensation?
Dew point is particularly useful, especially when compared with the temperature of the affected surface.
Does high humidity always cause condensation?
No. Condensation depends on the relationship between moisture conditions and surface temperature.
Can condensation happen at 60%RH?
It can if a surface becomes sufficiently cold relative to the dew point. RH percentage alone does not determine whether condensation will occur.
Can TA622C record environmental conditions?
Yes. It provides data recording capability and USB PC communication.
Looking for a Dew Point Meter for Condensation Troubleshooting in Malaysia?
MTM Precision supplies professional dew point meters, temperature humidity meters, thermo-hygrometers, infrared thermometers, moisture meters, data loggers and environmental testing instruments in Malaysia.
If you are investigating condensation around HVAC systems, chilled water pipes, warehouses, cold rooms, hotels, data centres or commercial buildings, the TASI TA622C Digital Thermo-Hygrometer can provide the environmental temperature, RH and dew point information needed for a more systematic investigation.
Contact MTM Precision with your application, and we can help you identify the appropriate combination of measurement instruments.
Contact MTM Precision
MTM Precision Sdn Bhd
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Website: www.mtmpre.com.my
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
26 Aug 2026